background image

INSTALLATION

SPECIFICATIONS

10"

22"

12"

4"

30"

            36"

CL

3-1/4"

10"

10"

             TOP VIEW

             REAR VIEW

10"

8-5/8"

4-1/2"

3-1/4"

1-1/8"

1"

1/2" Elec K.O.

1/2" Elec K.O.

10"

CL

3-1/4"

10"

10"

             TOP VIEW

             REAR VIEW

10"

8-5/8"

4-1/2"

3-1/4"

1-1/8"

1"

1/2" Elec K.O.

1/2" Elec K.O.

Models: AK7000, AK7036, AK7042    

Page 3

INSTALLATION

MOUNTING THE RANGEHOOD

ELECTRICAL

All Electrical work must by performed by qualified electrician or person with similar technical
know how and background.

For personal safety, remove house fuse or open circuit breaker before beginning installation.
Do not use extension cord or adapter plug with this appliance.

Follow National electrical codes or prevailing local codes and ordinances.

Electrical Supply:

This appliance requires a 120V 60Hz electrical supply., and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer Electrical Diagram labeled on product.

Cable Lock:

A cable locking connector (not supplied) might also be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary.

Cable Lock

WARNING 

Models: AK7000, AK7036, AK7042    

Page 4

Summary of Contents for AK7000

Page 1: ...overheat and catch fire The risk of self combustion is higher when the oil has been used several times Cleaning The saturation of greasy residue in the blower and filters may cause increased inflammab...

Page 2: ...ducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from open ing as possible If turns or transitions are required Install as far away from opening and as fa...

Page 3: ...ore beginning installation Do not use extension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requ...

Page 4: ...d check for leaks around duct tape duct silver tape 6 Duct opening cutout 4 Add 1x2 wood strips 3 Baffle filters INSTALLATION CONVERTIBLE OPTIONS Models AK7000 AK7036 AK7042 Page 6 This range hood is...

Page 5: ...dicator icon will flash indicating that you can still manually change speeds by selecting the or controls Standby Mode If the range hood was in auto mode prior to shutdown and detects any heat from be...

Page 6: ...eplacement they are required to be kept clean after approximately every 30 hours of use Removing Baffled Filters 1 Pull filter toward back of range hood using handles 2 Pivot filter front upward 3 Rem...

Page 7: ...bulbs filters and fuses Services outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The...

Page 8: ...lb is loose 1 Metal filter is loose 2 Spring clip is broken 1 The right upper corner of LCD display indicates HI 2 The right upper corner of LCD display indicates LO 3 The right upper corner of LCD di...