background image

 5. Secure capacitor box connected to  the 

provided cable to the blower  plate using 
(2) screws included with the blower. See 
Fig.5

6. Secure Green/Yellow ground wire con-

nected to the cable to the provided ca-
pacitor  to blower plate. Fig.6

7. Attach the 6 pin male molex connector 

from blower wire to the 6 pin female mo-
lex connector located inside the blower 
housing. See Fig.7

8. Install the blower and plate on the inside 

of the blower housing: carry out the in-
structions at step 2 in reverse order then 
use the screws provided to complete in-
stallation. (Tot. 12). Fig.8

9. Connect 9 pin male molex connector 

from blower wire to 9 pin female molex 
connector on the capacitor wire. See 
Fig.9

- 12 - 

Summary of Contents for MESA DME-M90ASSX

Page 1: ...www zephyronline com MESA DME M90ASSX DME M90AMBX DME M90ASGX RANGE HOOD Installation instructions ENGLISH 3 FRAN AIS 27...

Page 2: ......

Page 3: ...ag 10 INSTALLATION INTERNAL BLOWER pag 11 EXTERNAL IN LINE BLOWER PREPARATION pag 14 DUCTING OPTIONS pag 17 MOUNTING THE RANGE HOOD pag 18 POWER SUPPLY CONNECTION pag 19 TOUCH CONTROL pag 20 OPTIONAL...

Page 4: ...lating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced im pellers keep drywall spray construction dust etc...

Page 5: ...se fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING P...

Page 6: ...nprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F Before performing any mainteinance operation disconn...

Page 7: ...asonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the...

Page 8: ...op Cover Hybrid Baffle Filters Led Light List of Materials Control Remote Blower Wiring Harness Remote Blower Wiring Extension Remote Blower Box Blower Bracket Electrical System Box Remote Blower Coll...

Page 9: ...roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 150 equivalent feet 6 roundto 3 1 4 x 1...

Page 10: ...14 1 16 10 9 16 35 5 16 19 11 16 10 13 16 11 16 11 5 16 21 3 4 29 5 8 2 7 16 8 11 16 2 5 8 front of hood side of hood top of hood Hood Specifications back of hood 10...

Page 11: ...stalling the internal blower CAUTION To reduce the risk of fire and electric shock install this rangehood only with internal blower models CBI 290A or CBI 600A For external and in line blower preparat...

Page 12: ...the 6 pin male molex connector from blower wire to the 6 pin female mo lex connector located inside the blower housing See Fig 7 8 Install the blower and plate on the inside of the blower housing car...

Page 13: ...WARNING Place electrical wiring inside the blower housing 10 Put the top cover back on The hood is now ready to be installed on the wall 13...

Page 14: ...TION To reduce the risk of fire and electric shock install this rangehood only with remote blowers rated maximum 6 2 A For internal blower instructions please turn to page 11 Installation External In...

Page 15: ...nsert the female connector in the ter minal box already attached to the hood Fig 7A Pass the wires of the remote motor throu gh the terminal box hole and connect them to the connector wires Fig 7B Not...

Page 16: ...nectors to 6 pin female molex connectors inside blo wer housing See Fig 8 Note2 Check local codes to determine minimum wire gauge See manual included with external and in line blower for instructions...

Page 17: ...iling attics or garages All exhaust must be ducted to the outside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tap...

Page 18: ...ded with your hood on the wall to determine where to add the screws for mounting the hood Make sure the bottom of the template aligns with the bottom of where the hood will be located See Fig 9 2 Lift...

Page 19: ...2 Connect the wires of the hood to those of the power supply as described Fig 2 BLACK L line WHITE N neutral GREEN YELLOW G ground A double pole switch properly rated must be installed to provide the...

Page 20: ...FILTER REPLACE REMINDER disabled by default must be enabled by user if recirculating hood To enable Charcoal Filter Replacement Function hold buttons D and F simultaneously for four seconds The A butt...

Page 21: ...device must accept any interference received including interference that may cause undesired operation GENERAL INFORMATION Remove any protective film from the remote surface prior to using it The remo...

Page 22: ...d it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls Clean the range hood by carrying out the following...

Page 23: ...Wiring Diagram INTERNAL BLOWER CIRCUIT DIAGRAM 23...

Page 24: ...Wiring Diagram REMOTE BLOWER CIRCUIT DIAGRAM 24...

Page 25: ...old DME MERAIL 00SG Remote Control DME 14000010 Internal Blower 290 CFM DME CBI 290A Internal Blower 600 CFM DME CBI 600A External Blower 1000 CFM DME CBE 1000 In Line Blower 1000 CFM DME PBN 1000A To...

Page 26: ...ducts After the first year from the date of your original purchase you are also responsible for all labor costs associated with this warranty All Products must be installed by a qualified professional...

Page 27: ......

Page 28: ...www zephyronline com MESA DME M90ASSX DME M90AMBX DME M90ASGX ENGLISH 3 FRAN AIS 27 HOTTE PER CUISINE Notice d utilisation...

Page 29: ...ON MOTEUR INTERIEUR pag 38 PREPARATION MOTEUR EXTERIEUR ET IN LINE pag 41 OPTIONS D ASPIRATION pag 44 FIXATION DE LA HOTTE pag 45 RACCORDEMENT AU RESEAU ELECTRIQUE pag 46 CONTR LE TACTILEE pag 47 T L...

Page 30: ...l air s assurer que celui ci est bien transport l ext rieur travers un conduit d vacuation Ne pas vacuer l air dans des interstices tels qu entre des cloisons ou des plafonds dans des greniers des esp...

Page 31: ...r les graisses restent propres F N utiliser une flamme lev e que lorsque cela est n cessaire R chauffer l huile lentement faible ou moyenne temp rature G Ne jamais laisser la cuisini re sans surveilla...

Page 32: ...Air American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et par les autorit s locales pr pos es C Au cours des op rations de d coupage ou de perforation du mur ou du plafon...

Page 33: ...tre 2 fils avec mise la terre Veuillez galement vous r f rer au sch ma lectrique du produit Un connecteur de verrouillage de c ble non fourni peut galement tre requis par les codes locaux V rifiez les...

Page 34: ...e prise sur un circuit diff rent de celui sur lequel le r cepteur est connect Consultez le revendeur ou un technicien radio TV exp riment pour obtenir de l aide AVERTISSEMENT Prop 65 Avertissement pou...

Page 35: ...peau Filtres chicane hybrides Lampes Commandes Harnais C blage Ventilateur exterieur Exstension C blage Ventilateur exterieur Bo te du ventilateur exterieur Support du ventilateur Ensemble tableau ele...

Page 36: ...x Nombre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air conven...

Page 37: ...9 16 35 5 16 19 11 16 10 13 16 11 16 11 5 16 21 3 4 29 5 8 2 7 16 8 11 16 2 5 8 Partie avant de la hotte Partie sup rieure de la hotte Partie lat rale de la hotte Specifications Techniques Arri re de...

Page 38: ...ructions qui suivent concernent l installation du moteur int rieur AVERTISSEMENT fin de reduire le risque de incendie et de shock l ctri que il faut installer la hotte seulement avec le moteur a l int...

Page 39: ...du moteur Fig 6 7 Raccordez le connecteur m le 6 voies du moteur au connecteur femelle 6 voies reli l int rieur du corps moteur Fig 7 8 Installer le moteur et la plaque l int rieur du corps moteur en...

Page 40: ...AVERTISSEMENT Placez les c bles lectri ques l int rieur du corps moteur 10 R introduire le chapeau A ce point la hotte est pr te pour tre install e au mur 40...

Page 41: ...AVERTISSEMENT fin de reduire le risque de incendie et de shock l ctri que il faut installer la hotte seulement avec le moteur a l ext rieur regle au maximum 6 2A Pour les instructions du moteur int r...

Page 42: ...ecteur femelle dans la bo te des connexions d j fix e la hot te Fig 7A Faire passer les fils du moteur au travers du couvercle de la bo te des connexions et les relier ceux se trouvant l int rieur de...

Page 43: ...urs m les 6 voies aux deux connecteurs femelles 6 voies se trouvant l int rieur du corps moteur Fig 8 Remarque2 Consultez les r glementa tions locales pour d terminer le diam tre minimum prescrit du c...

Page 44: ...e vacu l ext rieur sauf si on opte pour l option de la recirculation Utilisez exclusivement des conduits en m tal rigide simple paroi Proc dez toutes les connexions en vous servant des vis auto taraud...

Page 45: ...nt des vis pour le montage de la hotte Assurez vous que la ligne au fond du gabarit est align e avec la partie inf rieure de la hotte l endroit o celle ci devra tre positionn e Fig 9 2 Soulevez la hot...

Page 46: ...vissant les 2 vis Fig 1 2 Reliez les fils du hotte ceux de l ali mentation lectrique en proc dant aux raccordements suivants Fig 2 NOIR L ligne BLANC N neutre VERT JAUNE G terre Un interrupteur bipola...

Page 47: ...ter et le minuteur de 60 heures est r initialis RAPPEL DE REMPLACEMENT DU FILTRE A CHARBON d sactiv par d faut doit tre activ par l utilisateur s il s agit d une hotte recirculation Pour activer la fo...

Page 48: ...ris les interf rences qui peuvent provoquer un fonctionnement ind sirable INFORMATIONS DE CARACTERE GENERAL Retirer la pellicule protectrice de la surface distance avant de l utiliser La t l commande...

Page 49: ...sque d incendie il est conseill de nettoyer le filtre au maxi mum tous les deux mois en respectant les instructions suivantes Retirer les filtres de la hotte et les mettre tremper dans une solution co...

Page 50: ...Sch ma de c blage SCH MA DU CIRCUIT DE MOTEUR INTERIEUR 50...

Page 51: ...Sch ma de c blage SCH MA DU CIRCUIT DE MOTEUR EXTERIEUR 51...

Page 52: ...mmande DME 14000010 Moteur Interieur 290 CFM DME CBI 290A Moteur Interieur 600 CFM DME CBI 600A Moteur Exterieur 1000 CFM DME CBE 1000 Moteur In Line 1000 CFM DME PBN 1000A Pour commander les pi ces d...

Page 53: ...ous garantie ou vous pourriez avoir d bourser les frais de d placement du technicien votre domicile pour que le Produit soit r par enlev ou r install Un an apr s la date d achat originale du Produit v...

Page 54: ......

Page 55: ......

Page 56: ...new range hood at www zephyronline com registration IT S IMPORTANT Prompt registration helps in more ways than one Ensures warranty coverage should you need service Ownership verification for insuran...

Reviews: