Important Safety Notice

READ AND SAVE THESE INSTRUCTIONS

2

www.zephyronline.com

WARNING 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. 

WARNING 

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

a.  Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. 
b.  Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials  and vapors.  Take care when using cleaning
agents or detergents. Suitable for use in household cooking area. 

WARNING 

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE: 

a.  Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly 

on low or medium settings. 

b.  Always turn hood ON when cooking at high heat or when fl aming food   
c.  Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or fi lter. 
d.  Use proper pan size.  Always use cookware appropriate for the size of the surface element. 
e.  Keep fan, fi lters and grease laden surfaces clean. 
f.  Use high setting on hood only when necessary. 
g.  Don’t leave hood unattended when cooking. 
h.  Always use cookware and utensils appropriate for the type of and amount of food being prepared. 

WARNING 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING: 

a.  SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. 

If the fl ames do not go out  immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  

b.  NEVER PICK UP A FLAMING PAN – You may be burned.  
c.  DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d.  Use an extinguisher ONLY if:

1.  You know you have a Class ABC extinguisher, and you already know how to operate it.
2.  The fi re is small and contained in the area where it started.
3.  The fi re department is being called.
4.  You can fi ght the fi re with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.  Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards. 

Including fi re-rated construction.

b.  Suffi cient air is needed for power combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent 

back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.

c.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d.  Ducted fans must always vent to the outdoors.
e.  If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI 

(Ground Fault Interrupter protected branch circuit).

g.  NEVER place a switch where it can be reached from a tub or shower.
h.  Make sure the power is off before installing, wiring or maintenancing.

Summary of Contents for Tempest II AK7536ASX

Page 1: ...e and Installation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JAN08 0201 Zephyr Corporation Tempest II AK7500ASX AK7536ASX AK7548ASX READ AND SAVE THESE INSTRU...

Page 2: ...www zephyronline com...

Page 3: ...fications 8 Electrical 9 Mounting the Range Hood 10 Single and Dual Internal Blowers 11 CBI 600B Horizontal Ducting Conversion 12 13 External Blower Preparation 14 FEATURES CONTROLS Touch Controls Fea...

Page 4: ...NS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not...

Page 5: ...To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2...

Page 6: ...ar transition for single blower horizontal ducting 2 Blower brackets for single blower horizontal ducting 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all instal...

Page 7: ...Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15...

Page 8: ...from hood duct output and as far apart between the two as possible Minimum mount height between range top to hood bottom should be no less than 26 Maximum mount height should be no higher than 36 It...

Page 9: ...st must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Du...

Page 10: ...8 24 30 30 36 42 48 12 10 24 4 18 1 3 8 9 15 16 2 3 4 2 3 16 1 1 8 8 9 16 13 3 16 2 5 16 6 7 16 2 2 1 16 CL 5 9 16 ext blwr k o elec k o 2 11 16 3 7 16 1 3 16 elec k o CL top side back 4 5 16 10 trans...

Page 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Page 12: ...ontally ducting hood refer to hood specifications on page 8 for cut out dimensions 6 Hang hood on wood board and secure using 4 M4 x 16 screws 7 Install blower s Turn to page 11 for blower installatio...

Page 13: ...ot up Secure plate to hood with 2 10x3 16 screws blower pictured is a PBI 1100A 2 Connect male end of blower wire to female plug in the hood plug is located inside the hood behind the control panel 3...

Page 14: ...blower opening on blower plate with 6 round metal cap included with the CBI 600B Secure with 3 3 5x8 screws 4 On the back of the hood remove the 6 screws holding the rectangular cap to the hood 5 Pla...

Page 15: ...Attach blower brackets to blower with 4 10x3 16 screws 2 screws for each bracket 8 Place blower into round end of 6 round transition adapter Attach brackets on blower to blower plate with 4 3 5x8 scre...

Page 16: ...er wiring and secure by turning clockwise 4 Connect 6 pin male connector from external blower wiring to 6 pin female connector on control board wire inside hood Secure green ground wire from external...

Page 17: ...s on The hood will change to speed 1 and shut down after 5 minutes Lights On Dim Off Manual On Off Switch lights On by pressing once again to dim and again to switch Off Located behind the right side...

Page 18: ...nd with grain Stainless Steel Baffle Filters The stainless steel baffle filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required...

Page 19: ...bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diamet...

Page 20: ...r is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the li...

Page 21: ...ower PBI 1100A External Blower CBE 1000 Heat Lamp Kit 30 AK0700B Heat Lamp Kit 36 AK0706B Heat Lamp Kit 48 AK0708B Back Splash 30 AK0710 Back Splash 36 AK0716 Back Splash 48 AK0718 12 Duct Cover 30 AK...

Page 22: ...se abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with...

Reviews: