![Zephyr MESA DME-M90ASSX Installation Instructions Manual Download Page 15](http://html1.mh-extra.com/html/zephyr/mesa-dme-m90assx/mesa-dme-m90assx_installation-instructions-manual_4019781015.webp)
5. Install the flange and fix it to the blower
plate with the (4) screws. Fig. 5
6. Put the top cover back on.
7. With the aid of a slotted screwdriver, bre-
ak the grommet of circular hole through
which the wires pass. Fig. 6
8. Insert the female connector in the ter-
minal box already attached to the hood.
Fig. 7A
Pass the wires of the remote motor throu-
gh the terminal box hole and connect
them to the connector wires. Fig.7B
Note
: Carry out the power supplly con-
nection in accordance with the national
electric code, ANSI/NFPA 70-1999.
Note1
: A cable lock (not included) may be
required by local codes. Please review
local codes for more information.
- 15 -