background image

9

ELECTRICAL

WARNING

$OO(OHFWULFDOZRUNPXVWE\SHUIRUPHGE\TXDOL¿HGHOHFWULFLDQRUSHUVRQZLWKVLPLODUWHFKQLFDONQRZ

how and background.

For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use 
extension cord or adapter plug with this appliance.

Follow national electrical codes or prevailing local codes and ordinances.

Electrical Supply:

This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded 
branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ 
ground. Please also refer Electrical Diagram labeled on product.

Cable Lock:

$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKWDOVREHUHTXLUHGE\ORFDOFRGHV&KHFNZLWKORFDOUHTXLUHPHQWV

and codes, purchase and install appropriate connector if necessary.

Installation – 

Electrical

Cable Lock

Summary of Contents for AK7500BS

Page 1: ...Installation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JUN15 0301 2015 Zephyr Ventilation LLC Tempest II AK7500BS AK7536BS AK7542BS AK7548BS READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 roundto 3 1 4 x 10 rect transition 900 elbow 16 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 8 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 900 elbow 23 Ft x Ft ...

Page 3: ...tant to install the hood at the proper mounting height Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG UH KD DUG ZKLOH KRRGV mounted too high will be hard to reach and will ORVH LWV SHUIRUPDQFH DQG HI FLHQF If available also refer range manufacturer s height clearance requirements and recommended hood mounting height above range Vertical Ducting URXQG PLQLPXP VLQJOH LQWHUQDO EORZHU URXQG PLQ...

Page 4: ... garages All exhaust must be ducted to the outside Use metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV ZLWK FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Ducting Options Soffit or crawl space Roof Pitch w Flashing Cap Rear Ducting Side wall cap w gravity damper ...

Page 5: ... 4 7 7 8 or 9 15 16 R 9 16 7 7 8 or 10 3 8 1 15 16 or 4 5 16 11 9 16 10 3 4 3 3 16 7 7 8 10 3 8 9 7 8 9 1 2 14 3 16 7 7 8 or 9 15 16 Single Blower Rect Ducting Dimension Single Blower Round Ducting Dimension Dual Blower Dimension 1 11 16 29 7 8 30 35 7 8 36 41 7 8 42 47 7 8 48 C L C L Back View Mounting Dimensions 16 7 8 16 1 8 13 5 8 1 11 16 3 5 16 21 1 4 27 3 8 36 42 35 1 4 48 5 5 16 ...

Page 6: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock FDEOH ORFNLQJ FRQQHFWRU QRW VXSSOLHG PLJKW DOVR EH UHTXLUHG E ORFDO F...

Page 7: ... 4 AK7548BS 45 x 1 2 x 4 6 Prepare duct pipe and duct cut outs in upper cabinet if needed or ZDOO I KRUL RQWDOO GXFWLQJ KRRG 5HIHU WR KRRG VSHFL FDWLRQV RQ page 8 for dimensions 7 Prepare electrical wiring and electrical cut outs in upper cabinet if needed or wall if horizontal electrical hook up is required Refer to KRRG VSHFL FDWLRQV RQ SDJH IRU GLPHQVLRQV 0RXQW KRRG RQWR ZRRG ERDUG DQG VHFXUH X...

Page 8: ...h round rear ducting C This range hood is equipped standard with a 8 round vertical duct option To convert from 8 round vertical to 8 round horizontal ducting or 3 1 4 x 10 rectangular horizontal ducting please following the instructions below VERTICAL TO HORIZONTAL DUCTING CONVERSION Installation Single Blower Horizontal Ducting Conversion B 5HPRYH VFUHZV DWWDFKLQJ EORZHU WR EORZHU plate Turn blo...

Page 9: ...top of hood body From outside hood body attach top cover plate to top of hood body using VFUHZV 8 Connect blower plug Installation Single Blower Horizontal Ducting Conversion 5 Position single blower with single blower plate as shown Be sure to tuck back of single blower plate into tabs at back of hood Secure single EORZHU SODWH WR EDFN RI KRRG XVLQJ VFUHZV removed from step 2 ...

Page 10: ...step 3 This range hood is equipped standard with a single blower vertical duct option To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below 5 Position dual blower inside hood body as shown Be sure to tuck dual blower plate into EORZHU SODWH WDEV 6HFXUH GXDO EORZHU E screws previously removed from step 2 6 Attach 10 round blower colla...

Page 11: ...tisde hood body attach top cover plate to top of hood body using VFUHZV 8 Attach 10 inch round blower collar to back of KRRG XVLQJ 0 VFUHZV RQQHFW EORZHU wire extension cable to new blower and connect both plugs from each blower to female plugs behind switch panel A Installation PBD 1200A Dual Blower Horizontal Ducting Follow Steps 1 through 4 on page 13 then continue PBD 1200A horiztantal ducting...

Reviews: