background image

 

 
 
 
 
 
 
 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

Brushless DC Tubular Motor 

Operation Manual 

Tubular Motor Type

  SS40E 

Remote Control Type

  ZEN16SA

ZEN16DA 

Summary of Contents for SS40E

Page 1: ...Brushless DC Tubular Motor Operation Manual Tubular Motor Type SS40E Remote Control Type ZEN16SA ZEN16DA ...

Page 2: ...ween Motor and Remote Control 14 Cancel the Connection 15 Switch Between Forward and Reverse Rotations 16 Set Upper and Lower limits 17 Set Group Control 19 Duplicate Remote Control 21 Cancel Other Remote Control 22 Set Cancel Preferred Position 23 Operate Preferred Position 24 Quick Command Guide 25 Miscellaneous Troubleshooting 27 Illustration of Wiring 28 Appendix 29 ...

Page 3: ...hildren to play with fixed controls Keep remote controls away from children Frequently examine the installation for imbalance and signs of wear or damage to cables and springs Do not use if repair or adjustment is necessary Full all pole disconnection from the supply mains must be provided in the fixed wiring in accordance with the wiring rules Caution To reduce the fire risk of electric shock or ...

Page 4: ...tube so that the motor may drive the aluminum tube to rotate 2 Code Button It is for setting the communication code between the remote control unit and the tubular motor 3 Crown 4 Antenna It is for receiving instructions from the remote control unit 5 AC Power Cord Name of Each Part 1 2 3 4 5 ...

Page 5: ...battery E OK a confirm key during group control settings F Window number frame selection the currently promoted window number 2 Channel selection buttons To select window channel or group channel or All 3 ENTER To confirm channel selected 4 UP To lift blinds upward 5 STOP To stop blinds movement or move blinds to preferred position or switch between forward and backward rotations 6 DOWN To move bl...

Page 6: ...vates other electronic appliances please contact the distributor Caution FCC ID YUYSSRC002 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly app...

Page 7: ...lation of motorized blinds Cylindrical Aluminum Tube Inside diameterφ40 Slot size 13 5 Molded Aluminum Tube ATD46 Molded Aluminum Tube ATD50 A plastic ring for ATD50 is required Molded Aluminum Tube ATD51 A ring for ATD51 is required Molded Aluminum Tube ATO43 Specified tube for venetian blinds ...

Page 8: ...sten the tube at the motor end with screws not a necessity may skip this step 5 Inset the idler wheel onto tube Cylindrical Aluminum Tube Molded Aluminum Tube Position for inserting the Positioning Pin of the Crown Positions for mounting the screws ...

Page 9: ...stalling the brackets to the target position in the curtain box or on the wall 8 Install the motorized blinds Install the motorized blinds onto the brackets 9 Connect to the electric power Connect power cord to AC power before setting and operation Positions for mounting the screws Notice The positioning slot should be firmly fixed into the bracket ...

Page 10: ... control is ready for using after battery icon disappear 3 2 In User Mode appear Group Channels Window Channels and All 5 Low battery It could not do settings while the battery icon flashes please change a new one immediately 4 If All is selected Group Channels and Window Channels will disappear About the battery The battery provided with the product is prepared for your initial use For the batter...

Page 11: ...de when the motor is ready to be operated 2 To switch between Setting Mode and User Mode should be achieved on the remote control 3 Mode check the screen appears Group Channels G1 G4 Window Channels 1 16 and All Switch Setting Mode User Mode Setting Mode User Mode The LCD screen appears Window Channels 1 16 ...

Page 12: ...lection Switch close the battery cover immediately Notice Unless the motor requires reset please keep the Mode Selection Switch in User Mode Schematic Diagram of Mode Selection Switch Setting Mode The switch is at the right position User Mode The switch is at the left position 3 After the mode selection is completed close the battery cover immediately 1 Open the battery cover 2 Toggle the Mode Sel...

Page 13: ...ote control to Setting Mode To enter Roller system press both UP Enter for 2 seconds until the cursor lit To enter Venetian system press both DOWN Enter for 2 seconds until the cursor lit Press the Up button and Enter button simultaneously Press the Down button and Enter button simultaneously Roller system Default Venetian system Switch blinds system Notice Once the system has been chosen all chan...

Page 14: ... needs to be connected 3 Code To establish a connection between the motor and the remote control Press Code on the motor for 1 second the motor will respond beep Set Connection Between Motor and Remote Control Press the Code to start code identification Press any button of to move cursor to the target channel ...

Page 15: ...otor for 5 seconds when the motor responds with a beeping sound the connection to all remote controls has been cleared Beep Press Code for 5 seconds to cancel the connection Notice Unless it is necessary to establish connection again please do not press the Code for more than 2 seconds To avoid interference please set the connection one by one in the same building Cancel Connection Press the Up an...

Page 16: ...r switching between forward and backward rotation is complete Switch Between Forward and Backward Beep Press Stop for 3 seconds Notice Unless it is necessary to change the rotation direction please do not press Stop for more than 3 seconds It requires to reset the upper lower limit again if the rotation direction has been changed after the setting of upper lower limit is complete ...

Page 17: ...e Upper Limit Use remote control to lift blinds at the target position for setting the upper limit During this operation please perform Switch Between Forward and Backward Rotations if necessary Press Stop and Enter simultaneously when the motor responds with a beeping sound the upper limit setting is complete Set Upper Lower Limit Press Stop and Enter simultaneously Beep Press Up and Stop simulta...

Page 18: ...imultaneously when the motor responds with a beeping sound the lower limit setting is complete 6 If need to reset the upper lower limit again please repeat Step 2 3 or Steps 4 5 Notice After the Upper Lower Limit Setting is complete please toggle the Mode Selection Switch back to User Mode If need to reset the limit position either upper limit setting or lower limit setting could be executed separ...

Page 19: ...A remote control provides up to 4 groups to perform 3 Enter group setting Press Enter for 3 seconds to enter group setting Set Group Control Press Enter for 3 sec Select group Select target group then the selected group channel is flash Press any of them to move cursor Enter group setting Press Enter for 3 seconds until the group icon G2 G4 disappear and G1 is flash ...

Page 20: ... OK and press Enter to complete the group setting 7 To add or to remove window from a group Follow by the above step 1 to step 4 press Enter to join the new window and the cursor stay on the new joined window Press Enter to remove the joined window the cursor become flash on the removed window Join windows in the group Press Enter to join window in this group Confirm group Move cursor to OK and pr...

Page 21: ...o press shortly on the Copy button located above the battery when the motor responds with a beep sound then the motor is ready to be connected 4 Select a channel on RM B which will connect to the motor 5 Press Up and Down on RM B simultaneously it completes receiving codes when the motor responds with beep sound Duplicate Remote Control Use a thin rod to press shortly on the Copy button To start c...

Page 22: ... a thin rod to press for 3 seconds on the Copy button located above the battery when the motor responds with a beep sound then the connections between motor and the other remote controls has been deleted except for the preserved one Cancel Other Remote Controls Use a thin rod to press for 3 sec on the Copy button Each time to duplicate or delete remote controls only one channel is allowed Please r...

Page 23: ...ift blinds to target preferred positions Press Stop and Enter simultaneously it is complete when motor responds with beep sound 5 Notice If 2 preferred positions are configured the motor will not receive the command Set the Preferred Position any more 6 If need to change the preferred position please cancel one of the preferred position first Press Stop and Enter simultaneously Notice Before setti...

Page 24: ...inds will move to this preferred position Two preferred positions press Stop for 3 seconds the blinds will move to nearest preferred position press Stop for 3 seconds again the blinds will move to another preferred position Press Stop for 3 seconds Beep Notice Please make sure the Mode Selection Switch has been toggled to User Mode if need to move to preferred position Move to Preferred Position ...

Page 25: ...5 Cancel Connection Press Code for 5 sec P15 Switch Between Forward and Backward Rotations Press Stop for 3 sec P16 Set the Upper Lower Limit 1 Press Stop and Up to enter setting mode 2 Press Stop and Enter to set upper limit 3 Press Stop and Down to enter lower limit 4 Press Stop and Enter to set lower limit P17 18 Duplicate Remote Control 1 Press Copy on the revised side on the original remote c...

Page 26: ...roup control setting mode 2 Select windows and press Enter to join in the group 3 Move to OK then press Enter to confirm group setting P19 20 Set Preferred Position Press Stop and Enter P23 Cancel Preferred Position Press Stop and Enter P23 Move to Preferred Position Press Stop for 3 sec P24 ...

Page 27: ...rol is running out of energy Replace the battery Remote control mode error Switch the operation mode Remote control is damaged Contact the distributor for service Motor is damaged Contact the distributor for service No beeping sound during the setting operation Buzzer is damaged Contact the distributor for service Cannot rotate to the target position Motor is damaged Contact the distributor for se...

Page 28: ...amage of the motor 2 After wire 1 and wire 2 are connected short circuited 1 2 seconds the motor will turn down 3 After wire 1 and wire 4 are connected short circuited 1 2 seconds the motor will turn up 4 After wire 1 and wire 3 are connected short circuited the motor stop immediately SWITCH SWITCH SWITCH 1 27V 2 DOWN 3 STOP 4 UP RJ 14 Jack 6P4C Reference of External layout If any external connect...

Page 29: ...onditions for indoor use only room temperature 0 40 humidity 60 90 RH Storage conditions to store horizontally in temperature 10 45 Favorable loads within 15 Rating operation duration 1 hour ZEN16SA Remote Control 16 channel multi window control Power Supply input DC 6V CR 2032 Dimensions 155 mm 長 50 mm 寬 16 mm 高 Power Consumption 10μA Emission frequency ASK 433 92 MHz Code set more than 16 millio...