Zennio Securel ZIO-SEC User Manual Download Page 10

 

 

 

Securel

 

http://www.zennio.com

 

            

Technical Support:

 

http://support.zennio.com

 

 

10

 

5

 

CONFIGURATION 

5.1

 

GENERAL 

After  importing  the  corresponding  database  in  ETS  and  adding  the  device  into  the 

topology  of  the  desired  project,  the  configuration  process  begins  by  right-clicking  into 

the device and selecting 

Edit parameters

ETS PARAMETERISATION 

The only parameterisable screen available is 

“General”. From this screen it is possible 

to configure all the required functionality. 

 

Figure 5. 

General Configuration. 

 

Opening  Time

:  time  the  lock  remains  open  after  receiving  the  opening 

command.  Range:  10  to  255  tenths  of  a  second  (30  by  default).  The 

maximum recommended opening time will depend on the lock type. 

 

Heartbeat  (Periodical  Alive  Notification)

:  incorporates  a  one-bit  object  to 

the  project  (“

[Heartbeat]  Object  to  Send  ‘1’

”)  that  will  be  sent  periodically 

with a value of “1” to notify that the device is still working (still 

alive

). 

 

Figure 6.

 Heartbeat (Periodical Alive Notification). 

Summary of Contents for Securel ZIO-SEC

Page 1: ...Securel Access Controller Encrypted Relay ZIO SEC USER MANUAL ds kmfroi Application Program Version 1 1 User manual edition 1 1 _a www zennio com...

Page 2: ...3 1 1 Securel 3 1 2 Access Control System 4 1 3 Installation 4 2 Pairing with IWAC 7 3 LED Notification 8 4 Securel status 9 4 1 Default status 9 4 2 Status after programming 9 4 3 Status after bus fa...

Page 3: ...d it uses encrypted information to communicate with the access control device known as IWAC In this way the inviolability of the system is assured The most notable features of this device are Acting o...

Page 4: ...pen command is correctly received from IWAC access granted Securel will release the lock for a while to open the door BMS Building Management System computer system that assumes the integral automatio...

Page 5: ...onnectors 3 On the other hand Securel powers the electric strike also using one of the other positive supply terminals 1 and the terminal of the electric strike output as neutral 2 Moreover the relay...

Page 6: ...trol system it is necessary to locate Securel inside the room of the management module establishing an encrypted communication with IWAC To get detailed information about the technical features of thi...

Page 7: ...h any IWAC before it will be in pairing mode Only connect the Securel to the IWAC desired to pair with and they will be automatically paired If Securel is paired with an IWAC press the programming but...

Page 8: ...door closed When the programming mode is activated only this mode will be notified by lighting the LED in red Note Securel can be paired or open close the relay while the programming mode is active bu...

Page 9: ...any action on the lock until a first order is received from the IWAC If Securel was not paired remains in pairing mode 4 3 STATUS AFTER BUS FAILURE A KNX bus power failure does not imply any change in...

Page 10: ...is General From this screen it is possible to configure all the required functionality Figure 5 General Configuration Opening Time time the lock remains open after receiving the opening command Range...

Page 11: ...ter download or bus failure takes place with a delay of up to 255 seconds to prevent bus overload The following sendings match the period set Note Take into account that Securel must be paired with th...

Page 12: ...other values permitted by the bus according to the object size may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the applicatio...

Page 13: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: