Nominal flow q
p
m³/h
0.6
1.5
2.5
Maximum flow q
s
m³/h
1.2
3.0
5.0
Minimum flow q
i
CMF
l/h
24
30 / 60
50 / 100
Minimum flow q
i
ASF
l/h
24
60
100
Starting flow horizontally ca.
l/h
5
5
7
Temperature range CMF
°C
10 ≤ Ө q ≤ 90
Temperature range ASF
°C
15 ≤ Ө q ≤ 90
Minimum pressure
(to avoid cavitation)
bar
0.3
Nominal pressure /
peak pressure
PS/PN
16/16
IP protection class
54 ( 65 for heating and cooling energy
metering)
Installation position
horizontal, horizontal tipped through
90°, vertical (for stand- or downpipe
installation)
Heat carrier
Water
Temperature range heat
calculator
°C
0...105
Temperature difference range
K
3...80
Ambient class according to
EN 1434
C
Storage temperature
°C
-20...+65
Interfaces
Standard
optical interface (ZVEI, IrDA)
optional
3 pulse inputs/outputs, M-Bus,
wireless M-Bus, LoRaWAN
Ambient conditions /
climatic influencing
(valid for complete compact
meter)
- climatic
Highest permissible ambient tempera-
ture 55 °C
Lowest permissible ambient tempera-
ture 5 °C
- mechanical
class
M1
- electro-
magnetic
class
E1
Scope of supply
■
zelsius® C5 measuring capsule with calculator
■
1x seal (according to the model)
■
Seal material
■
Wall bracket with fastening materials (only for version with a detachable
calculator)
■
Installation and operating manual, declaration of conformity
Technical data
Summary of Contents for zelsius C5-ASF