Troubleshooting
The hood is not
venting out properly.
Using the wrong size of ducting.
Change the ducting to at least 6” or
higher for the internal blower and 8” or
higher for the external blower.
The hood might be hanging to
high from the cook top.
Adjust the distance between the cooktop
and the bottom of the hood within 24”
and 36” range.
The wind from the opened
windows or opened doors in the
surrounding area are affecting
the ventilation of the hood.
Close all the windows and doors to
eliminate the outside wind flow.
Blockage in the duct opening or
ductwork.
Remove all the blocking from the duct
work or duct opening.
There are too many turns within
the ducting.
Limit number of turns and/or increase
duct size.
Filter is vibrating.
Filter is loose.
Adjust or change the filter.
RF Remote control
does not work.
Battery is dead.
Replace battery with type A23 12v.
Poor communication with the
hood.
Remote control must be within 15 ft of
hood.
RF Remote lost communication
with the hood.
Reset hood and remote by switching
power off at the circuit breaker for 5
minutes. Place remote on counter top
near the hood and switch the circuit
breaker back on.