Blower Installation
Internal Blowers (CBI-290C, CBI-600A, or PBI-1100B)
1. Choose blower ducting outlet. Duct options are from top, side, or front. Refer to page 10 for more
details.
2. Remove knockout plate for only one chosen duct outlet position.
3. Attach internal blower plate to blower by (4) M4 x 16 screws provided with internal blower, FIG. I.
4. Install internal blower with blower plate into hood body. Bottom of blower plate hooks into body
tabs. Top of blower plate attaches by (2) 3/16 x 1/2” screws, FIG. J.
Blower Plate Rests on Hook
FIG. I
FIG. J
External and In-Line Blowers (CBE-1000 or PBN-1000A)
1. Choose blower ducting outlet. Duct options are from
top, side, or front. Refer to page 10 for more details.
2. Remove knockout plate for only one chosen duct outlet
position.
3. Attach 10” round duct collar to desired outlet position,
FIG. K.