- 27 -
WIRING
(EXTERNAL AND IN-LINE BLOWER)
1. Run 4-wire plus ground power cable from the remote blower to the remote blower wiring
box marked “motor connection” (Fig.34).
2. Feed 6” of cable through the knockout opening and secure the cable to the wiring box
with an appropriate connector.
3. Make electrical connections at the hood (box marked 120 Vac input). Connect white-to-
white, black-to-black, green-to-ground (Fig.34).
4. Make electrical connections (remote blower box marked “motor connection”). Connect
white-to-white, black-to-black, blue-to-blue, red-to-red, green-to-ground.
5. Fix the wiring box covers and screws. Make sure wires are not pinched between the cover
and box.
External blower connection:
1. Make electrical connections at the remote blower (see instructions provided with the
remote blower).
FIG.34
REMOTE BLOWER
HOOD WIRE HAR-
NESS
BOX MARKED
“120 VAC
INPUT”
REMOTE BLOWER BOX
CONNECT:
WHITE-TO-WHITE,
BLACK,-TO-BLACK,
GREEN-TO-GROUND.
(2) MOUNTING
SCREWS (3.9 x 6
mm Flat Head)
WHITE
(COMMON)
BLACK
(HIGH)
BLUE
(MED)
RED
(LOW)
GREEN
(GROUND)
CONNECT:
WHITE-TO-WHITE,
BLACK-TO-BLACK,
BLUE-TO-BLUE
RED-TO-RED
GREEN-TO-GROUND.
Summary of Contents for ALU-E63
Page 2: ...2...
Page 8: ...8 HOOD SPECIFICATIONS ALU E43...
Page 9: ...9 HOOD SPECIFICATIONS ALU E63...
Page 10: ...10 WIRING DIAGRAM ALU E43...
Page 11: ...11 WIRING DIAGRAM ALU E63...
Page 32: ...32...
Page 33: ...33...
Page 34: ...34...
Page 35: ...35 www zephyronline com HOTTE PER CUISINE Notice d utilisation ALU E43 ALU E63...
Page 41: ...41 SPECIFICATIONS TECHNIQUES ALU E43...
Page 42: ...42 ALU E63 SPECIFICATIONS TECHNIQUES...
Page 43: ...43 SCHEMA ELECTRIQUE ALU E43...
Page 44: ...44 SCHEMA ELECTRIQUE ALU E63...
Page 66: ...66...
Page 67: ...67...
Page 68: ...04308447 5...