Flat 55 Display 

http://www.zennio.com

 

Technical Support: 

http://support.zennio.com 

 

64 

The boxes in the screen can be assigned different functions, as described next. 

ETS PARAMETERISATION 

An independent tab for the parameterisation of the Display is shown in ETS by default. 

While all the zones remain disabled, it will only contain a sub-tab named Configuration. 

This display contains the following parameters: 

 

Page  Style 

[

Normal Page 

/  Thermostat

]:  sets  the  layout  and functionality  of 

the display.  

 

Figure 47. 

Display 

– Configuration (Normal Page). 

Summary of Contents for FLAT 55

Page 1: ...Flat 55 Display 55x55mm Capacitive Glass Touch Panel with Round Display55x55mm with round display ZVI F55D USER MANUAL Application Programme Version 2 0 User Manual Version 2 0 _a www zennio com...

Page 2: ...on 8 2 1 2 Advanced Configuration 16 Buttons 24 2 2 1 Configuration 24 2 2 2 Disable 27 2 2 3 Individual 27 2 2 4 Pair 47 Display 62 2 3 1 Configuration 62 2 3 2 Disabled 66 2 3 3 Individual 66 2 3 4...

Page 3: ...UPDATES Version Changes Page s 2 0 _a Changes in the application program New page style Thermostat 63 66 77 79 Parameter to include plus sign before positive setpoints 72 Temperature Probe new option...

Page 4: ...emented by the built in analogue digital inputs and the thermostat function as well as an elegant and fully customisable design of the front glass customers can choose their button icons texts and col...

Page 5: ...e Screensaver function Two analogue digital inputs for motion detectors temperature probes additional switches etc Thermostat function Celsius and Fahrenheit temperature scales for the on screen indic...

Page 6: ...D 6 will light in red On the contrary if this button is held while plugging the device into the KNX bus the device will enter the Safe Mode In such case the programming LED will then blink in red For...

Page 7: ...y to wait for 2 minute without performing any action in order to make it possible a proper calibration of Proximity sensor Luminosity sensor Button presses For a correct calibration of the proximity a...

Page 8: ...ng the Parameters tab of the device GENERAL In order to allow the device to perform the desired functions a number of options must be parameterized either related to its general behavior screensaver s...

Page 9: ...ostat tab in the tree on the left See section 2 5 for details Heartbeat Periodic Alive Notification disabled enabled incorporates a one bit object to the project Heartbeat Object to Send 1 that will b...

Page 10: ...es or disables the possibility of locking the touch by object When enabled a new tab is added in the tree on the left see section 2 1 1 3 Proximity Sensor disabled enabled enables the proximity sensor...

Page 11: ...he internal time of the device for example by linking it to a KNX clock This object also allows read requests so the current time of the device can be checked It is also automatically sent after time...

Page 12: ...screen if the proximity sensor is activated It can be set by parameter if while the screen saver is active pressing the touch panel will only cause the screen saver to be interrupted or if the action...

Page 13: ...ded for this purpose It can also be done through scene values While locked user presses on the touch buttons will be ignored no actions will be performed when the user presses on any of the controls H...

Page 14: ...nd Proximity Sensor available in the Flat 55 Display product section at the Zennio homepage www zennio com for detailed information about the functionality and the configuration of the related paramet...

Page 15: ...configuration of Sounds from Configuration screen see section 2 1 1 a new tab will be incorporated into the tree on the left The initial configuration of this screen is equivalent to the default sett...

Page 16: ...enabled a specific object General Sounds Doorbell will be included into the project topology Value 0 No Action 1 Doorbell 0 Doorbell 1 No Action parameter to select which value should trigger which a...

Page 17: ...eit The selected scale applies to any temperatures shown on the screen such as The screensaver temperature Indicators of temperature controls linked to a box in the display Climate Temperature setpoin...

Page 18: ...35 s 1 65535 min h timeout to deactivate the cleaning function once triggered Displayed Cleaning Icon disabled enabled sets whether to show a cleaning icon during the cleaning state When Display Clean...

Page 19: ...ears when touching the screen or ending the welcome greeting with the object Note Welcome greeting takes precedence over screensaver When the welcome greeting is displayed the screensaver will be disa...

Page 20: ...OBJECT Flat 55 Display can send a specific object a one bit value a scene value or both depending on the parameterisation to the KNX bus when the user presses a touch button or when the proximity sen...

Page 21: ...not send unless all additional conditions are 1 the welcome back object will only be sent if all the condition objects are found to have the value 1 Do not send unless at least one of the additional...

Page 22: ...brightness level can be attenuated during night mode The warning can be stopped muted by pressing a button However as long as the warning remains active when the device goes into inactivity the icon...

Page 23: ...hould blink or not during the warning Enable Acoustic Notification enabled disabled sets whether there will be an intermittent sound or not during the warning Enable Attenuation During Night Mode enab...

Page 24: ...ossible to combine any two of them within one pair The opposite corner buttons cannot be configured as a pair All the buttons are identical this brings a high level of versatility for a wide variety o...

Page 25: ...stant Dimmer Shutter Enumeration Climate Fan Climate Mode Climate Mode Special Room State Apart from the button function itself the integrator can select the desired behaviour of the button LEDs The d...

Page 26: ...cting this option brings a new tab Button X which will make it possible to configure the functionality of that particular touch button See section 2 2 3 for details Pair X Sets that this touch button...

Page 27: ...Right On Up Increment Right Off Down Decrement Left On Up Increment Every button pair is configured separately there will be a specific parameter in every two button control for specifically selectin...

Page 28: ...l be used in each case Under a State dependent LED illumination the LED will remain on off according to the current state on off of either one object or the other which can be configured in parameters...

Page 29: ...control that sends orders to the KNX bus which can then be executed by light dimmers These orders consist in Switch on Switch off orders on short presses Step dimming orders on long presses and the su...

Page 30: ...the move and the step orders after every long press However there are some exceptions to this alternation On a short press a step up order will be sent if the last long press made the shutter move up...

Page 31: ...ject is initialised with value 50 after a download or a bus failure therefore the actuator is required to update it with the real value after the bus recovery The state dependent LED illumination mode...

Page 32: ...tion controls the object is sent to the bus slightly delayed once the desired value has been set by the user For these two cases it is possible to link the control with a box in the display in order t...

Page 33: ...urrent object value coincides with the parameterized value ETS PARAMETERISATION When an individual button has been enabled a specific tab Button In becomes available under Buttons in the tree on the l...

Page 34: ...e value to switch off and on the LED shows up Figure 14 LED illumination control Dedicated object Note this parameter will remain hidden unless having selected Configure every button pair separately i...

Page 35: ...t topology so that the values that determine the state of the LED at a given time can be received from the bus Switch Figure 17 Individual Button Switch Action Send 0 Send 1 Toggle 0 1 sets the value...

Page 36: ...on Long press Send 0 Send 1 Toggle 0 1 Send 1 byte Unsigned Int Value sets the value to be sent to the bus through Btn In Two Objects Long Press when the user long presses the button In case of selec...

Page 37: ...o the bus both in the case of the run requests and the save requests Object to Use General Scene Object Individual Control Scene Object commands are sent via the general scene object General Scene Sen...

Page 38: ...Signed Int Value Unsigned 0 65535 Btn In 2 Byte Unsigned Int Value Float 2 Bytes 671088 64 0 670760 96 Btn In 2 Byte Float Value Table 4 Constant type numerical control LED Illumination Control Regul...

Page 39: ...t object while the alternating step up down orders will be through the Btn In Shutter Stop Step one bit object Additionally a one byte object Btn In Shutter Position is provided to link it to the posi...

Page 40: ...sent through the control object when the user after pressing the buttons sets the control to state j The actual sending will not be performed until 1 5 seconds after the last press Link the control w...

Page 41: ...one byte object Btn In Fan Control Type Enumeration Cyclical enabled disabled sets whether scrolling through the speed levels is circular or not If checked a press switches to the minimum level On th...

Page 42: ...ubsequent parameter Value to Set the Auto Mode Send 0 Send 1 Figure 27 Individual Buttons Climate Fan Dedicated Object for Auto Mode However two alternative and mutually exclusive methods are possible...

Page 43: ...splay where to show the indicator of this control i e the current fan speed The selected box must be configured with the same data type see section 2 3 for details Note this parameter is only availabl...

Page 44: ...in ETS by means of the proper checkbox which permits setting which of all the five extended modes will be included into the sequential scrolling implemented by the buttons Figure 29 Individual Buttons...

Page 45: ...de type LED Illumination Control Regular Dedicated Object Climate Special Mode This control is exactly the same as Climate Mode in its Extended version but with the modes Auto Comfort Standby Economy...

Page 46: ...55 Display http www zennio com Technical Support http support zennio com 46 State Make up Request Do not Disturb sets the desire function LED Illumination Control Regular State Dependant Dedicated Ob...

Page 47: ...g presses Moreover it is possible in parameters to make the state dependent and state dependent both LEDs LED illumination modes see ANNEX I LED Illumination Modes depend on either one object or the o...

Page 48: ...dependent both LEDs LED illumination modes are not available for this function See ANNEX I LED Illumination Modes for details Scaling Counter Float the touches over the buttons will trigger the sendin...

Page 49: ...dated after sending control orders that is after pressing the buttons being even possible to receive values from the bus for example from the corresponding setpoint status object from the external the...

Page 50: ...communication objects as X depends on the button pair LED Illumination Control sets the behaviour of the LEDs on the buttons Depending on the type of control selected for each buttons pair the option...

Page 51: ...h Figure 34 Pair Buttons Switch Action Left 0 Right 1 Right 0 Left 1 assigns each of the two buttons the value to be sent through Btn PX Switch Note this parameter will remain hidden unless having sel...

Page 52: ...alue to be sent through the object Btn PX Two Objects Long press when long pressing each of the two buttons Long Press Threshold Time 4 6 50 ds sets the minimum time the user should hold the button in...

Page 53: ...Decrease sets which of the two buttons will send the turn on orders and which the turn off orders Note this parameter will remain hidden unless having selected Every button pair is configured separate...

Page 54: ...ld the device will send the KNX bus an order to start moving the shutter upwards or downwards depending on the button Once the button is released it will send an order to stop the shutter Action Left...

Page 55: ...ee section 2 2 1 Minimum Value sets which value from the available range will be the minimum value permitted by the control after a number of presses on the decrease button Maximum Value sets which va...

Page 56: ...ize Sign Minimum Value Maximum Value Increment short press Increment long press Related Object Counter 1 Byte Signed 128 127 128 127 128 1 127 128 10 127 Btn PX Counter 1 Byte Signed Unsigned 0 255 0...

Page 57: ...egular Dedicated Object Climate Temperature Setpoint Figure 40 Pair Buttons Climate Temperature setpoint Action Left Decrease Right Increase Right Increase Left Decrease sets which of the two buttons...

Page 58: ...alue on every long press over the increase or decrease buttons respectively Note Long and short increments are applied in C regardless of the scale used Link the control with a box in the display sets...

Page 59: ...ch of the buttons to use to send an order to decrease and which to increase Note this parameter will remain hidden unless having selected Every button pair is configured separately in Action of the pa...

Page 60: ...Climate Mode Extended Figure 42 Pair Buttons Climate Mode Heat Cool Figure 43 Pair Buttons Climate Mode Extended Link the control with a box in the display sets the area of the display where to show...

Page 61: ...io com 61 Climate Mode Special This control is exactly the same as special mode control in individual buttons see sections 2 2 3 The climate mode will be controlled through the object Btn Px Climate S...

Page 62: ...icons Two different font sizes for the alphanumeric characters are available Small and Big only available for the numeric characters in the horizontal double boxes and screensaver On the other hand th...

Page 63: ...nfigured as an individual box Zone 2 setpoint box displayed centered on the display Zone 3 equivalent to Zone 1 Figure 46 Display Thermostat Page There are up to four representation modes configurable...

Page 64: ...PARAMETERISATION An independent tab for the parameterisation of the Display is shown in ETS by default While all the zones remain disabled it will only contain a sub tab named Configuration This displ...

Page 65: ...brings a new tab to the tree on the left named Box X where X depends on the display zone See section 2 2 3 Note this option will be available in all boxes except box 2 in Thermostat Page Pair Selecti...

Page 66: ...ting Every indicator is configured separately there will be a specific parameter for every box to select the desired indicator representation 2 3 2 DISABLED While a display zone remains disabled it do...

Page 67: ...ponding communication object Climate Temperature represents temperature values as received through the related communication object Values in the range 99 199 C and in the range 142 390 F are availabl...

Page 68: ...ones Climate On Off Mode Status Climate status indicator with three one bit objects associated On Off Mode and Status The icon represented depends on the value of these three objects Climate Mode Spec...

Page 69: ...option is only available for the following icon type indicators Icon Climate Mode Climate Fan Climate Special Mode Object to show hide indicator enabled disabled enables or disables a one bit object...

Page 70: ...or Icon Enumeration Enums 1 6 sets the number of states of the enumerated list Value 0 255 sets the numerical value assigned to the state Icon sets the icon to be displayed when the above value is rec...

Page 71: ...Counter 4 Byte Unsigned Scaling 1 Byte Btn BX Number Scaling Float 2 Byte Btn BX Number Float 2 Byte Table 8 Number Indicator Communiation objects Text Figure 53 Display indicator Text 1 bit Type 1 B...

Page 72: ...the numerical value assigned to the state Text sets the text to be displayed when the above value is received Text from object Figure 55 Display indicator Text from object The text to be shown is to b...

Page 73: ...or Cool will depend on the value of the Disp BX Climate Mode one bit object Figure 57 Display indicator Climate Mode Heat Cool Extended the icon represented will depend on the value of the Disp BX Cli...

Page 74: ...e Fan The value should be updated through the Disp BX Fan one byte communication object Off Auto 0 enabled disabled defines whether the Off Auto level is required to be represented or not If enabled t...

Page 75: ...that the climate system is on but stopped The icon represented will depend on the mode selected through Disp BX Climate On Off Mode 1 Heat or 0 Cool The representation type will be Permanent If Disp...

Page 76: ...lowing parameters will appear Text for each value sets the text to be displayed for each value 2 3 4 DOUBLE The display can be divided into up to 2 double boxes Double boxes can be assigned exactly th...

Page 77: ...of each indicator is exactly the same as for Individual boxes See section 2 3 3 for details 2 3 5 SETPOINT Thermostat type display will have central box always enabled for showing the setpoint tempera...

Page 78: ...number of waves to reflect the current speed level minimum average or maximum If AUTO mode is allowed there will be a binary object to indicate its mode The polarity of this object will be set by para...

Page 79: ...ble If this option is enabled the object Disp Bx Fan Auto On Off which will trigger the auto mode when it receives the corresponding value set in Value to activate Auto Mode Receive 1 to Set Auto Mode...

Page 80: ...motion detector model from Zennio Important older models of the Zennio motion detector e g ZN1IO DETEC and ZN1IO DETEC N will not work properly with Flat 55 Display 2 4 1 BINARY INPUT Please refer to...

Page 81: ...nnio website www zennio com for detailed information about the functionality and the configuration of the related parameters Notes This device does not include luminosity measurement capabilities Ther...

Page 82: ...lemented by the button The exact correspondence between the different values of the object and the different states of the LED may be slightly different from one type of control to another and is deta...

Page 83: ...d Regular State dep State dep both LEDs Dedicated object INDIVIDUAL LED Indicator Switch Hold Release Two Objects Scene Constants Dimmer Shutter Enumeration Fan Mode Special Mode Room State PAIR Switc...

Page 84: ...t being then necessary to configure the same option multiple times In case of opting for a general configuration the options are Regular State Dependent where available Functions where state dependent...

Page 85: ...ER SELECTION All characters supported by the device according to the alphabet type are shown below Latin 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ a b c d e f g h i j k...

Page 86: ...Bit 0 Under Threshold 1 Over Threshold 10 1 Byte O C R DPT_Scaling 0 100 General Luminosity Percentage 0 100 11 2 Bytes O C R DPT_Value_Lux 671088 64 670760 96 General Luminosity Lux 0 Lux 670760 Lux...

Page 87: ...Bit Generic Control 1 Bit I C T W U DPT_Switch 0 1 Btn Ix Two Objects Short Press 0 1 1 Bit Generic Control 1 Bit I C T W DPT_Step 0 1 Btn Ix Fan Control Type 1 Bit 0 Decrease 1 Increase 1 Bit I C T...

Page 88: ...on Short Press 1 Bit I C T W U DPT_Switch 0 1 Btn Ix Fan Control Auto Mode Switch Auto Mode on Long Press 1 Bit I C T W DPT_Switch 0 1 Btn Py Two Objects Long press Left 0 Right 1 1 Bit I C T W DPT_Sw...

Page 89: ...r 4 Bit I C T W DPT_Control_Dimming 0x0 Stop 0x1 Dec by 100 0x7 Dec by 1 0x8 Stop 0xD Inc by 100 0xF Inc by 1 Btn Py Light Dimming Long press Left Brighter Right Darker 4 Bit I C T W DPT_Control_Dimmi...

Page 90: ...5 Btn Ix Fan Control Type Enumeration 1 2 1 Byte I C T W DPT_Value_1_Ucount 0 255 Btn Ix Fan Control Type Enumeration 1 2 3 1 Byte I C T W DPT_Value_1_Ucount 0 255 Btn Ix Fan Control Type Enumeration...

Page 91: ...Mode Control Auto Comfort Standby Economy Building Protection 1 Byte I O C T R W DPT_HVACContrMode 0 Auto 1 Heat 3 Cool 9 Fan 14 Dry Btn Ix Climate Mode Extended Rotating change of selected modes on s...

Page 92: ...ype Enumeration 0 1 2 3 4 5 1 Byte I C T W DPT_Value_1_Ucount 0 255 Btn Py Fan Control Type Enumeration 0 1 2 3 4 1 Byte I C T W DPT_Value_1_Ucount 0 255 Btn Py Fan Control Type Enumeration 0 1 2 3 1...

Page 93: ...00 1 Byte I C T W DPT_Scaling 0 100 Btn Pz Fan Control Type Scaling 100 1 Byte I C T W DPT_Scaling 0 100 Btn Pz Fan Control Type Scaling Auto 50 100 1 Byte I C T W DPT_Scaling 0 100 Btn Pz Fan Control...

Page 94: ...9 Fan 14 Dry Btn Pz Climate Mode Extended Rotating change of selected modes on short press 1 Byte I C T W U DPT_HVACMode 1 Comfort 2 Standby 3 Economy 4 Building Protection Btn Pz Climate Special Mode...

Page 95: ...Increase Up Decrease 2 Bytes I C T W DPT_Value_Temp 273 00 670760 00 Btn Pz Climate Temperature Setpoint Down Decrease Up Increase 2 Bytes I C T W DPT_Value_Temp 273 00 670760 00 Btn Pz Climate Temper...

Page 96: ...n Off 0 Off hide indicator 1 On show mode or status 66 74 82 90 1 Bit I C T W U DPT_Switch 0 1 Disp Bx Climate On Off Status 0 Halted 1 Running Status icon is shown when On Off 1 and Status 1 1 Bit I...

Page 97: ...igned Object Numeric Value is Shown 1 Byte I C T W U DPT_Scaling 0 100 Disp Py Number Scaling Object Numeric Value is Shown 1 Byte I C T W U DPT_HVACMode 1 Comfort 2 Standby 3 Economy 4 Building Prote...

Page 98: ...alue is Shown 2 Bytes I C T W U DPT_Value_2_Count 32768 32767 Disp Bx Number Counter 2 Bytes Signed Object Numeric Value is Shown 2 Bytes I C T W U 9 xxx 671088 64 670760 96 Disp Bx Number Float 2 Byt...

Page 99: ...sp Bx Fan Auto On Off Auto Mode With 0 1 Bit I C T W U DPT_Switch 0 1 Disp Bx Fan Auto On Off Auto Mode With 1 75 1 Byte I C T W U DPT_Scaling 0 100 Disp Bx Fan 2 levels Off 0 Min 1 50 Max 51 100 1 By...

Page 100: ...00 0x7 Dec by 1 0x8 Stop 0xD Inc by 100 0xF Inc by 1 Ix Short Press Darker Decrease Brightness 4 Bit C T DPT_Control_Dimming 0x0 Stop 0x1 Dec by 100 0x7 Dec by 1 0x8 Stop 0xD Inc by 100 0xF Inc by 1 I...

Page 101: ..._UpDown 0 1 Ix Long Press Move Up Shutter Sending of 0 Up 1 Bit C T DPT_UpDown 0 1 Ix Long Press Move Down Shutter Sending of 1 Down 1 Bit C T DPT_UpDown 0 1 Ix Long Press Move Up Down Shutter Switchi...

Page 102: ...ss Save Scene Sending of 128 191 1 Byte C T DPT_SceneControl 0 63 128 191 Ix Double Press Run Scene Sending of 0 63 104 110 1 Bit C T DPT_Trigger 0 1 Ix Long Press Release Stop Shutter Release Stop Sh...

Page 103: ...DPT_Ack 0 1 Ix External Motion Detection 0 Nothing 1 Motion detected by an external sensor 136 141 146 165 170 175 1 Byte O C T R DPT_Scaling 0 100 Ix Cx Detection State Scaling 0 100 137 142 147 166...

Page 104: ...point Thermostat Setpoint Input 2 Bytes I C W DPT_Value_Temp 273 00 670760 00 T1 Basic Setpoint Reference Setpoint 193 1 Bit I C W DPT_Step 0 1 T1 Setpoint Step 0 Decrease Setpoint 1 Increase Setpoint...

Page 105: ...Control Variable Cool 2 Point Control 1 Bit O C T R DPT_Switch 0 1 T1 Sx Control Variable Cool PI Control PWM 210 216 1 Bit O C T R DPT_Switch 0 1 T1 Sx Control Variable Heat 2 Point Control 1 Bit O...

Page 106: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: