4

Import

ant 

safety 

Notice

CAUTION:

FOR GENERAL VENTILATING USE ONLY.  DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS

OR VAPORS.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A.

Use this unit only in the manner intended by the manufacturer.  If you have questions, contact the manufacturer.

B.

Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to

prevent power from being switched on accidentally.  When the service disconnecting means cannot be locked,

securely fasten a prominent warning device, such as a tag, to the service panel.

C.

Installation Work and Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All  Applicable Codes

& Standards, Including Fire-rated Construction.

D.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning

equipment to prevent back- drafting.  Follow the heating equipment manufacturers guideline and safety standards such

as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration

and Air Conditioning Engineers (ASHRAE), and the local code authorities.

E.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

F.

Ducted systems must always be vented to the outdoors.

CAUTION:

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces

within walls, ceilings, attics, crawl spaces, or garages.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

Install this hood in accordance with all requirements specified.

WARNING

To Reduce The Risk Of  Fire Or  Electric Shock, Do Not Use This Hood With Any External Solid State Speed

Control Device.

WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.

a)   Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite.

Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee,

Peppercorn Beef Flambe’).

c) Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or filter.

d) Use proper pan size.  Always use cookware appropriate for the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE

FOLLOWING

:

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric

element.  BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE

FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN - you may be burned.

c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

d) Use an extinguisher 

ONLY

 if:

1)

You know you have a class ABC extinguisher, and you already know how to operate it.

2)

The fire is small and contained in the area where it started.

3)

The fire department is being called.

4)

You can fight the fire with your back to an exit.

OPERATION

a. Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair,

fingers and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,

maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to

negligence and the warranty of the unit automatically expires due to improper maintenance.

* NOTE: Please check our website for revisions before doing any custom work.

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for Optica Island EOT-E42ASX

Page 1: ...e _____________________________________ N mero de serie Date of Purchase Date d achat _____________________________________ Fecha de compra Sales Dealer D taillant ____________________________________...

Page 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Page 3: ...not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Description o...

Page 4: ...Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Page 5: ...l local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed m...

Page 6: ...t PARTS NOT SUPPLIED Duct conduit and all tools required for installation Ductless recirculating kit to be used only in the Ductless recirculating version includes charcoal filter charcoal filter supp...

Page 7: ...online com Dimensions and clearances 42 48 14 min 31 10 16 max 49 min 30 8 16 max 43 14 16 12 3 16 27 8 16 1 26 4 16 Ductless recirculating version ONLY Note if necessary order the proper duct cover e...

Page 8: ...um Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting...

Page 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Page 10: ...ed on ceiling to position the mounting template Note location of hood front that indicated with a printed arrow side and mounting holes indicated on template Note Remember that printed arrow on templa...

Page 11: ...x 4 screws 4 1 2 3 6 7 8 FRONT 4 For non vented recirculating installations ONLY Fix the deflector on the chimney structure 5 Note disregard this step if is intended to install a remote ventilator Pu...

Page 12: ...ite and green according to the National Electrical Code and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to bl...

Page 13: ...e of top duct covers sections squere slots and fix each other with 6 screws 3 per side Rectangular slots Plan diagram top sections Nut top sections Chimney Structure 13 Install top duct covers assembl...

Page 14: ...assembly rear bottom duct covers section Plan diagram top view rear bottom duct covers section snap into place 15 Fit the front bottom duct covers section and fix both sections with 8 screws each oth...

Page 15: ...to make sure they are secure in their sockets Turn power on in service panel Check lights and blower operation per Care Use section of this manual If range hood does not operate Check that the circuit...

Page 16: ...It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cookin...

Page 17: ...d or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not affect its filtering capacity T...

Page 18: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Page 19: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Page 20: ...on Part halogen bulb 12V 20 W metal filter Part Description Part Ductless recirculating kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm ZRC 00A...

Page 21: ...21 www zephyronline com...

Page 22: ...22...

Reviews: