EN
27
EN
Rated Capacity
681.4 L (180 gallons) - (for VOC)
16655.8 L (4 400 gallons) - (for Aesthetic Chlorine)
Min-Max operating pressure:
138kPa ~ 827kPa (20 psi ~ 120 psi)
Min-Max feed water temperature:
5 ºC ~ 35 ºC (41ºF ~ 95 ºF)
Rated Service Flow
0.26 L/min (0.07 GPM)
Daily Water Production Rate*
168.5 L/d (44.5 GPD)
Product Efficiency Rating*
20.7 %
Substance
Max.
Allowable
Concentration
(mg/L)
Average
Influent
(mg/L)
Average
Effluent
(mg/L)
Minimum
Percent
Reduction (%)
Average
Percent
Reduction
(%)
Arsenic (Pentavalent)
0.010
0.0511
0.001
93.9
97.8
Barium
2.0
11.4
0.309
93.1
97.3
Radium 226/228
5 pCi/L
25 pCi/L
5 pCi/L
N/A
N/A
Cadmium
0.005
0.035
0.00056
95.8
98.4
Chromium (Hexavalent)
0.1
0.324
0.00446
95.9
98.6
Chromium (Trivalent)
0.100
0.281
0.00174
98.4
99.4
Lead
0.010
0.201
0.00149
98.1
99.3
Copper
1.3
3.223
0.063
96.4
98.0
Selenium
0.05
0.121
0.00192
96.9
98.4
TDS
<187.5
751.8
57.8
91.4
92.3
Aesthetic Chlorine
≥ 50% reduction
2.07
0.56
54.53
72.8
VOC*
≥ 95% reduction
0.3274
0.0008
94.3
99.7
WATER FILTRATION SYSTEM
PERFORMANCE DATA SHEET
BRAND: ZEPTER INTERNATIONAL - MODEL: PWC-670
This system has been tested and certified by the Water Quality Association according
to NSF/ANSI 42, 53, and 58 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI, 53, and 58.
While testing was performed under laboratory conditions, actual performance may vary.
GENERAL OPERATING INFORMATION:
*Daily Water Production Rate and Product Efficiency Rating can be differentiated according to the inlet
water pressure and water temperature.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
• Refer to the owners manual for specific installation instructions, manufacturer’s
limited warranty, user responsibility, and parts and service availability.
• The influent water to the system shall include the following characteristics:
- No organic solvents
- Chlorine: < 2 mg/L
- pH: 7 - 8
- Temperature: 5 ºC ~ 35 ºC (41 ºF ~ 95 ºF)
- Iron: < 2 mg/L
- Turbidity: < 1 NTU
- Hardness: < 1 000 mg/L
• For parts and service availability, please contact your local Zepter dealer.
• This system has been tested for the treatment of water containing pentavalent
arsenic (also know as As(V), As(+5), or arsenate) at concentrations of 0.050
mg/L or less. This system reduces pentavalent arsenic, but may not remove
other forms of arsenic. This system is to be used on water supplies containing
a detectable free chlorine residual at the system inlet or on water supplies
that have been demonstrated to contain only pentavalent arsenic. Treatment
with chloramines (combined chlorine) is not sufficient to ensure complete
conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic
Facts section of this Performance Data Sheet for further information.
• Efficiency rating means the percentage of the influent water to the system
that is available to the user as reverse osmosis treated water under operating
conditions that approximate typical daily usage.
• The product water should be tested every 6 months to ensure that the
contaminants are being reduced effectively. Please contact your local Zepter
dealer. to initiate this service.
• This reverse osmosis system contains a replaceable treatment components,
critical for the effective reduction of total dissolved solids and that product
water shall be tested periodically to verify that the system is performing
properly. Replacement of reverse osmosis component should be with one of
identical specifications, as defined by the manufacturer, to assure the same
efficiency and contaminant reduction performance.
• The estimated replacement time of filter, which is a consumable part, is not
an indication of quality guarantee period, but it means the ideal time of filter
replacement. Accordingly, the estimated time of filter replacement may be shortened in
case it is used in an area of poor water quality.
Summary of Contents for Edel Wasser PWC-670-BLACK
Page 74: ...RU RU 145 Edel Wasser Edel Wasser Zepter Zepter EdelWasser 1 2 3 1 2 3...
Page 75: ...RU RU 147 5 4 1 2 4 3 4 4 1 3 4 5 1 2 1 2...
Page 76: ...RU RU 149 1 2 10 1 2 3 4...
Page 77: ...RU 151 RU 1 1 2 3 4 5 5 2 1 2 3 4 5...
Page 78: ...RU 153 RU 1 16 25 2 3 6 5 7 4 5...
Page 80: ...RU RU 157 2 3 4 1 2 3 4 30 3 3...
Page 82: ...RU RU 161 DLFC Zepter International Zepter International...
Page 83: ...163 RU RU EDEL WASSER PWC 670 BLACK PWC 670 ORANGE e mail PWC 670 01 PWC 670 02 1...
Page 84: ...RU 165 RU 1 2 3 4 1 2 3 PWC 670 03 PWC 670 09N...
Page 87: ...21 AR AR 27...
Page 88: ...AR AR 25...
Page 89: ...AR 23 AR...
Page 90: ...AR AR...
Page 91: ...15 AR AR...
Page 92: ...5 6 7 8 PWC 670 BLACK PWC 670 ORANGE AR AR...
Page 93: ...AR AR...
Page 94: ...AR AR...
Page 95: ...AR AR 11 4 25x16 1 2 5 7 6 5 3...
Page 96: ...AR AR 9...
Page 97: ...7 AR AR...
Page 98: ...5 AR AR 1 2...
Page 99: ...3 AR AR 3 1 2 3 1 2 3...
Page 100: ...AR AR...