Ductless Recirculation

Ductless recirculation is intended for applications where an exhaust duct work is not possible to be 
installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. 
Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is 
then purified and re-circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new 
duct work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the 
exhaust option is not possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard 
Metal Filter set. Order according to its part number below. The standard mesh filters are intended to 
capture residue from cooking, and the optional charcoal filters help to purify fumes exhausted from 
cooking for recirculation.

Recirculating Kit Installation 

(required if no ducting is used)

Kit includes the charcoal filters and the air diverter plate.

Hood Model

Part Number

Filters in Package

ZNA-M90DS

ZRC-03NA

2

ZNA-E42DS

ZRC-03NA

2

1.  Purchase recirculating kit per the part number above.

2.  Secure air diverter plate to top support frame (FIG. J). Open sides of air diverter plate should face 

left and right to direct air through the louver holes located on the top duct cover.  Run 8” ducting 
from top of hood and secure to air diverter plate. 

3.  Remove baffle filters from hood. Plate the charcoal filters to the back side of the baffle filters. 

Secure the charcoal filters in place with rubber clips.

4.  Reinstall baffle filters. 

Summary of Contents for Napoli ZNA-E42DS

Page 1: ...WWW ZEPHYRONLINE COM NOV20 0101 Air ow Control Technology TM C Napoli ZNA M90DS ZNA E42DS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 2: ...2 Napoli Use Care and Installation Guide N A P O L I ISL AND CORE...

Page 3: ...ng Height Clearance Ducting 9 10 Ducting Options 11 Hood Speci cations 12 Electrical Supply 13 Cable Lock 13 Mounting the Hood 14 18 Ductless Recirculation 19 20 Features Controls 21 27 Proximity Cont...

Page 4: ...be locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive product...

Page 5: ...walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be don...

Page 6: ...onnected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Diagram o...

Page 7: ...p Duct Covers 1 Top Support Frame 2 Bottom Duct Covers 1 Bottom Support Frame 1 Hood Body 4 LumiLight LED 6W 2 Baffle Filters 1 M4 x 12 safety screw A B Front of Hood C L Cut Out Shaded Area 1 Paper c...

Page 8: ...Ft Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent feet...

Page 9: ...ing min A min B max C Standard Extension Hood Heights Duct Cover Duct Cover minimum ducted A 32 49 minimum recirculating B 36 1 2 53 1 2 maximum C 50 80 Ceiling Heights minimum ducted D 92 7 8 109 9 1...

Page 10: ...ortant to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and re hazard while hoods mounted too high will be hard to reach and will lose its performanc...

Page 11: ...metal screws and tape all joints w certi ed Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust m...

Page 12: ...T SIDE TOP of HOOD TOP SUPPORT FRAME top view 1 1 8 5 5 16 STANDARD min ducted 32 min recirc 36 1 2 max 50 Z1C 02NA min ducted 49 min recirc 53 1 2 max 80 9 13 16 25 9 16 12 13 16 35 7 16 41 15 16 13...

Page 13: ...rd or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individual pr...

Page 14: ...ure 2 6 x 1 wood screws into points A and B of the paper template FIG B Do not completely tighten screws leave approximately 1 4 exposed Hood Preparation 5 Remove screws securing top and bottom suppor...

Page 15: ...15 Napoli Use Care and Installation Guide ZEPHYRONLINE COM Installation Instructions Mounting the Hood FIG D...

Page 16: ...et metal screws FIG E1 Top support frame arms extend past lower support frame bracket with shorter hood heights FIG E2 9 Lift support frame assembly up to the ceiling making sure the word front on the...

Page 17: ...e 3 previously removed screws FIG G 13 Install electrical and duct work Seal duct work with aluminum duct tape 14 Unwrap the blue antenna wire and position it behind the duct cover from step 16 18 The...

Page 18: ...18 Napoli Use Care and Installation Guide N A P O L I ISL AND CORE Installation Instructions Mounting the Hood 1 Top Duct Covers Top Support Frame Bottom Duct Covers Bottom Support Frame FIG I...

Page 19: ...culating hood a set of charcoal lters are required on top of its standard Metal Filter set Order according to its part number below The standard mesh lters are intended to capture residue from cooking...

Page 20: ...d on the average of 1 2 hours of daily cooking time After 200 hours of use the noti cation bell icon will display When the bell is tapped the LCD display will cycle between showing REPLACE CHARCOAL FL...

Page 21: ...the fan and lights are turned off CONTROL ICONS Power Press the power icon to power on or off the fan and lights The hood has a memory function to remember the last used settings for the fan and ligh...

Page 22: ...WIFI DISCONNECTED will appear on the LCD display whenever the connection changes which will be managed via the Zephyr Connect app While the fan is on press and hold for 3 seconds to enable the delay...

Page 23: ...s the option to reset the reminder Recirculating Mode Charcoal Filter Replacement Reminder Hold and for 3 seconds to enable or disable recirculating mode which will remind you to replace the charcoal...

Page 24: ...yr Connect est disponible sur les appareils iOS utilisant iOS 11 0 ou version ult rieure ou les appareils Android utilisant la version Android 8 ou ult rieure Visitez l Apple App Store ou le Google Pl...

Page 25: ...rt Enable Hood Name Delay Off Timer Enable delay off timer for 10 minutes After 10 minutes the hood will power off Alexa Stop Disable Hood Name Delay Off Timer Disable delay off timer Control Type Goo...

Page 26: ...that may cause undesired operation Synchronization To create a unique link between your hood and remote control please follow these steps 1 With hood off press and hold on the hood until the controls...

Page 27: ...for easy storage Note The remote holder does not charge the RF remote Maximum remote control communication distance is 15 feet from the liner RF Remote Maintenance Clean the remote control using non...

Page 28: ...f the stainless steel grain To remove heavier grease build up use a liquid degreaser detergent After cleaning use a non abrasive stainless steel polish cleaners to polish and buff out the stainless lu...

Page 29: ...YRONLINE COM Maintenance 1 Pull on latch to disengage lter 2 Pull down on lter handle to remove lter Hood Model Part Number Qty to Order ZNA M90DS 50210037 2 ZNA E42DS 50210037 2 To order parts visit...

Page 30: ...o order replacement parts See the list of parts and accessories page for part numbers and contact information 1 Remove baffle lters 2 Remove each side panels by two screws and light panel by two screw...

Page 31: ...e CFM cannot be changed again CAUTION ACT Conversion Some local codes limit the maximum amount of CFM a range hood can move ACT allows you to control the maximum blower CFM of select Zephyr Ventilatio...

Page 32: ...ny wires connected to the board Disconnecting all the wires is not necessary as long as you can easily access the jumper pins shown in FIG P 2 Change plastic jumper position as shown in FIG P to the s...

Page 33: ...ide ZEPHYRONLINE COM Wiring Diagram Model ZNA E42DS Lamp LED 6W Max Fan 280W Power consumption Voltage 120VAC 60Hz Total 304W ZNA M90DS LED LED WIFI LED LED ANT MOTOR Black White Green WIRING DIGRAM B...

Page 34: ...ables are properly connected The thermally protected system detects if the blower is too hot to operate and shuts the blower down The blower will function properly after the thermally protected system...

Page 35: ...he lter Spring clip is broken on the lter Change the spring clip RF Remote control does not work Battery is dead Replace battery with type A23 12v Poor communication with the hood Remote control must...

Page 36: ...the pathway to the range hood Walls may reduce signal strength User cannot change Wi Fi connections The range hood and user s phone have already connected Enter Bluetooth settings and forget the devic...

Page 37: ...Number Replacement Parts LumiLight LED 6W Z0B0047 Baffle Filter 50210037 Optional Accessories Recirculating Kit ZRC 03NA Replacement Charcoal Filter Z0F C005 RF Remote Control 14000005 Duct Cover Ext...

Page 38: ...38 Napoli Use Care and Installation Guide N A P O L I ISL AND CORE Notes...

Page 39: ...bor costs associated with this warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO RE...

Page 40: ...a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than o...

Page 41: ...WWW ZEPHYRONLINE COM NOV20 0101 Air ow Control Technology TM C Napoli ZNA M90DS ZNA E42DS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 42: ...2 Napoli Guide d utilisation d entretien et d installation N A P O L I LE CORE...

Page 43: ...montage d gagement et gaine 9 10 Options de conduits 11 Sp ci cations de la hotte 12 Fourniture lectrique 13 Raccord de c ble 13 Montage de la hotte 14 18 Recirculation sans conduit 19 20 Fonctionnal...

Page 44: ...b Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle Lorsque le...

Page 45: ...rmes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de l q...

Page 46: ...imentation lectrique de 120 V 60 Hz et est connect un circuit de d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tr...

Page 47: ...fournies 3 Capuchons de connexion 4 rondelles 12 OD 5 4 vis bois 6 x 1 4 3 16 x 1 4 Vis de m canique 1 Trousse de quincaillerie 1 Registre circulaire de 8 pr install 2 Pi ces de recouvrement sup rieur...

Page 48: ...e utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable la...

Page 49: ...max F minimum avec conduit A 32 po 49 po minimum avec reprise d air B 36 1 2 po 53 1 2 po maximum C 50 po 80 po minimum avec conduit D 92 po 7 pi 8 po 109 po 9 pi 1 po minimum avec reprise d air E 96...

Page 50: ...important d installer la hotte la bonne hauteur de montage Les hottes mont es trop bas peuvent entra ner des dommages caus s par la chaleur et un risque d incendie tandis que les hottes mont es trop h...

Page 51: ...du ruban argent ou du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout...

Page 52: ...41 15 16 po 13 1 8 po 10 5 16 po 7 13 16 po 7 8 po Entr e CA C L C L 4 13 16 po 9 16 po DEVANT 10 1 16 po 10 1 14 po C L 4 3 14 po 6 3 4 po 6 1 2 po DEVANT C T DESSUS de la HOTTE CADRE DE FIXATION SU...

Page 53: ...vation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 ls avec terre Veuillez galement vous r f rer au sch ma lectrique...

Page 54: ...Fixez 2 vis bois de 6 x 1 po aux points A et B du gabarit en papier FIG B Ne serrez pas compl tement les vis laissez environ 1 4 po expos Pr paration de la hotte 5 Retirez les vis xant ensemble les ca...

Page 55: ...15 Napoli Guide d utilisation d entretien et d installation ZEPHYRONLINE COM Instructions d installation Montage de la hotte FIG D...

Page 56: ...ide de 8 vis t le M4 x 8 FIG E1 Les bras du cadre de support sup rieur d passent le support du cadre de support inf rieur avec des hauteurs de capot plus courtes FIG E2 9 Soulevez l ensemble du cadre...

Page 57: ...rps de la hotte l aide des 3 vis retir es pr c demment FIG G 13 Installer les travaux lectriques et les conduits Sceller les conduits avec du ruban adh sif en aluminium 14 D roulez le l d antenne bleu...

Page 58: ...its sup rieurs Cadre de support sup rieur Couvercles de conduit inf rieurs Cadre de support inf rieur FIG I 18 Assemblez les couvercles de conduit inf rieurs ensemble sur les couvercles de conduit sup...

Page 59: ...standard Commandez selon son num ro de pi ce ci dessous Les ltres mailles standard sont destin s capturer les r sidus de cuisson et les ltres charbon en option aident puri er les fum es puis es de la...

Page 60: ...uisson par jour Apr s 200 heures d utilisation l ic ne de la cloche de noti cation s affiche Lorsque vous appuyez sur la cloche l cran LCD alterne entre l affichage de REPLACE CHARCOAL FLTR et HOLD UP...

Page 61: ...nes ne dispara tront pas tant que le ventilateur et les lumi res ne seront pas teints IC NES DE CONTR LE Allumer Appuyez sur l ic ne d alimentation pour allumer ou teindre le ventilateur et les lumi...

Page 62: ...NNECTED appara tront sur l cran LCD chaque fois que la connexion change ce qui sera g r via l application Zephyr Connect Retard automatique d sactiv Pendant que le ventilateur est en marche maintenez...

Page 63: ...n Zephyr Connect offre la possibilit de r initialiser le rappel Maintenez et pendant 3 secondes pour activer ou d sactiver le mode de recirculation qui vous rappellera de remplacer le ltre charbon L c...

Page 64: ...ication Zephyr Connect est disponible sur les appareils iOS utilisant iOS 11 0 ou version ult rieure ou les appareils Android utilisant la version Android 8 ou ult rieure Visitez l Apple App Store ou...

Page 65: ...rt Enable Hood Name Delay Off Timer Activer la minuterie d arr t pendant 10 minutes Apr s 10 minutes la hotte s teint Alexa Stop Disable Hood Name Delay Off Timer D sactiver le temporisateur d arr t T...

Page 66: ...er un lien unique entre votre hotte et la t l commande veuillez suivre ces tapes 1 Avec le capot teint appuyez et maintenez sur le capot jusqu ce que les commandes affichent REMOTE PAIRING 2 Appuyez...

Page 67: ...marque le support de t l commande ne charge pas la t l commande RF La distance de communication maximale de la t l commande est de 15 pieds de la doublure Maintenance distance RF Nettoyez la t l comma...

Page 68: ...e Pour liminer les accumulations de graisse plus lourdes utilisez un d tergent d graissant liquide Apr s le nettoyage utilisez un produit de polissage nettoyant pour acier inoxydable non abrasif pour...

Page 69: ...OM Entretien 1 Tirez sur le loquet pour d sengager le ltre 2 Tirez sur la poign e du ltre pour retirer le ltre Mod le de hotte Num ro de pi ce Quantit ZNA M90DS 50210037 2 ZNA E42DS 50210037 2 Pour co...

Page 70: ...echange Voir la page de la liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es 1 Retirez les ltres d ecteurs 2 Retirez chaque panneau lat ral par deux vis et le panneau lumin...

Page 71: ...hang AVERTISSEMENT Conversion ACT Certains codes locaux limitent la quantit maximale de CFM qu une hotte de cuisini re peut d placer ACT vous permet de contr ler le CFM maximum du ventilateur de certa...

Page 72: ...imprim Lorsque la hotte est mise en marche pour la premi re fois le nouveau CFM maximum du ventilateur appara t sur l cran LCD pendant deux secondes Le maximum de CFM du ventilateur peut galement tre...

Page 73: ...on ZEPHYRONLINE COM Sch ma de c blage Mod le ZNA E42DS Lampe LED 6W Max Ventilateur 280W Consommation d nergie Voltage 120VAC 60Hz Total 304W ZNA M90DS LED LED WIFI LED LED ANT MOTEUR Noir Blanc Vert...

Page 74: ...ue tous les c bles sont correctement connect s Le syst me thermiquement prot g d tecte si le ventilateur est trop chaud pour fonctionner et arr te le ventilateur Le ventilateur fonctionnera correcteme...

Page 75: ...Changer le clip ressort La t l commande RF ne fonctionne pas La batterie est morte Remplacez la batterie par un type A23 12v Mauvaise communication avec la hotte La t l commande doit tre moins de 15...

Page 76: ...re la puissance du signal L utilisateur ne peut pas modi er les connexions Wi Fi La hotte et le t l phone de l utilisateur sont d j connect s Entrez les param tres Bluetooth et oubliez l appareil pour...

Page 77: ...rticle Pi ces de rechange LumiLight LED 6W Z0B0047 Filtre chicane 50210037 Accessoires optionnels Kit de recirculation ZRC 03NA Filtre charbon de rechange Z0F C005 T l commande RF 14000005 Extension d...

Page 78: ...38 Napoli Guide d utilisation d entretien et d installation N A P O L I LE CORE Remarques...

Page 79: ...e d placement du technicien votre domicile pour que le Produit soit r par enlev ou r install Un an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de main d...