EC DECLARATION OF CONFORMITY 

Manufacturer: ZERICA s.r.l. 
Address: Zona Industriale – 90018 Termini Imerese (PA) 
Declares under its responsibility that this product: 
 

Complies with the requirements of EEC Directive (2006/95/EC) - low tension directive 
Complies with the requirements of EEC Directive (2004/108/EC - EMC) – electromagnetic compatibility; 
 

Electrical safety: 

 

CEI EN 60335-1 :2013-01 

o

 

Safety of electrical appliances for household and similar use. Part 1: General requirements.. 

 

CEI EN 60335-2-89/2011 

o

 

Electrical appliances for household and similar purposes - Safety. Part 2: Particular requirements for appliances for 

commercial refrigeration condensing unit of refrigerant, compressor or an incorporated or remote 

 

Electromagnetic compatibility: 

 

CEI EN 55014-1/2008+A1-2010+A2-2012 

Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus. Part 1: Emission. 
 

 

CEI EN 55014-2/1998+A1-2002+IS1-2007+A2-2009 

o

 

Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus. Part 2: Immunity. 

 

 

CEI EN 61000-3-2/2007+A1+A2-2011 Part 3-2: 

o

 

Electromagnetic compatibility. Part 3: Limits - Section 2: Limits for harmonic current emissions (equipment input current less 

than 16A per phase).  

 

CEI EN 61000-3-3/2014 

o

 

Electromagnetic compatibility. Part 3: Limits - Section 3: Limitation of voltage fluctuations and flicker in low-voltage supply 

systems for equipment with rated current less than 16A and not subject to conditional connection. 

 

Declares under its responsibility that this product: 

 

Complies  with  Directive  2011/65/CE  (RoHS  2)-  “Restricting  the  use  of  certain  hazardous  substances  in  electrical  and  electronic 

equipment” - RoHS. 

 

The carbonators used by ZERICA S.r.l. have been designed and produced according to sound engineering practice, tested according to the 

reference procedures and are suitable for use in systems for producing sparkling water, using only drinking water and CO2 at a maximum 
operating pressure of 7 bar. 

 

The carbonators are inserted in systems subject to the Machinery Directive (89/392/EC) or the Low Voltage Directive (73/23/EC) and 

therefore do not fall within the scope of the Pressure Equipment Directive - PED (97/23/EC) according to the exclusions in art. 1 point 
3.6. of said Directive. 

 

In addition, the models of carbonators used by Zerica have a product PSxV below the limit established by the PED, at 50, and do not 

therefore have to be CE-marked as they come under the equipment referred to in art. 3§3 in said directive.

 

 

(230)

 

 

 
 
 
 
 
 

 

Summary of Contents for REFRESH P HPDC

Page 1: ...for which it has been designed as well as safe in compliance with applicable standards The reproduction of the contents of this manual for distribution to third parties is strictly forbidden without the express prior consent of the manufacturer Zerica S r l This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experienc...

Page 2: ...a gap of at least 5 cm on each side and 25 cm by the ventilation slots If the ventilation slots are covered the cooling system cannot operate properly and this inevitably leads to malfunctioning Do not place any objects on top of the product Caution non compliance with the above conditions causes the compressor to overheat and break leading to immediate invalidation of the warranty For proper inst...

Page 3: ...id connection A dust cap may be present if so it is necessary to remove it before water tube connection The incoming water pressure must be between 0 250 MPa e 0 500 MPa The flow rate should not be less than 3 litres minute Check that the pressure remains constant even while water is being dispensed or at least that variations do not exceed 0 050 MPa If this is not the case reduce the length of th...

Page 4: ...4 R C column tap Screw with care the tube to the inferior part of the tap without moving the black lever from place ...

Page 5: ...ust be grounded in compliance with applicable standards and laws In case of malfunctioning grounding reduces the risk of electrical shocks Connect the appliance cable to a double pole switch with a minimum of at least 3 mm distance between the contacts or using a plug which must still be accessible after installation 080 USING THE PRODUCT FOR THE FIRST TIME When you first use the product in order ...

Page 6: ...tion slots Periodically check that the ventilation slots are clear and not obstructed then remove any impurity deposited on the ventilation slots using a brush or a vacuum cleaner CAUTION Failure to clean the condenser and poor ventilation of the cooling circuit can cause the compressor to overheat and break These causes invalidate the WARRANTY and any repair cost will be charged 130 WATER CIRCUIT...

Page 7: ...AINTENANCE CHART Date of installation Customer Address Tel Installation company Model SERIAL NO RESPECT MAINTENANCE DATES DURING WARRANTY see warranty clauses Date Litres Replaced parts Service centre 200 ...

Page 8: ...e number and a description of the problem and in any event by filling out the RMA form Transport costs shall be borne by the purchaser You can get more information by contacting ZERICA S r l at the address below There may be delays in the repair or replacement of components that are found to be faulty at source in the event that they are not in stock The warranty excludes those products that I in ...

Page 9: ...9 ...

Page 10: ...ts Section 2 Limits for harmonic current emissions equipment input current less than 16A per phase CEI EN 61000 3 3 2014 o Electromagnetic compatibility Part 3 Limits Section 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current less than 16A and not subject to conditional connection Declares under its responsibility that this product Compl...

Page 11: ...lab in Modena HPDC system consisting of food grade copper components Test Report No 1201 09 issued on 11 May 2009 by G R Biochemilab in Modena Plastic fittings Test Report No 51 10 AMB issued on 10 December 2010 by Bioanalisi in Erice Nickel plated brass fittings Test Report No 51 10 AMB issued on 10 December 2010 by Bioanalisi in Erice Brass fittings Test Report No 51 10 AMB issued on 10 December...

Page 12: ...12 ...

Page 13: ...p www zerica com e mail info zerica com Total or partial reproduction is forbidden The manufacturer disclaims any responsibility for any typographical errors included in this manual It reserves the right to make amendments to own products considered necessary or useful withou jeopardising their functional features without prior notice 300 ...

Reviews: