background image

www.zephyronline.com

 IMPORTANT SAFETY INSTRUCTIONS

 

FOR RESIDENTIAL USE ONLY

 

READ AND SAVE THESE INSTRUCTIONS

 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

 

IMPORTANT

: Save these Instructions for the Local Electrical Inspectors use.

 

INSTALLER

: Please leave these Instructions with this unit for the owner.

 OWNER

: Please retain these instructions for future reference.

 Take care when using cleaning agents or detergents.
 Suitable for use in household cooking area

 WARNING

 - To reduce the risk of fi re or electric shock, do not use this fan 

with any Solid-State Speed Control Device.

 CAUTION

 - To reduce risk of fi re and to properly exhaust air, be sure to duct 

air outside – Do not vent exhaust air into spaces within walls or ceilings or into 
attics, crawl spaces, or garages.

 CAUTION

 - For general ventilating use only. Do not use to exhaust hazardous 

or explosive materials and vapors.

 

CAUTION

 - To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off  power unit.

 CAUTION

 - Please read specifi cation label on product for further information 

and requirements.

 WARNING

 – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

A. 

Use this unit only in the manner intended by the manufacturer. If you have 

ques        tions, contact the manufacturer.

B.

 Before servicing or cleaning unit, switch power off  at service panel and lock   

the service disconnecting means to prevent power from being switched on ac-
cidentally. When the service disconnecting means cannot be locked, securely    
fasten a prominent warning device, such as a tag, to the service panel.

 WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.

 Never leave surface units unattended at high settings. Boilovers cause smo-

king and greasy spillovers that may ignite. Heat oils slowly on low or medium 

S

a

fe

ty instruc

tions

- 4 - 

Summary of Contents for ASL-E42ASX

Page 1: ...www zephyronline com Surface Is ASL E42ASX ASL E48ASX RANGE HOOD Installation instructions...

Page 2: ...www zephyronline com HOTTE PER CUISINE Notice d utilisation Pag 23 CAMPANA EXTRACTORA Manual de utilizaci n Pag 45 CAPPA ASPIRANTE istruzioni per l uso Pag 67 2...

Page 3: ...LCULATION SHEETS pag 8 HOOD SPECIFICATION pag 9 INSTALLATION INTERNAL BLOWER pag 10 EXTERNAL IN LINE BLOWER PREPARATION pag 12 DUCTING OPTIONS pag 14 MOUNTING THE RANGE HOOD pag 15 POWER SUPPLY CONNEC...

Page 4: ...to exhaust hazardous or explosive materials and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Plea...

Page 5: ...AREFUL TO PREVENT BURNS If the flames do not go out mmediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towe...

Page 6: ...This unit must be grounded WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS A Do not check filters with hood working...

Page 7: ...ls Decorative Mesh Filters Control Blower Housing Light Bulbs Range Hood Body Duct Covers Support Frame Assembly TYPE DESCRIPTION N A M4 1 1 B 1 8 x 1 4 28 C 1 4 x 2 3 4 4 D M4 x 9 16 4 Duct Cover Cei...

Page 8: ...www zephyronline com Ducting Calculation Sheet Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 8...

Page 9: ...Hood Specifi cations front of hood side of hood top of hood 9...

Page 10: ...port bracket to the motor housing and then remove the bracket See Fig 1 2 Insert the 6 sheet metal flange in the motor air exhaust outlet Fig 2A Then insert the plate supplied with the motor and secur...

Page 11: ...e motor and bracket inside the motor housing completing the installation using the other screws 6 type B that have been sup plied Tot 13 type B Fig 7 8 Connect 9 pin male molex connector from blower w...

Page 12: ...cut circle in the lid located on the remote motor sup port bracket using a flat head screwdriver Fig 1 2 Remove the cover by un doing the 3 screws Fig 2 3 Secure 8 round blower col lar to top of blow...

Page 13: ...6 Reinstall the cover on the motor housing by following the instructions from step 2 in re verse order 7 Attach 6 pin male molex connectors to 6 pin female molex connectors inside blower hou sing See...

Page 14: ...spaces ceiling attics or garages All exhaust must be ducted to the outside unless using the recirculating op tion Use single wall rigid Metal ductwork only Fasten all connections with sheet metal scr...

Page 15: ...e decorative mesh filters so that the range hood is easier to handle MOUNTING TO THE CEILING The following instructions assume the installer has access to the attic or crawl space Each installation ma...

Page 16: ...4 holes in the ceiling and drive in 3 type C screws without completely tightening them Pay attention not to in sert the screw into the hole marked with an X on the hole template Fig 11 4 Lift the hood...

Page 17: ...Fig 13 6 Insert the motor housing into the support frame assembly and secure it using 8 type B screws Fig 14 7 Connect the equipment to the power supply by following the steps shown in the section POW...

Page 18: ...n closure using a flat head screwdriver Fig 15 9 Remove the power supply cover by un doing the 2 screws Fig 16 10 Connect the supply conduit to the cover then connect the hood to the power sup ply by...

Page 19: ...e ducting for your installation not supplied to the collar on top of the housing Fig 18 14 Extend upper duct cover to the ceiling and secure it to the duct cover ceiling bra cket using the 4 screws pr...

Page 20: ...vent a fire hazard it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls Clean the range hood by carrying...

Page 21: ...Light Bulb GU4 20W each ASL Z0B0030 OPTIONAL ACCESSORIES Recirculating Kit ASL ZRC 00SL Replacement Charcoal Filters ASL Z0F 00AC Duct Cover Extension 12 ceiling ASL Z1C 00SL To order parts visit us...

Page 22: ...www zephyronline com 22...