background image

Important Safety Notice

3

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

CAUTION

To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.

OPERATION

Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair, fi ngers 
and loose clothing.

The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, 
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to 
negligence and the warranty of the unit automatically expires due to improper maintenance.

*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.

ELECTRICAL REQUIREMENTS

Important:

Observe all governing codes and ordinances.

It is the customer’s responsibility:
-  To contact a qualifi ed electrical installer.
-  To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 

latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and 
all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualifi ed electrician determine that the 
ground path is adequate.

Do not ground to a gas pipe.

Check with a qualifi ed electrician if you are not sure the range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit 
protected by a 15 or 20 ampere circuit breaker or time delay fuse.  Wiring must be 2 wire with ground.  Please also refer to 
Electrical Diagram on product.

A cable locking connector (not supplied) might also be required by local codes.  Check with local requirements, purchase 
and install appropriate connector if necessary.

Summary of Contents for Tempest II AK7536ASX

Page 1: ...e and Installation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JAN08 0201 Zephyr Corporation Tempest II AK7500ASX AK7536ASX AK7548ASX READ AND SAVE THESE INSTRU...

Page 2: ...www zephyronline com...

Page 3: ...fications 8 Electrical 9 Mounting the Range Hood 10 Single and Dual Internal Blowers 11 CBI 600B Horizontal Ducting Conversion 12 13 External Blower Preparation 14 FEATURES CONTROLS Touch Controls Fea...

Page 4: ...NS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not...

Page 5: ...To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2...

Page 6: ...ar transition for single blower horizontal ducting 2 Blower brackets for single blower horizontal ducting 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all instal...

Page 7: ...Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15...

Page 8: ...from hood duct output and as far apart between the two as possible Minimum mount height between range top to hood bottom should be no less than 26 Maximum mount height should be no higher than 36 It...

Page 9: ...st must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Du...

Page 10: ...8 24 30 30 36 42 48 12 10 24 4 18 1 3 8 9 15 16 2 3 4 2 3 16 1 1 8 8 9 16 13 3 16 2 5 16 6 7 16 2 2 1 16 CL 5 9 16 ext blwr k o elec k o 2 11 16 3 7 16 1 3 16 elec k o CL top side back 4 5 16 10 trans...

Page 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Page 12: ...ontally ducting hood refer to hood specifications on page 8 for cut out dimensions 6 Hang hood on wood board and secure using 4 M4 x 16 screws 7 Install blower s Turn to page 11 for blower installatio...

Page 13: ...ot up Secure plate to hood with 2 10x3 16 screws blower pictured is a PBI 1100A 2 Connect male end of blower wire to female plug in the hood plug is located inside the hood behind the control panel 3...

Page 14: ...blower opening on blower plate with 6 round metal cap included with the CBI 600B Secure with 3 3 5x8 screws 4 On the back of the hood remove the 6 screws holding the rectangular cap to the hood 5 Pla...

Page 15: ...Attach blower brackets to blower with 4 10x3 16 screws 2 screws for each bracket 8 Place blower into round end of 6 round transition adapter Attach brackets on blower to blower plate with 4 3 5x8 scre...

Page 16: ...er wiring and secure by turning clockwise 4 Connect 6 pin male connector from external blower wiring to 6 pin female connector on control board wire inside hood Secure green ground wire from external...

Page 17: ...s on The hood will change to speed 1 and shut down after 5 minutes Lights On Dim Off Manual On Off Switch lights On by pressing once again to dim and again to switch Off Located behind the right side...

Page 18: ...nd with grain Stainless Steel Baffle Filters The stainless steel baffle filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required...

Page 19: ...bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diamet...

Page 20: ...r is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the li...

Page 21: ...ower PBI 1100A External Blower CBE 1000 Heat Lamp Kit 30 AK0700B Heat Lamp Kit 36 AK0706B Heat Lamp Kit 48 AK0708B Back Splash 30 AK0710 Back Splash 36 AK0716 Back Splash 48 AK0718 12 Duct Cover 30 AK...

Page 22: ...se abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with...

Reviews: