19
Tempest I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Horizontal Ducting Conversion
This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round
vertical to 8” round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following
the instructions below.
NOTE:
Horizontal ducting is only available for the single internal blower.
NOTE:
If horizontally ducting via 3-1/4” x 10” rectangular ducting, the maximum airflow of 650 CFM
will be reduced to 550 CFM. Other CFM levels will not be affected.
1. Disconnect blower plug.
2. Remove (4) screws at top of
hood body attaching blower to
blower plate. Remove blower from
interior of hood body.