Troubleshooting

TROUBLESHOOTING PROCEDURES

Issue

Cause

What to do

After installation, 

the unit doesn’t 

work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.  The switch board and control board wirings are 

disconnected.

3.  Make sure the wirings between the switch 

board and control board are connected 

properly.

4.  The wires on control board are loose.

4.  Make sure the wires on the control board are 

connected properly.

5.  The switch board or control board is defective.

5.  Change the switch board or control board.

Light works, but 

the blower is not 

turning.

1.  The blower is defective, possible seized.

1.  Change the blower.

2.  The thermally protected system detects if the 

blower is too hot to operate and shuts the blower 

down.

2.  The blower will function properly after the 

thermally protected system cool down.

3.  Damaged capacitor.

3.  Change the capacitor.

4.  The blower wire is not connected.

4.  Make sure the blower wire is plugged into the 

molex connector.

The unit is 

vibrating.

1.  The blower is not secure in place.

1.  Tighten the blower in place.

2.  Damaged blower wheel.

2.  Change the blower.

3.  The hood is not secured in place.

3.  Check the installation of the hood.

The blower is 

working, but the 

lights are not.

1.  Defective halogen bulb.

1.  Change the halogen bulb.

2.  The light bulb is loose.

2.  Tighten the light bulb.

3.  The light bulb plug is disconnected.

3.  Check the light bulb plug connection.

The hood is 

not venting out 

properly.

1.  The hood might be hanging to high from the 

cook top.

1.  Adjust the distance between the cook top and 

the bottom of the hood within 24” and 34” 

range.

2.  The wind from the opened windows or opened 

doors in the surrounding area are affecting the 

ventilation of the hood.

2.  Close all the windows and doors to eliminate 

the outside wind flow.

3.  Blockage in the duct opening or duct work.

3.  Remove all the blocking from the duct work or 

duct opening.

4.  The direction of duct opening is against the wind. 4.  Adjust the duct opening direction.
5.  Using the wrong size of ducting.

5.  Change the ducting to correct size.

Metal filter is 

vibrating.

1.  Metal filter is loose.

1.  Change the metal filter.

2.  Spring clip is broken.

2.  Change the spring clip.

The blower turns 

on by itself.

1.   The clean air function has been enabled turning 

the blower on every 4 hours.

1.   Disable the clean air function by following the 

steps on page 13.

Summary of Contents for Titan Island AK7736AS

Page 1: ...Use Care and Installation Guide Model number Serial Number www zephyronline com SEP19 0101 Zephyr Ventilation LLC Airflow Control Technology TM C Titan Island AK7736AS AK7742AS AK7748AS...

Page 2: ...www zephyronline com...

Page 3: ...pecifications 8 Mounting the Hood 9 11 PBD 1300A Dual Blower Ducting 12 FEATURES CONTROLS Electronic LCD Controls 13 Optional Remote Control 14 MAINTENANCE Cleaning Filter Removal Lights 15 TROUBLESHO...

Page 4: ...IRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND...

Page 5: ...t protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Diagram on product A cable locking connector not supplied might al...

Page 6: ...t bulbs AK7736AS AK7742AS 4 LED light bulbs AK7748AS 1 8 in round starting collar for single blower ducting 1 Paper ceiling template 1 Hardware package PARTS NOT SUPPLIED Ducting conduit and all insta...

Page 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Page 8: ...rtant to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its performan...

Page 9: ...garages All exhaust must be ducted to the outside Use rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Aluminum Tape or Duct Tape Some Ducti...

Page 10: ...6 36 41 15 16 42 47 15 16 48 17 15 16 36 42 21 5 8 48 4 3 5 16 16 1 4 27 15 16 14 5 16 31 5 8 Standard Min 33 Max 50 Z1C 0077 36 42 Z1C 0177 48 Min 49 Max 78 C L C L 7 7 8 18 36 20 15 16 42 23 15 16 4...

Page 11: ...s located behind the drywall to reinforce the mounting location FIG A1 Secure 2 M6 x 2 wood screws with washers to points A and B of the paper template FIG B Do not completely tighten screws leave app...

Page 12: ...t on the top support frame faces the front of the hood where the controls will be located FIG D The key holes on the top support frame should cover the wood screws previously installed in the ceiling...

Page 13: ...Duct Covers together by magnetic strips 9 Secure Top Duct Covers to Top Support Frame by using 4 3 16 x 1 4 screws 2 screws for each Top Duct Cover FIG H 10 Assemble Bottom Duct Covers together over T...

Page 14: ...wer to female plugs behind switch panel 1 Disconnect blower plug and white and black power cables 2 Remove 4 screws from interior of hood body attaching single blower plate to top of hood body Remove...

Page 15: ...der delay off and clean air indicator Filter Clean Reminder After 30 hours of fan usage the words Clean grease filters will show on the Display indicating it is time to clean the filters To Reset With...

Page 16: ...ing the pairing is complete RF REMOTE FUNCTIONS FIG 1 FIG 2 Blower On Speed Selection Press to power on blower and cycle through all six blower speeds Blower On Power Off By pressing the blowers will...

Page 17: ...w heat or soaked in hot soapy water Dry filters and re install before using hood Removing Baffle Filters 1 Push filter toward back of range hood using handles 2 Pivot front of filter downward 3 Remove...

Page 18: ...it is vibrating 1 The blower is not secure in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The...

Page 19: ...nd place inside the hood body below the wiring diagram or in another clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if...

Page 20: ...18 www zephyronline com Wiring Diagrams ACT 590 CFM Fan Max 175W 2 6A ACT 390 CFM Fan Max 94W 1 4A ACT 290 CFM Fan Max 63W 0 9A...

Page 21: ...onal Accessories Duct Cover Extension 36 42 Z1C 0077 Duct Cover Extension 48 Z1C 0177 Dual Internal Blower PBD 1300A Make Up Air Kit Single Blower MUA008A Make Up Air Kit Dual Blower MUA010A To order...

Page 22: ...ith this warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR...

Page 23: ...phyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures warrant...

Page 24: ...d entretien et d installation www zephyronline com Num ro de mod le Num ro de s rie Date d achat D taillant SEP19 0101 Zephyr Ventilation LLC LISEZ ET CONSERVEZ CES INSTRUCTIONS Titan Island AK7736AS...

Page 25: ...www zephyronline com...

Page 26: ...ons 8 Installation de la hotte 9 11 Conduit pour ventilateur double PBD 1200A 12 COMMANDES ET CARACT RISTIQUES Commandes effleurement 13 Commandes distance optionnelle 14 ENTRETIEN Nettoyage retrait d...

Page 27: ...ns surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R DUIRE LES RISQU...

Page 28: ...e ad quatement N introduisez aucun fusible dans le circuit neutre ou de mise la terre National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Plea...

Page 29: ...t bulbs AK7736AS AK7742AS 4 LED light bulbs AK7748AS 1 8 in round starting collar for single blower ducting 1 Paper ceiling template 1 Hardware package PARTS NOT SUPPLIED Ducting conduit and all insta...

Page 30: ...rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable la longueur totale d un conduit d a ration ne devrait pas comp...

Page 31: ...Les hottes install es trop basses pourraient tre endommag es par la chaleur en plus de pr senter des risques d incendie plus lev s tandis que les hottes install es trop hautes seront difficiles attein...

Page 32: ...maison N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban conduit en toile ou du ruban r flecteur cer...

Page 33: ...sus 35 15 16 36 41 15 16 42 47 15 16 48 17 15 16 36 42 21 5 8 48 4 3 5 16 16 1 4 27 15 16 14 5 16 31 5 8 Standard Min 33 Max 50 Z1C 0077 36 42 Z1C 0177 48 Min 49 Max 78 C L C L 7 7 8 18 36 20 15 16 42...

Page 34: ...passeront le conduit et les c bles lectriques Au besoin ajoutez les blocs de bois min 2 x 4 aux solives de plafond derri re la cloison s che pour renforcer le plafond FIG A1 Fixez deux vis bois M6 x...

Page 35: ...cadre de support sup rieur doivent couvrir les vis bois pr c demment install es au plafond Faites glisser le cadre de support vers l extr mit troite des trous pour le verrouiller en place Installez l...

Page 36: ...vez fixer la pi ce avec le pantalon pour d flecteurs au dessus du cadre de fixation sup rieur avant les pi ces de recouvrement de conduit 9 Fixez les couvre conduits sup rieurs au cadre de soutien sup...

Page 37: ...ur la convertir d un conduit vertical ventilateur simple un conduit vertical ventilateur double veuillez suivre les instructions ci dessous 5 Placez le ventilateur double l int rieur du b ti de la hot...

Page 38: ...retardement et l indicateur d air pur Rappel de nettoyage des filtres Apr s 30 heures d utilisation les mots Clean grease filters apparaissent sur le tableau d affichage indiquant qu il est temps de n...

Page 39: ...uyez sur pour mettre le ventilateur en marche et choisir l une des six vitesses de fonctionnement Ventilateur Marche Arr t Appuyez sur pour allumer le ventilateur la vitesse laquelle ilfonctionnait lo...

Page 40: ...es poign es 2 Faites pivoter l avant du filtre vers le bas 3 Enlevez le filtre en le tirant vers vous 4 R p tez les tapes pour les filtres dans le sens inverse Nettoyage du bac graisse Le bac graisse...

Page 41: ...ibre 1 Le ventilateur n est pas bien fix en place 1 Fixez bien le ventilateur en place 2 Damaged blower wheel 2 Remplacez le ventilateur 3 The hood is not secured in place 3 V rifiez l installation de...

Page 42: ...uette d aluminum appropriee indiquant le nombre de pi3 min inclus avec les documents de la hotte et placez le a l interieur du boitier de l appareil sous l etiquette du schema de cablage ou a un autre...

Page 43: ...V 60HZ 4A Consommation D nergie Total 286W Ampoule 13W Ventilateur 273W Thermiquement Prot g NOIR ROUGE JAUNE ORANGE BRUN BLANC JAUNE ORANGE BRUN ROUGE VERT BLANC NOIR BLANC NOIR BLANC NOIR Thermiquem...

Page 44: ...077 Recouvrement de conduit 48 Z1C 0177 Ventilateur interne double PBD 1300A Clapet universel d air compensation ventilaeur double MUA008A Clapet universel d air compensation ventilaeur simple MUA010A...

Page 45: ...an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE...

Page 46: ...ephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couverture de votre garantie si vous avez besoin...

Reviews: