4

 

 

 

 

 

2.12.  Usingslightpressurebrieflyturninganti-clockwise,findthestartofthethread

and then tighten the threaded ring in a clockwise direction with a torque of 20 

Nm. The counter also rotates.

2.13.  Carefullysetlineunderpressurebyopeningthemainstopvalve.Carefully

check seal and function (forward running). If the meter is running backwards the 

FMTwasnotinstalledinaccordancewiththeflowdirection.Thendismantlethe

capsule,insertthereverseflowpreventerintotheotheropening,re-assemble

the capsule rotated by 180°.

2.14.   Turn the counter to the reading position. Slide the cap for sealing over the coun-

ter. Insert the plastic seals (anti-dismantling protection) with the barbed hook 

inwards into the sealing hole of the cap and snap into place (Fig. 8).

2.15.  Inthecaseofaflush-mountedinstallation,taketherosetteoutofthepackaging

and if required due to the large insertion depth, insert one to three extension 

connectors. A special rosette must be ordered for installation depths below 25 

mm. Press the rosette (possibly with extension sleeves) onto the counter cap on 

the wall until the end stop (Fig. 9). 

2.16.   For wet room installations with an extension connection, a rosette disk can also 

be inserted and this must be ordered separately.

3.  Meter exchange

3.1.   Block and empty the line by closing the mains stop valve.

3.2.  Inthecaseofflush-mountedinstallations,removetherosette(possiblywiththe

extension connectors).

3.3.   Open the two plastic seals in the cap of the meter by turning a small screwdriver 

and remove the cap.

3.4.   Push the assembly side of the installation wrench with the linear grooves over 

the pull-out cams to the meter and turn anti-clockwise, until the pins of the 

installation wrench snap in place in the threaded ring. Unscrew the threaded 

ring in an anti-clockwise motion. The counter also rotates.

3.5.   Remove the installation wrench and slide over the pull-out cams with the pull-

ing side and rotate. Then use the installation wrench to remove the meter from 

the housing.

3.6.  Cleananydirtfromthehousing,inparticularthesealingsurfaceoftheO-ring.

3.7.  Assemblethenewmeasuringinsert,asdescribedinNo.2.6to2.16.Carefully

check seal and function.

4.  Minomess® micro installation wrench

The pulling side has two angled longitudinal slots to cover the pull-out cams of the 

counter. The assembly side of the wrench for assembling the threaded ring has four 

pinsandfourlineargroovesoffsetby45°(Fig.10).

5.  User safeguard

A user safeguard (adhesive label, seal etc.) must be used to detect whether the 

measuring capsule has been removed from the connection interface or to prevent an 

unauthorised removal.

The declaration of conformity is included in the delivery. The declaration of conformity 

and the latest information on this product can be called up from www.zenner.com.

Fig. 6

Fig. 7

Fig. 8

Fig. 9

ZENNER International GmbH & Co. KG

Römerstadt 6 | 66121 Saarbrücken | Germany

E-Mail [email protected]
Internet www.zenner.com

Phone 

+49 681 99 676-30

Telefax 

+49 681 99 676-3100

Su

bj

ec

tt

o

m

od

ifi

ca

ti

on

s

an

d

er

ro

rs

e

xc

ep

te

d.

W

e

ac

ce

pt

n

o

lia

bi

lit

y

fo

ra

ny

e

rr

or

s

or

m

is

pr

in

ts

.

Fig. 10

Summary of Contents for Minomess micro

Page 1: ...rungen am UPT Anschluss anliegen und mit dem beigelegten Gummiring fixieren siehe Abb 2 2 Erstmontage des Messeinsatzes 2 1 Die Leitung sorgfältig durchspülen Anschließend durch Zudrehen des Woh nungs oder Strangventils absperren und entleeren 2 2 Bei Unterputzinstallation Kunststoff Einputzkappe abziehen bzw Einputzscha len mit scharfem Messer wandbündig abschneiden 2 3 Mit dem Montageschlüssel d...

Page 2: ...n zusätzlich eine Rosettenscheibe eingesetzt werden die gesondert zu bestellen ist 3 Zählertausch 3 1 Leitung durch Zudrehen des Wohnung oder Strangventils absperren und ent leeren 3 2 Bei Unterputzinstallation Rosette ggf mit Verlängerungshülsen abziehen 3 3 Die beiden Kunststoffplomben in der Kappe des Zählers mit einem kleinen Schraubendreher durch Verdrehen öffnen und Kappe abnehmen 3 4 Die Mo...

Page 3: ...onnection and fix with the rubber ring provided see Fig 2 2 Initial assembly of the measuring insert 2 1 Thoroughly rinsing the pipeline Then block and empty the line by closing the mains stop valve 2 2 In the case of the flush mounted installation remove the plastic flush mounted cap or trim the flush mounted shell flush with the wall with a sharp knife 2 3 Use the installation wrench unscrew and...

Page 4: ...wo plastic seals in the cap of the meter by turning a small screwdriver and remove the cap 3 4 Push the assembly side of the installation wrench with the linear grooves over the pull out cams to the meter and turn anti clockwise until the pins of the installation wrench snap in place in the threaded ring Unscrew the threaded ring in an anti clockwise motion The counter also rotates 3 5 Remove the ...

Reviews: