Lights On/Dim/Off

Display 

(speed level, delay off, filter clean/change)

Adjust 5 Speed Levels

Power / Delay Off

1  POWER / DELAY OFF BUTTON
       Power Button Function

       -      Button will turn power on and off for entire hood (fan and lights).
       - Hood will remember the last speed and light level it was turned off at.
 

(Example: Press      Button to turn off hood when on fan speed 4 and high lights. Press       Button  

 

again and the hood will turn back on at speed 4 and high lights level.)

     

  Delay Off Button Function

       - With the fan on press and hold      Button for two seconds. The fan will change to speed 1 and the 5  
         minute delay off timer will start.                 
                    +                                         LEDs will illuminate and slowly blink in accordance with the time  
         remaining until the fan and lights automatically turn off. 
        - Pressing      Button while Delay Off Function is enabled will turn the hood off and cancel the Delay  
         Off Function.

2  SPEED SELECTION BUTTON
       Fan Speed Decrease Button

       - Press this button to decrease fan speed. 5, 4, 3, 2, 1.
       - If fan is On Speed 1 and this button is pressed, fan will power Off.
 

      Fan Speed Increase Button

       - Press this button to increase fan speed. Fan On, 1, 2, 3, 4, 5.
       - If hood is Off and this button is pressed, fan will turn On Speed 1.   

3  LIGHTS BUTTON

     - Lights are two levels, High and Low.
     - From off, press one time for High. Press again for Low. Press again to power lights off.

4  DISPLAY INDICATORS
     Baffle Filter Clean Reminder 

(always enabled)

     - After 30 hours of fan usage, the       button indicator will begin to slowly blink indicating it is time to  
       clean the baffle filters. 
     -

 To reset:

 With hood off: hold the      button for three seconds. All LED indicators will blink two times  

       confirming the 30 hour timer has been reset.  

 

 

  

  

  

Features & Controls - 

ICON T

o

uch Controls

Summary of Contents for Siena Pro ZSP-E48AS

Page 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number APR14 0201 2014 Zephyr Corporation Siena Pro ZSP E48AS ...

Page 2: ...www zephyronline com ...

Page 3: ...unting Height Clearance 6 Ducting Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Range Hood 9 FEATURES CONTROLS ICON Touch Controls 10 MAINTENANCE Cleaning and Filter Care 11 Light Bulbs 12 TROUBLESHOOTING 13 WIRING FAN CURVE DIAGRAMS 14 LIST OF PARTS AND ACCESSORIES 15 Table of Contents ...

Page 4: ...are and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK D FORVH WWLQJ OLG FRRNLH VKHHW RU PHWDO WUD WKHQ WXUQ RII WKH EXUQHU 5 8 72 35 9 17 8516 I WKH ÀDPHV GR QRW JR RXW LPPHGLDWHO 9 8 7 1 7 5 3 570 17 b NEVER PICK UP A FLAMING PAN You may be burned c DO ...

Page 5: ...t the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances I FRGHV SHUPLW DQG D VHSDUDWH JURXQG ZLUH LV XVHG LW LV UHFRPPHQGHG WKDW D TXDOL HG HOHFWULFLDQ GHWHUPLQH WKDW WKH ground path is adequate Do not ground t...

Page 6: ...odes Duct cover extension accessory HARDWARE PACKAGE CONTENTS MODELS ZSP E48AS PARTS SUPPLIED 1 Hood with internal blower 3 Baffle filters 1 Duct cover assembly top and bottom 1 Duct cover wall bracket 3 50W halogen light bulbs 1 10 round collar with backdraft damper 1 Hardware package 1 Light Bulb Removal Suction Cup 4 M4 x 8 List of Materials ...

Page 7: ... 1 Duct pieces T otal Equivalent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct leng...

Page 8: ...l be hard to reach and will ORRVH LWV SHUIRUPDQFH DQG HI FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 15 for part number and ordering information DAMAGE SHIPMENT INSTALLATION 3OHDV...

Page 9: ... to the outside unless using the recirculating option Use single wall rigid Metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap side wall cap w gravity damper ...

Page 10: ...com Installation RRG 6SHFL FDWLRQV Top of Hood Side of Hood Front of Hood AC In C L 16 11 16 47 7 8 11 5 16 STANDARD min ducted 27 1 2 max 42 Z1C 00SP min ducted 45 max 78 12 3 16 21 15 16 1 9 16 6 3 4 9 15 16 6 9 16 1 3 ...

Page 11: ...R VFUHZV DQG KDQG WLJKWHQ 8VH the last M4 x 1 1 2 screws to further secure the hood to the ZDOO IURP LQVLGH WKH KRRG 8 Center and attach duct cover bracket to wall below ceiling RU VRI W XVLQJ 0 VFUHZV 9 Install electrical 10 Install duct work and duct tape 11 Power up hood and check for leaks around duct tape 12 Place telescopic duct covers onto hood and extend inner WRS GXFW FRYHU XSZDUGV DQG VH...

Page 12: ...turn off Pressing Button while Delay Off Function is enabled will turn the hood off and cancel the Delay Off Function 2 SPEED SELECTION BUTTON Fan Speed Decrease Button Press this button to decrease fan speed 5 4 3 2 1 If fan is On Speed 1 and this button is pressed fan will power Off Fan Speed Increase Button Press this button to increase fan speed Fan On 1 2 3 4 5 If hood is Off and this button ...

Page 13: ...product containing chlorine bleach Do not use orange cleaners DIÀH LOWHUV 7KH EDIÀH OWHUV LQVWDOOHG E WKH IDFWRU DUH LQWHQGHG WR OWHU RXW UHVLGXH DQG JUHDVH IURP FRRNLQJ 7KH need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing detergent and leave to soak if heavily soiled U OWHUV DQG UH LQVWDOO EHIRUH XVLQJ...

Page 14: ...turned off and bulbs are not hot 5HPRYH E WXUQLQJ EXOE FRXQWHU FORFNZLVH 1RWH XOE GRHV QRW XQVFUHZ LW WXUQV GHJUHHV stops and falls out I EXOEV DUH GLI FXOW WR WXUQ GXH WR SURORQJHG XVH UPO DWWDFK WKH LQFOXGHG JODVV VXFWLRQ FXS RU XVH D UXEEHU latex glove grip and turn the bulb counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For part n...

Page 15: ...RQ GMXVW WKH OWHUV XQWLO WKH ZKLVWOLQJ VWRSV 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connections to be sure all connections are sealed properly The blower is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The halogen bulb wire is loose 2 Check bulb wire connections at the control board and the light bulbs Reconnect...

Page 16: ...ssure inAq Blower Fan Curve Model ZSP E48AS AC Input 120V 60Hz Outlet Diameter 10in 0 00 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 Flow rate CFM VOLTS HZ MAX AMPS 120 60 9 USEONLYTYPEMR16 GU10 50W MAX HALOGENLIGHTBULBS ZSP E48AS CIRCUIT DIAGRAM ...

Page 17: ...H LOWHU HDFK DORJHQ LJKW EXOE HDFK Optional Accessories Duct Cover Extension Kit Z1C 00SP Universal Make Up Air Damper MUA010A To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 List of Parts Accessories ...

Page 18: ...irst year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PR...

Page 19: ...Guide d utilisation d entretien et d installation www zephyronline com Model number Serial Number APR14 0201 2014 Zephyr Corporation Siena Pro ZSP E48AS ...

Page 20: ...www zephyronline com ...

Page 21: ...ns d installation pour le conduit 7 6SpFL FDWLRQV GH OD KRWWH 8 Montage de la hotte 9 COMMANDES ET CARACTÉRISTIQUES ICON Commandes 10 ENTRETIEN 1HWWR DJH HW HQWUHWLHQ GHV OWUHV 11 Ampoules 12 DÉPANNAGE 13 DIAGRAMMES DES COURBES CARACTÉRISTIQUES DES VENTILATEURS 14 ET SCHÉMA DE CÂBLAGE LISTES DES ACCESSOIRES ET DES PIÈCES 15 Table des matières ...

Page 22: ...as la hotte sans surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et à la quantité de nourriture que vous préparez AVERTISSEMENT POUR RÉDUIRE LES RISQUES DE BLESSURE LORS D UN INCENDIE SUR LA SURFACE DE CUISSON a ÉTOUFFEZ LES FLAMMES avec un couvercle une plaque à biscuits ou un plateau de métal et éteignez ensuite le brûleur PRENEZ...

Page 23: ...FLHQ TXDOL p S assurer que l installation électrique est adéquate et qu elle respecte le Code national de l électricité la plus récente édition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien de l électricité section 1 la plus récente édition du code C22 2 No 0 M91 ainsi que tous les codes et réglements en vigueur 6L OHV FRGHV SHUPHWWHQW O XWLOLVDWLRQ G XQ O GH JDUGH LVROp HW TXH YR...

Page 24: ...ouvrement de conduit CONTENU DE LA TROUSSE DE QUINCAILLERIE MODÈLES ZSP E48AS PIÈCES FOURNIES 1 Hotte avec ventilateur interne 2 Filtres déflecteurs 1 Ensemble de recouvrement de conduit parties supérieure et inférieure 1 Support mural pour le recouvrement de conduit 2 Ampoules halogènes 50W 1 Registre antirefoulement circulaire de 10 1 Trousse de quincaillerie 1 Ventouse pour enlever des ampoules...

Page 25: ...isé 6 embout mural circ registre 30 pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude à 90º 15 pi x pi 7 or 10 7 or 10 circ coude à 45º 9 pi x pi pi pi pi 6 chapeau de toiture circ 30 pi x pi 7 or 10 circ chapeau de toiture 30 pi x pi Sous total colonne 2 Sous total colonne 1 Total du conduit Longueur maximale du conduit d aération Pour un mouvement d air convenable la longueur tota...

Page 26: ...OHXU HI FDFLWp HW OHXU UHQGHPHQW UpGXLWV Si elles sont disponibles consultez les exigences de hauteur d espace libre requise par le fabricant de la cuisinière ainsi que la hauteur recommandée de montage de la hotte au dessus de la surface de cuisson Informez vous toujours des normes et des réglementations locales en vigueur pour toute différence par rapport aux normes du fabricant Ensemble de reco...

Page 27: ...que l option de recirculation d air ne soit utilisée N utilisez que des conduits en métal pour cloison simple Fixez toutes les pièces du conduit avec des vis à tôle et isolez tous les joints avec du ruban adhésif en toile ou GX UXEDQ UpÀHFWHXU FHUWL p 4XHOTXHV RSWLRQV SRXU OH FRQGXLW G DpUDWLRQ Bouche d aération de mur latéral avec clapet antirefoulement Retombée de plafond ou vide sanitaire Pente...

Page 28: ...L FDWLRQV GH OD KRWWH Dessus de la hotte Côté de la hotte Devant de la hotte Entrée élec L C STANDARD min avec conduit 27 1 2 max 42 Z1C 00SP min avec conduit 45 max 78 12 3 16 21 15 16 1 9 16 6 3 4 9 15 16 6 9 16 1 16 11 16 47 7 8 11 5 16 3 ...

Page 29: ...V ORFDOHV DYDQW G XWLOLVHU GH WHOV GLVSRVLWLIV H IDLW GH QH SDV XWLOLVHU GHV DQFUDJHV PXUDX HW GHV YLV FRQYHQDEOHV SRXU VRXWHQLU OH SRLGV GH OD KRWWH SRXUUDLW HQWUDvQHU GHV EOHVVXUHV RX HQGRPPDJHU OD VXUIDFH GH FXLVVRQ RX OH FRPSWRLU 6 Installez le collier du conduit circulaire de 10 avec registre antirefoulement sur la partie supérieure du bâti de la hotte à l aide de quatre 4 vis à tête plate M4...

Page 30: ...ateur et des lumières Appuyez sur la touche lorsque la fonction d arrêt à retardement est en cours d utilisation pour éteindre la hotte et annuler la fonction d arrêt à retardement 2 TOUCHE DE CHOIX DE VITESSE Touche de réduction de vitesse du ventilateur Appuyez sur cette touche pour réduire la vitesse du ventilateur 5 4 3 2 1 Si le ventilateur est à la vitesse 1 et que vous appuyez sur cette tou...

Page 31: ...nts nettoyants orange LOWUH GpÀHFWHXUV HV OWUHV GpÀHFWHXUV LQVWDOOpV SDU OH IDEULFDQW RQW SRXU IRQFWLRQ GH OWUHU OHV UpVLGXV HW OD JUDLVVH GH cuisson Ils ne nécessitent aucun remplacement sur une base régulière mais doivent être gardés propres Enlevez les et nettoyez les à la main ou au lave vaisselle avec de l eau tiède Vaporisez avec du détergent pour graisse et laissez tremper pour éliminer la ...

Page 32: ...ans le sens contraire des aiguilles d une montre Note les ampoules ne se dévissent pas après une rotation de 60 degrés elles s arrêtent et tombent de la douille RUVTX LO HVW GLI FLOH GH UHWLUHU OHV DPSRXOHV DSUqV XQ XVDJH SURORQJp H XQH YHQWRXVH FRUUHVSRQGDQW SOXV RX moins à la taille de l ampoule ou utilisez des gants en latex ou en caoutchouc et tournez dans le sens inverse des aiguilles d une m...

Page 33: ...s des tuyaux ne sont pas bien scellés ou les conduits ne sont pas connectés adéquatement 9pUL H OHV MRLQWV GX FRQGXLW SRXU YRXV DVVXUHU TX LOV sont adéquatement scellés Le moteur fonctionne mais pas les lumières 1 L ampoule halogène est défectueuse 1 Remplacez l ampoule halogène 2 Le câble de l ampoule halogène est desserré 9pUL H OHV FRQQH LRQV GHV FkEOHV GH O DPSRXOH DX tableau de commande et au...

Page 34: ...14 www zephyronline com LDJUDPPHV GHV FRXUEHV FDUDFWpULVWLTXHV GHV YHQWLODWHXUV HW VFKpPD GH FkEODJH 9 ...

Page 35: ...HPHQW LOWUH GpÀHFWHXU XQLWp Ampoule halogène de 50W unité Z0B 0020 FFHVVRLUHV RSWLRQQHOV Trousse de prolongement de recouvrement de conduit Z1C 00SI Pour commander des pièces visitez notre site Web au http www zephyronline com ou communiquez avec nous par téléphone au 1 888 880 8368 ...

Page 36: ...êtes également responsable de tous les frais de main d œuvre associés à la présente garantie Restrictions de la garantie NOTRE OBLIGATION DE RÉPARER OU DE REMPLACER À NOTRE GRÉ LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PRÉSENTE GARANTIE NOUS NE NOUS PORTONS PAS RESPONSABLES POUR TOUT DOMMAGE INDIRECT ACCESSOIRE OU PARTICULIER RÉSULTANT OU AYANT UN LIEN AVEC L UTILISATION OU LE REND...

Reviews: