background image

English

Installation manual

 

TheWSserieshasbeenapprovedwithaflowsensitivityclassU0/D0.
However,toachievethebestmeasurementresults,werecommend
observingnationalregulationsandrecognisedrulesoftechnology.

 

ForWSseriesisrecommendedastraightinletsectionofatleast5xDN.

 

Ideally,atleast2xDNshouldbeavailableastheoutletsection.

 

Beforeinstallingthemeter,thepipingmustbethoroughlyflushedout.

 

Thepipediametershouldnotbereduced,directlyinfrontandbehind

the meter.

 

Flangegasketsmustnotextendintothepipe.

 

Itmustbeensuredthattheflowdirectionofthemetermatchesthatof

the pipe.

 

Valvesorotherflowregulatorsshouldbeinstalled,wherepossible,
behindthemeter.

 

Themetershouldbeinstalled,wherepossible,atthehighestpointof
thepipeinstallationsothatairbubblesarenotabletoforminthemeter
andthepipeisalwayscompletelyfilled.

 

Ifnecessary,themetershouldbeprotectedbyacorrespondingfilter,
sothatnoforeignparticles,suchasstonesorsand,areflushedintothe
measuringinstrumentandcausedamage.

 

Themetermustbeprotectedagainstpressuresurgesinthepipe

 

network.

 

Themaximumwatertemperaturemustnotexceedthepermissible50
°Cforcoldwater.

 

Inordertopreventdamagetothemeasuringinsertcausedbypressure
surges,thepipemustbeslowlyfilledfollowinginstallation.

 

Itmustbeensuredthatthemeterisinstalledinade-energisedstate
inthepipe.Inthecaseofaninstallationthatisnotde-energised,the
housingofthemeasuringinstrumentcanbedamagedandwatermay
escape.

 

Thepipelinepressuremustnotexceedthemaximumworkingpressure
ofthemeter,asthiscanleadtoleaksanddamageofthemeter.

 

Topreventthedisassemblyofthemeterwerecommendtosecurethe
connectioninterfacewithasafetydevice(adhesivelabel,seal,etc.).

 

AllserieshasbeenapprovedwithaflowsensitivityclassU0/D0(noinlet
outletsectionrequired).

 

Allseriesarenotapprovedforbackflowmeasuring.

Installation instructions for the replacement of the metrological unit

 

Theexchangeofexchangeablemetrologicalunits(measuringinsert
shouldonlybeperformedbytrainedspecialiststaff.

 

Beforechangingthemeasuringinsert,thepipemustberinsedcarefully
shutoffthepressuresideandemptythepipe.

 

Thecomplianceoftheinterfacesmarkingonthemeasuringandatthe
specifiedinterface(body)(WS1)mustbechecked.

 

Afterdisassemblyofthemeasuringinsertoldgaskets/sealsmustbere

-

moved.Thesealingsurfacesmustbecleanedandcheckedfordamage.

 

Itisimportanttoensurethattheinletareaisfreeofdeposit,beforea
newmetrologicalunitisinstalled,becauseasthesecanleadtodevia

-

tions of the measurement result.

 

Useonlythegenuineseals,whicharedeliveredtogetherwiththe
measuringinsert.Thesehavetobecheckedpriortoinstallationfor
damageandfit.

 

Whenusinglubricants/assemblypastese.g.fortheseals,itmustbe
ensuredthatthesearesuitableforcontactwithdrinkingwater.

 

Tightenthescrewsofthemeasuringunitevenlycrosswise(M12:DN50–
DN100=60Nm;M20:DN150–DN200=100Nm).

 

Topreventthedisassemblyofthereplacablemeasuringinsert,itmust
beconnectedwiththeconnectioninterface(housing)byasealingwire.

Thedeclarationofconformityisincludedinthedelivery.Thelatestinforma

-

tiononthisproductcanbecalledupfrom

www.zenner.com

Remark

Thisinstallationmanualisintendedforqualifiedspecialistsonly.Basic
installationstepsarethereforenotdescribed.

Permissible installation positions

TheWSseriesisintendedforinstallationinthehorizontalpositiononly.

Installation instructions

WSD/WSDE

Reviews: