4 • Delivery
DELIVERY
ATTENTION FORKLIFT OPERATOR!
Forks must be 48" long, 1 1/2" to 1 3/4" thick, and no more than
4" wide to fit the bases.
2 to 5-door cases and 4' to 12' open multi-
decks are fork-liftable from either end of the case. 1-door cases are
not fork-liftable through a standard doorway.
24" 2-Door Cases or 4' Open Multi-Decks:
Forks must extend 20" to 24" under the case.
30" 2-Door or 24" 3-Door Cases or 6' Open Multi-Decks:
Forks must extend 26" to 30" under the case.
30" 3-Door or 24" 4-Door Cases or 8' Open Multi-Decks:
Forks must extend 39" to 43" under the case.
30" 4- & 5-Door or 24" 6-Door Cases or 12' Open Multi-Decks:
Forks must extend 44" to 47" under the case.
1. Remove the upper electrical box by disconnecting
the 3 wiring connectors, then remove the 4 screws
that attach the electrical box to the top of the case.
2. Remove the piping bracket from the back of the
case.
3. Pull quick-connect lines away and down from the
case.
4. Once inside, reposition quick-connect lines,
reinstall bracket, and set electrical box on top.
Do not leave, store, or hold case outdoors in direct sunlight or high ambient temperature. With the end panels on, a display case
with doors will be airtight; the inside temperature of the case will increase, and the heat will be unable to escape. This could
potentially cause any plastic (such as PTM) inside the case to melt.
TO GET THROUGH A DOORWAY, IT MAY BE NECESSARY TO TEMPORARILY DISMOUNT THE REFRIGERATION
LINES AND THE TOP ELECTRICAL BOX.
Temperature
Probe Wires
Note: Set the case at least 3" away from the wall to allow for air circulation and piping. A 3" standard (or 6" optional) standoff spacer
is required between the rear wall and the case.
Moving Display Case
Piping Bracket