background image

10

Inst

allation  - Ductwork Calculation Sheet

3 1/4 ” x 10”
Rect.,
straight

6 ” Round,,
straight

7",  8”
Round,,
straight

3 1/4 ” x 10”
Rect.90°
elbow

3 1/4 ” x 10”
Rect.45°
elbow

3 1/4 ” x 10”
Rect.90°
flat elbow

3 1/4 ” x 10”
Rect.
wall cap
with damper

3 1/4 ” x 10”
Rect.to
6 ” round
transition

3 1/4 ” x 10”
Rect.to
6 ” round
transition
90° elbow

6 ” Round,,
90° elbow

6 ” Round,,
45°elbow

1 Ft.

x (

) =

1 Ft.

x (

) =

1 Ft.

x (

) =

15 Ft.

x (

) =

9 Ft.

x (

) =

24 Ft.

x (

) =

30 Ft.

x (

) =

5 Ft.

x (

) =

15 Ft.

x (

) =

15 Ft.

x (

) =

9 Ft.

x (

) =

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

6" Round
wall cap
with damper

6” Round,
roof cap

6” Round to
3 1/4 ” x 10”
rect.
transition

6” Round to
3 1/4 ” x 10”
rect.
transition
90° elbow

7", 8" round
90° elbow

7", 8" round
45° elbow

7", 8" Round
wall cap
with damper

7", 8"
Round,
roof cap

7” Round to
3 1/4 ” x 10”
rect.
transition

6” Round to
3 1/4 ” x 10”
rect.
transition
90° elbow

30 Ft.

x (

) =

30 Ft.

x (

) =

1 Ft.

x (

) =

16 Ft.

x (

) =

15 Ft.

x (

) =

9 Ft.

x (

) =

30 Ft.

x (

) =

30 Ft.

x (

) =

8 Ft.

x (

) =

15 Ft.

x (

) =

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Ft.

Duct pieces

Equivalent number
lenght x used

=

Total

Duct pieces

Equivalent number
lenght x used

=

Total

Subtotal column 2 =

Subtotal column 2 =

Total ductwork

=

Subtotal column 1 =

Maximum Duct Length:

 For satisfactory air movement, the

total duct length should not exceed 100 equivalent feet.

Note:

 Do not use smaller size duct than specified.

Summary of Contents for CPA-E42ASX

Page 1: ...e Date d achat _____________________________________ Fecha de compra Sales Dealer Détaillant _____________________________________ Distribuidor LI2ZRA DEC06 0101 READ AND SAVE THESE INSTRUCTIONS Guide d utilisation d entretien et d installation Guía de instalación uso y mantenimiento LISEZ CES INSTRUCTIONS ET CONSERVEZ LES LEAY GUARDE ESTAS INSTRUCCIONES Padova CPA E42ASX CPA E48ASX CPA E54ASX www...

Page 2: ...se Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this appliance Requirement 120 V AC 60 Hz 15 or 20 A Branch Circuit APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS English page 2 French page 28 Spanish page 56...

Page 3: ... methods 9 Preparation 9 Installation Ductwork Calculation Sheet 10 Installation Preliminary Operations 11 Installation Internal Blower 12 13 Top discharge Vertical discharge 12 Rear discharge Horizontal discharge 12 Internal blower installation 13 Installation External Blower Preparation 14 15 Vertical discharge 14 Horizontal discharge 14 External blower electrical connection Preliminary operatio...

Page 4: ...cal connection 20 Description of the Hood 21 Features Controls Touch Controls Features 22 Description of control panel 22 Features Controls Baffle Filters Change Indicator 23 Maintenance 24 25 Cleaning 24 Baffle Filter 24 Replacing the halogen light bulb 24 Replacing the mood lighting bulb 25 Trouble Shooting 26 List of Parts and Accessories 27 Table of Contents ...

Page 5: ...ck Do Not Use This Hood With Any External Solid State Speed Control Device WARNING TOREDUCETHERISKOFARANGETOPGREASEFIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing food I e Crepes Suzette Cherries Jubilee Peppercorn B...

Page 6: ... S A listed conduit connector must be provided at each end of the power supply conduit At the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 BEFORE INSTALLING THE HOOD 1 For the most efficient air flow e...

Page 7: ...ound transition 1 piece Rectangular transition air discharge flange External blower wiring box with wires Template 1 piece Use Care and Installation Guide Warranty PARTS NOT SUPPLIED Duct conduit and all tools required for installation Internal blower To be used only in case of Internal blower installation External blower To be used only in case of External blower installation Front panel CAUTION ...

Page 8: ...section for the passage of the discharge pipe for connection to the external motor Consult the template for the passage of pipes under this measurement Hood with external motor Above this measurement a hole may be made on the rear panel for the outward passage of the discharge pipe Consult the template for the passage of pipes under this measurement ...

Page 9: ...r Internal blower installation only PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting material is provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling Before making cutouts make...

Page 10: ... cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Round roof cap 7 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 30 Ft x 30 Ft x 1 Ft x 16 Ft x 15 Ft x 9 Ft x 30 Ft x 30 Ft x 8 Ft x 15 Ft x Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Duct pieces Equivalent number ...

Page 11: ...ews We recommend to record and keep all of these components in a safe place ready to be used as required Remove stainless mesh filters See relative paragraph on Maintenance section of this manual Release the 4 per side threaded knobs and remove the internal left right side covers Unscrew the 4 screws that fix the cover to the Junction box to access mains connection area ...

Page 12: ...ing the 4 fixing screws From the inside of the hood rear side remove cover rectangular transition support from the range hood body unscrewing the 4 fixing screws Install the motor support to the body of the hood Rear side with 4 screws in place of the rear cover previously removed Note Lip of motor support must be towards the inside of the hood in order for screw holes to line up Close from the in...

Page 13: ... blower to the support with 4 screws Provided check that the rectangular outlet of the blower matches with the rectangular slot of the support Note The 4 fixing screws must be screwed in from the outside of the hood See photo below Connect the blower to the range hood Installation Internal Blower ...

Page 14: ...xternal Blower Preparation Note for internal blower installation disregard the instruction on this next page and consult the instruction on the previous pages See pages 12 13 Note 2 Refer to the CBE 1000 manual for instructions on mounting the external blower to a roof or exterior wall The manual is available on our website and is included in the external blower packaging WARNING Do not use the re...

Page 15: ...wer junction box See diagram below Installation External Blower Preparation EXT BLOWER REMOTE FAN UNIT JUNCTION BOX BLACK HIGH RED LOW WHITE COMMON BLUE MED Y G GROUND HOOD CONNECTION WIRE TO WIRE BLACK RED WHITE BLUE Y G CONDUIT WIRES RED LOW Y G GROUND BLACK HIGH BLUE MED WHITE COMMON Connect the eyelet terminal of the yellow green conductor to the grounding screw located inside the hood Remove ...

Page 16: ...studs through the front bodies corresponding holes Use 8 wing nuts to attach and secure See diagrams below 2 3 1 4 6 5 8 7 1 2 3 4 5 6 7 8 3 4 Installation Front Panel NOTE The front panel is not supplied with the range hood and must be purchased separately x 8 ...

Page 17: ... as follows Cutout drywall along marked lines Install wood blocking between studs and make sure it is flush with existing stud front Make sure all mounting screws will anchor to added studs Replace drywall and refinish 9 Determine and make all necessary cuts in the wall for the vent system Install the vent system before the canopy hood See Venting methods and Dimensions and clearance paragraphs IM...

Page 18: ...rence Position reference CenterLine Duct cover support barcket Installation Installing the Duct Covers Unscrew the 4 screws that fix the section of the Duct Cover Starting collar and release all parts Install the upper section to the support bracket with 2 screws Note Check that joined seam is positioned towards the back Note2 The lower section Collar of the duct cover assembly must be installed a...

Page 19: ...n lower bracket WARNING Excessive Weight Hazard Use three or more people to move and install range hood Failure to do so can result in back or other injury 16 Secure hood with screws and washers 17 Connect the ducting to the transition Seal with duct tape Note If Duct has been already fixed to transition See installation step 15b install the transition to the hood with 4 screws Do not use duct sma...

Page 20: ...e and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to black or red in junction box white to white and green to green yellow Close and secure junction box cover 19 Note disregard this step if the hood has been fitted with an internal blower Purchase and install an External blower See paragraph Before installin...

Page 21: ...21 www zephyronline com Description of the Hood 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover 6 2 2 3 3 4 1 5 ...

Page 22: ...ease speed level The display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated Press once a dot flashes in the lower right hand side of display indicating the function is on The hood will completely shut down in 15 minutes 4 Lights On Off Dim Switch lights On and Off by pressing once To dim lights press and ho...

Page 23: ...can be cleaned by hand with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting Function Reset the Filter Clean Reminder timer when filters are cleaned and re installed with hood off Press and hold for approx 5 seconds the display will appear hold for approx...

Page 24: ...al retaining clip together the light socket will now protude from the hood allowing you to remove the bulb Be careful when releasing retain clip as it is under pressure to hold it in place Replacement halogen bulbs are available at most stores which sell light bulbs Purchase type GU 10 120V 50W Follow package directions Reinstall the metal retaining ATTENTION Prior to any maintenance operation ens...

Page 25: ...GHTING BULB To replace mood lighting bulb remove baffle filter from hood To access lamp area remove the two threaded knobs that fix the cover Unscrew mood lighting bulb counter clockwise and replace with a standard max 40W type T10 125V 130V medium base bulb ...

Page 26: ...ng area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loose Issue Cause What to do 1 Make sure the circuit breaker and the unit s power is ON 2 Check the power connection with the unit is connected properly 3 Make sure the wirings between the switch board a...

Page 27: ...s CPC 0112 Front Panel 48 SS CPC 0018 Front Panel 48 Brass CPC 0118 Front Panel 54 SS CPC 0015 Front Panel 54 Brass CPC 0115 50210002 Doluflex 6pc Blank 42 CDO 0042 Doluflex 6pc Blank 48 CDO 0048 Doluflex 6pc Blank 54 CDO 0054 Veneer 6pc Copper 42 CDO 0142 Veneer 6pc Copper 48 CDO 0148 Veneer 6pc Copper 54 CDO 0154 Veneer 6pc Stainless 42 CDO 0242 Veneer 6pc Stainless 48 CDO 0248 Veneer 6pc Stainl...

Reviews: