- 25 -
MOUNTING SCREWS
(4.8 x 38mm)
MOUNTING SCREWS
(3.9 x 6 mm Flat Head)
INSTALL DUCT COVERS
(DUCTED VERSION)
Purchase the optional Z1C-00IN Flue duct
cover, sold separately. The kit includes
the duct cover and duct cover mounting
bracket.
1.Assemble the duct cover mounting bracket,
adjusting outside width as shown (Fig.22).
2.Carefully center the mounting bracket
directly over the range hood location.
3.Secure the bracket assembly to the ceiling
using (2) 4.8 x 38mm mounting screws and
drywall anchors (Fig.23). Make sure the
bracket is pushed into the corner, tight
against the wall if necessary, and centered
over the hood.
4. Run metal ductwork to the outside location.
The metal duct must be 6-inch diameter
(version with internal blower) or 8-inch
diameter (version with an External or In-
Line blower). Fig. 24.
5. Install an appropriate wall or roof cap with
damper to exhaust the air to the outside.
6. Tape all duct joints with aluminum duct
tape.
DRYWALL
ANCHORS
FIG.22
FIG.23
11
3/4
”
FIG. 24
8”
METAL DUCT
Version internal blower
Version External or
In-Line Blower
6”
METAL DUCT