SAFETY INSTRUCTIONS AND ADDITIONAL NOTES 

  Installation should only be performed by qualified professionals according to the laws and regulations applicable in each country. 

  Do not connect the mains voltage nor any other external voltage to any point of the KNX bus; it would represent a risk for the entire KNX system. The 

facility must have  enough  insulation  between  the  mains (or  auxiliary)  voltage  and  the  KNX  bus  or  the  wires  of  other  accessories, in  case of  being 
installed. 

  Once the device is installed (in the panel or box), it must not be accessible from outside. 

  Keep the device away from water (condensation over the device included) and do not cover it with clothes, paper or any other material while in use. 

  The  WEEE  logo  means  that  this  device  contains  electronic  parts  and  it  must  be  properly  disposed  of  by  following  the  instructions  at 

https://www.zennio.com/en/legal/weee-regulation. 

OUTPUTS SPECIFICATIONS AND CONNECTIONS 

CONCEPT 

DESCRIPTION 

Number of outputs 

Output type 

Potential-free  outputs  through  bistable  relays 
with tungsten pre-contact / Micro-disconnection 

Rated current per output 

AC 16(6)A @ 250VAC (4000VA) 
DC 7A @ 30VDC (210W) 

Maximum load 
per output 

Resistive 

4000W 

Inductive 

1500VA 

Maximum inrush current 

800A/200μs 
165A/20ms 

Connections in adjacent outputs  

Possibility of  connecting  different  phases.  It is 
not  allowed  to  connect  power  supplies  of 
different  order,  SELV  with  NO  SELV,  in  the 
same block  

Maximum current per block 

40A 

Connection method 

Screw terminal block 

Cable cross-section 

1.5-4mm² (IEC) / 26-10AWG (UL) 

Outputs per common 

Maximum response time 

10ms 

Mechanical lifetime (min. cycles) 

3 000 000 

Electrical lifetime (min. cycles)

100000 @ 8A / 25000 @ 16A (VAC) 

¹ Lifetime values could change depending on the load type. 

 

0-10V OUPUT SPECIFICATIONS AND CONNECTIONS 

CONCEPT 

DESCRIPTION 

Número de salidas 

Ouput type 

0..10VDC 

Maximum load per output 

1.5mA 

Connection method 

Screw terminal block  

Cable cross-section 

0.5-2.5mm² (IEC) / 26-12AWG (UL) 

Output per common 

 

INPUTS SPECIFICATIONS AND CONNECTIONS 

CONCEPT 

DESCRIPTION 

Number of inputs 

Inputs per common 

Operation voltage 

+3.3VDC in the common 

Operation current 

1mA @ 3.3VDC (per input) 

Switching type 

Dry  voltage  contacts  between  input  and 
common 

Connection method 

Screw terminal block 

Cable cross-section 

0.5-2.5mm² (IEC) / 26-12AWG (UL) 

Maximum cable length 

30m 

NTC probe length 

1.5m (extensible up to 30m) 

NTC accuracy (@ 25°C) 

±0.5°C 

Temperature resolution 

0.1°C 

Maximum response time 

10ms 

 

 In order  to ensure the  expected  status of  the relays, 

please check that the device is connected to the KNX bus 
before energizing the power circuit. 
 

WIRING DIAGRAMS 

Figure 2: (From up to down and from left to right) 

Terminal block 1 and 0-10V outputs wiring examples 

for two valves, two fans, one valve and one fan. 

Attaching MAXinBOX FC 0-10V FAN to DIN rail: 

Removing MAXinBOX FC 0-10V FAN from DIN rail: 

* In case of using ZN1IO-DETEC-P sensor, its micro switch number 2 must be in 

Type B position

INPUTS CONNECTION 

Any combination of the following accessories is allowed in the inputs: 

Zennio  temperature 
probe.

 

 

 

Up  to  two  motion  sensors 
can  be  plugged  into  the 
same  device  input  (parallel 
wiring).

 

 

 

Screw 

terminal 

for 

connecting  Zennio  motion 
sensors*.

 

 

Temperature Probe

 

Motion Sensor

 

 

 

Switch/Sensor/ 

Push button

 

 

 

Commons  of  different  devices 
must not be connected together.

 