SAFETY INSTRUCTIONS

STANDARDS TO FOLLOW 

• To ensure the safety of people, it is important that you 

read all the following instructions. Incorrect installation or 

incorrect use of the product can cause physical injury and 

material damage.

• Keep these instructions in a safe place for future refe

-

rence.

• This product was designed and produced strictly for the 

use indicated in this manual. Any other use, not expres

-

sly indicated here, could compromise the good condition/

operation of the product and/or be a source of danger.

• ZERO SRLS is not responsible for the improper use of the 

product, or other use than that for which it was designed.

• ZERO SRLS is not responsible if safety standards were 

not taken into account when installing the equipment, or 

for any deformation that may occur to it.

• ZERO SRLS is not responsible for the safety and proper 

operation when using components not sold by them.

• Do not make any modifications to the operator compo

-

nents and / or their  accessories.

•  Before  installation  unplug  the  automatism  from  the 

source of power.

• The installer must inform the client how to handle the 

product in case of emergency and provide this manual to 

user.

• Keep remote controls away from children, to prevent 

the automated system from being activated involuntarily.

•  The  customer  shall  not,  under  any  circumstances,  at

-

tempt to repair or tune the automatism. Must call quali

-

fied technician only.

• Connect the automatism to a 230V plug with ground 

wire.

• Control board for indoor use.

 

THE CONTROL BOARD

TECHNICAL SPECIFICATIONS

          

Power supply:

230V 50/60Hz

Motor’s output:

AC230V 1350 W max

Aux. accessories 

output: 

AC12V-1W- 80mA máx

Working temperature:

-20°C a +50°C

Radio Receptor:

Incorporated 433,92 Mhz

OP Transmitters:

Rolling Code

Max. memory capacity:

 

50 codes max

CONNECTOR’S DESCRIPTION

CN1 Connector

01 • LINE INPUT NEUTRAL

02 • LINE INPUT PHASE 230V

03 • MOTOR OUTPUT CLOSE

04 • MOTOR OUTPUT OPEN

05 • MOTOR COM

CN2 Connector

06 • POWER SUPPLY OUTPUT 12Vdc

07 • POWER SUPPLY OUTPUT 0Vdc

08 • PHOTOCELLS INPUT (NC) - PHOTO

09 • COM CONNECTION

10 • OPEN PUSH BUTTON (NO) - START

11 • SAFETY EDGE 8.2KOHM (NC) 

OPTION (configuration with brake relese PORTA SB)

12 • BRAKE INPUT (+12V)

13 • COM CONNECTION

14 • BATTERY (0V)

15 • BATTERY (12V) 

PROGRAMMING PRE-RECOMENDATIONS

Before  proceeding  to  the  control  board  configuration, 

note the following points listed in the table below in order 

to better understand the control board function:

Motor:

03 and 04 The motor phases must be connected in these 

two terminals. If the motor direction is the opposite to the 

desired simply switch the two wires to reverse direction.

Security circuit - Photocells:

09 (COM) and 08  This circuit allows connection of all pho

-

tocells types. This device intervenes only during closure. 

In pause time When it is activated during closing maneu

-

vers, it stops and starts a complete automatism opening.

Mecanic push-button:

09 (COM) and 10  This circuit allows the connection of 

mechanical  push-buttons  with  two  button  for  opening 

and closing. NOTA  You can, with a one button’s push-but

-

ton , control the opening and closing of the automation 

in step mode (open-stop-close-stop (...) always with the 

same button. 

Summary of Contents for PORTA

Page 1: ...230 CONTROL PANEL PORTA 230V zero HOME AUTOMATION USER MANUAL AND CONFIGURATION ZPORTAV230SB VER1 0 01012018_REV1 IT EN FR zero HOME AUTOMATION PORTA 8K2 SB CONTROL UNIT ROLLING SHUTTERS AWNINGS 230V made in italy ...

Page 2: ...zero HOME AUTOMATION PG2 ZPORTAV230 CONTROL PANEL PORTA 230 V zero HOME AUTOMATION ...

Page 3: ...mare il cliente su come maneg giare il prodotto in caso di emergenza e fornire questo manuale all utente Tenere i telecomandi lontani dai bambini per evitare che il sistema automatizzato venga attivato involontaria mente Il cliente non può in nessun caso tentare di riparare o sintonizzare l automatismo Deve chiamare solo un tecni co qualificato Collegare l automatismo a una presa da 230 V con cavo...

Page 4: ...brevi segnali acustici Cancellare tutti i codici La cancellazione di tutti i codici è ottenuta dal reset della memoria Premere PROG per 6 secondi Si produrrà una raffica di luci rosse lampeggianti e un breve segnale acustico che indica la cancellazione di tutti i codici memo rizzati in precedenza Il dispositivo rimarrà nella sequenza di memorizzazione di codici in attesa di memorizzarne di nuovi I...

Page 5: ...sione comanda l apertura fino al raggiungimento fine corsa apre o allo scadere del tempo di funzionamento il secondo impulso comanda la chiusura del serramento Se si invia un impulso prima dello scadere del tempo di funzionamento la centrale effettua l arresto del moto un ulteriore comando determina la ripresa del moto in senso opposto PROGRAMMAZIONE DEI TELECOMANDI SENZA ACCESSO ALLA SCHEDA DI CO...

Page 6: ... delle fotocellule posizionare l interrut tore DIP 5 su OFF Le fotocellule di sicurezza funzionano come segue Nelle manovre di apertura non ha azione Una volta aperte le fotocellule fanno sì che la port ri manga aperta se c è un ostacolo interposta tra loro Nelle manovre di chiusura il cancello si arresta e inizia immediatamente ad aprirsi fermandosi alla fine del tem po di lavoro o alla posizione...

Page 7: ...30V plug with ground wire Control board for indoor use THE CONTROL BOARD TECHNICAL SPECIFICATIONS Power supply 230V 50 60Hz Motor s output AC230V 1350 W max Aux accessories output AC12V 1W 80mA máx Working temperature 20 C a 50 C Radio Receptor Incorporated 433 92 Mhz OP Transmitters Rolling Code Max memory capacity 50 codes max CONNECTOR S DESCRIPTION CN1 Connector 01 LINE INPUT NEUTRAL 02 LINE I...

Page 8: ...eep indicator is on Press the new transmitter s desired opening key while led and acustic indicator signs the transmitters storage After 2 seconds elapsed since the last reception of a code the device will automatically leave the memory function by switching off the red LED and emitting two short beeps OPTION configuration with brake relese PORTA SB BRAKE TRANSMITTER RELEASE To use this function i...

Page 9: ... connector The release of the brake by radio can be carried out in the presence or absence of 230Vac power supply The release is activated by pressing the hide button on the remote control located at the rear of transmitter for 6 seconds The brake will be released for 60 seconds the time nee ded to raise the door by hand The control unit is equipped with a battery charging system and charge mainte...

Page 10: ... be changed according to the motor consumption to a maximum of 8A250V All tests must be performed by professional technicians due to serious danger associated with the misuse of electrical systems DIAGNOSIS DOOR OPENS BUT DOESN T CLOSE Put the DIP 5 and DIP 6 ON to disable the photocells Try to close the automatism If it closes the problem is in photocells If it doesn t close the problem is in the...

Page 11: ...rgence et fournir ce mode d emploi à son utilisateur Gardez toutes les télécommandes hors de la portée des enfants afin d éviter que l automatisme travail accidentellement Le client ne doit pas en aucun cas essayer de réparer ou régler la centrale Il doit à cet eet faire appel à un technicien qualifié Brancher la centrale à une prise de 230V avec le fil de terre Centrale pour une utilisation à l i...

Page 12: ...œuvre de fermeture on doit maintenir appuyé sur la touche de l émetteur ou le bouton poussoir alternatif Au contraire la manœuvre s arrête DIP 4 OFF dèshabilitée Fonctionnement normale COSTA DE SECURITÈ 8K2 DIP 5 ON and DIP 6 ON Foto y sècuritè band dèshabilitée DIP 5 ON and DIP 6 OFF Foto y sècuritè band abilitée DIP 5 OFF and DIP 6 ON abilitée securitè band 8k2 e fotocell DIP 5 OFF and DIP 6 OFF...

Page 13: ...des de l in dicateur sonore ceci indiquera qu on a annulé tous les codes auparavant mémorisés L appareil se maintiendra dans la séquence de mémorisation de codes en attente de mémoriser des nouveaux codes FEATURES Programmation du temps de fermeture automatique réglé en usine 60 sec La programmation peut avoir lieu si la porte se trouve en état de repos Une fois activée la programmation du mi cros...

Page 14: ...n de photocellules plácer le DIP switc 5 en OFF Les photocellules de sécurité fonctionne comme suit En manoeuvres d ouverture n ont pas d action Lorsqu ouvert les photocellules gardent le portail ouvert dans le cas d avoir un obstacle devant les photocellules Lors de la fermeture le portail s arrête et commence à s ouvrir dans l immédiat en s arrêtant à la fin du temps de travail ou bien à la fin ...

Page 15: ...zero HOME AUTOMATION PG15 ZPORTAV230 CONTROL PANEL PORTA 230V OPTION MODEL PORTA SB OPTION MODEL PORTA SB CONNESSIONI CONNECTIONS SCHÉMA DE RACCORDEMENTS ...

Page 16: ...zero HOME AUTOMATION PG16 ZPORTAV230 CONTROL PANEL PORTA 230 V FOTO FOTO BATTERY ...

Page 17: ...zero HOME AUTOMATION PG17 ZPORTAV230 CONTROL PANEL PORTA 230V FOTO 180 LED LAMP BULB LAMP FLASHING LIGHT CONNECTION ...

Page 18: ... 95 CE Directive e che sono state applicate tutte le norme e o specifiche tecniche di seguito indicate EN61000 6 2 EN61000 6 3 EN62233 2008 EN301489 1 EN301489 3 EN300220 2 EN60335 1 2002 ed emendamenti successivi ALTAVILLA VICENTINA VI Italia 01 07 2016 Inoltre dichiara che non è consentito mettere in servizio il macchinario fino a che la macchina in cui sarà incorporata o di cui diverrà compo ne...

Page 19: ...with the conditions of the 2006 42 EC Directive and with the national legislation that transpose it ANDREA MARAN ZERO SRLS Representative DECLARATION DE CONFORMITA CE Le soussigné Mr Andrea Maran rreprésentant le suivant constructeur ZERO SRL Via Roma 25 A 36077 ALTAVILLA VICENTINA ITALIA Déclare que l appareil décrit ci dessous Description Electronic control unit Modèle PORTA Est conforme aux dis...

Page 20: ...zero HOME AUTOMATION PG20 ZPORTAV230 CONTROL PANEL PORTA 230 V zero HOME AUTOMATION ZERO SRLS Via Olona 110 Gallarate VA ITALIA info miozero it www miozero it ...

Reviews: