Assembly
ZeroClamp zero point clamping system
– manual
26
Assembly on clamping units and consoles
Chuck size
Diameter A / Height
Ø 90 / 22
Ø 120 / 28
Ø 138 / 33
Ø 190 / 38
B = Pitch circle
fastening bore
Ø81 / R 40,5
Ø107 / R 53,5
Ø121 / R 60,5
Ø174,5 /
R 87,25
C = Thread size
M4-10,5 deep/
12,5 deep
M6-10,5 deep/
12,5 deep
M8-13 deep /
15 deep
M8-14 deep /
17 deep
Number of threads
8
6
6
8
D = Diameter o fair
holes
Ø3
Ø4,3
Ø4,3
Ø6
E = Air holes
41
51
62
87
F = Index bores
41
54
62
87,5
G = size
index bores
Ø6H7-10 deep
(0°, 90°, 270°)
Ø8H7
–12 deep
(0°, 120°, 240° )
Ø10H7-16 deep
(0°, 120°, 240° )
Ø10H7-16 deep
( 0°, 90°, 270°)
H =Standard depth
chuck section
18
1
24
1
19
28
I/J = Installation depth
5/22
5/28
5/33
5/38
Surface finish: Rz 6,3
For surface-flush installation
The plane surface of the clamping pot has at
least one projection of + 0.003 to 0.005 mm
to the table surface!
When the clamping pot is mounted below the mounting depth the function is no
longer guaranteed. There is a risk that the clamping can be loosen.
To balance the following spacer rings (thickness 0.01 mm) are available:
Diameter
Ø 90 mm
Ø 120 mm
Ø 138 mm
Ø 190 mm
Article no:
20700
16623
20708
on request
1
At supernatant pot +4 mm