IMS2, IMS3, IMS4, IMS5 Operator Manual
4806-00017
Revision F
33
Section 12.4: Information Screen 3
NOTICE: Switch between Information Screens 1 through 4
using the Left and Right arrow softkeys.
• Input Ovrd H: The total number of hours an input over
CAN has overridden the IMS and forced the engine to run.
• Input Ovrd C: The total number of times an input over
CAN has overridden the IMS and forced the engine to run.
• Aux1/mPTO H: The total number of hours mPTO has been
on.
• Aux1/mPTO C: The total number of times mPTO has been
selected.
• Bucket Off H: The total number of hours the boom
(if equipped) has been out of stow while in Idle Mitigation
Mode.
• Bucket Off C: The total number of times the boom
(if equipped) has been out of stow while in Idle Mitigation
Mode.
• ePto Run H: The total number of hours ePTO has been on
(if a hybrid electric motor is equipped).
• ePto Run C: The total number of times ePTO has been
selected (if a hybrid electric motor is equipped).
• Bucket Ovrd H: The total number of hours the start/stop
function has been used to disengage Idle Mitigation Mode
and start the engine.
• Bucket Ovrd C: The total number of times the start/stop
function has been used to disengage Idle Mitigation Mode
and start the engine.
• Min Batt 1 V: The lowest voltage read from Battery 1
(checks every 20 seconds and records the lowest number).
• Min Batt 2 V: The lowest voltage read from Battery 2
(checks every 20 seconds and records the lowest number).
• Min Batt1 T: The time the minimum voltage from Battery
1 was recorded (comes from CAN remote time).
• Min Batt2 T: The time the minimum voltage from Battery
2 was recorded (comes from CAN remote time).