CONFIGURATION
5.1
GENERAL
After importing the corresponding database in ETS and adding the device into the
topology of the desired project, the configuration process begins by right-clicking into
the device and selecting
Edit parameters
.
ETS PARAMETERISATION
The only parameterisable screen available is
“General”. From this screen it is possible
to configure all the required functionality.
Figure 5.
General Configuration.
Opening Time
: time the lock remains open after receiving the opening
command. Range: 10 to 255 tenths of a second (30 by default). The
maximum recommended opening time will depend on the lock type.
Heartbeat (Periodical Alive Notification)
: incorporates a one-bit object to
the project (“
[Heartbeat] Object to Send ‘1’
”) that will be sent periodically
with a value of “1” to notify that the device is still working (still
alive
).
Figure 6.
Heartbeat (Periodical Alive Notification).