background image

 

13

 

 
ZERICA srl 

Zona Industriale 
90018 Termini Imerese (Pa) - Italy 
Tel. +39.091.8140341 – 091.8140377 – 091.8167962 – 091.9293333   Fax +39.091.8140364 
http://www.zerica.com  e-mail:[email protected] 

Total or partial reproduction is forbidden. The manufacturer disclaims any responsibility for any typographical errors 
included in this manual.  It reserves the right to make amendments to own products considered necessary or useful 
withou jeopardising their functional features, without prior notice. 
 

(300)

 

 
 
 
 
 

Summary of Contents for REFRESH P HPDC

Page 1: ...for which it has been designed as well as safe in compliance with applicable standards The reproduction of the contents of this manual for distribution to third parties is strictly forbidden without the express prior consent of the manufacturer Zerica S r l This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experienc...

Page 2: ...a gap of at least 5 cm on each side and 25 cm by the ventilation slots If the ventilation slots are covered the cooling system cannot operate properly and this inevitably leads to malfunctioning Do not place any objects on top of the product Caution non compliance with the above conditions causes the compressor to overheat and break leading to immediate invalidation of the warranty For proper inst...

Page 3: ...id connection A dust cap may be present if so it is necessary to remove it before water tube connection The incoming water pressure must be between 0 250 MPa e 0 500 MPa The flow rate should not be less than 3 litres minute Check that the pressure remains constant even while water is being dispensed or at least that variations do not exceed 0 050 MPa If this is not the case reduce the length of th...

Page 4: ...4 R C column tap Screw with care the tube to the inferior part of the tap without moving the black lever from place ...

Page 5: ...ust be grounded in compliance with applicable standards and laws In case of malfunctioning grounding reduces the risk of electrical shocks Connect the appliance cable to a double pole switch with a minimum of at least 3 mm distance between the contacts or using a plug which must still be accessible after installation 080 USING THE PRODUCT FOR THE FIRST TIME When you first use the product in order ...

Page 6: ...tion slots Periodically check that the ventilation slots are clear and not obstructed then remove any impurity deposited on the ventilation slots using a brush or a vacuum cleaner CAUTION Failure to clean the condenser and poor ventilation of the cooling circuit can cause the compressor to overheat and break These causes invalidate the WARRANTY and any repair cost will be charged 130 WATER CIRCUIT...

Page 7: ...AINTENANCE CHART Date of installation Customer Address Tel Installation company Model SERIAL NO RESPECT MAINTENANCE DATES DURING WARRANTY see warranty clauses Date Litres Replaced parts Service centre 200 ...

Page 8: ...e number and a description of the problem and in any event by filling out the RMA form Transport costs shall be borne by the purchaser You can get more information by contacting ZERICA S r l at the address below There may be delays in the repair or replacement of components that are found to be faulty at source in the event that they are not in stock The warranty excludes those products that I in ...

Page 9: ...9 ...

Page 10: ...ts Section 2 Limits for harmonic current emissions equipment input current less than 16A per phase CEI EN 61000 3 3 2014 o Electromagnetic compatibility Part 3 Limits Section 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current less than 16A and not subject to conditional connection Declares under its responsibility that this product Compl...

Page 11: ...lab in Modena HPDC system consisting of food grade copper components Test Report No 1201 09 issued on 11 May 2009 by G R Biochemilab in Modena Plastic fittings Test Report No 51 10 AMB issued on 10 December 2010 by Bioanalisi in Erice Nickel plated brass fittings Test Report No 51 10 AMB issued on 10 December 2010 by Bioanalisi in Erice Brass fittings Test Report No 51 10 AMB issued on 10 December...

Page 12: ...12 ...

Page 13: ...p www zerica com e mail info zerica com Total or partial reproduction is forbidden The manufacturer disclaims any responsibility for any typographical errors included in this manual It reserves the right to make amendments to own products considered necessary or useful withou jeopardising their functional features without prior notice 300 ...