background image

Page 4

Read These Warnings First

•  Ensure that the location and fasteners will support the weight of the system when in-

stalled and full of water.

•  Ensure all tubing and fi ttings are secure and free of leaks.

•  Do not install using rigid piping.  System intended for use with plastic water lines (such as 

PEX tubing, PE tubing, PP tubing).

•  The disposable fi lter cartridge MUST be replaced every 12 months, at the rated capacity or 

sooner if a noticeable reduction in fl ow rate occurs.

How to Replace the External Filter Cartridge

This instruction is for the replacement of the filter in product where the filter is mounted 
externally. In preparation for your filter activation/flushing, ensure you have a 10 litre 
container available. 

Some water may drip from the filter head (socket) during replacement. Keep a towel handy to 
dry up any drips.

To Change the Filter:

1.  Shut off the main water supply isolation valve at the wall.

2.  Grasp filter cartridge and twist right to left one quarter turn until it stops. 

3.  Ease cartridge downwards to detach it from the filter head (socket). 

 

Caution:  

A small amount of water will drip as the cartridge is removed. 

4.  Do not tilt the cartridge as water may spill from it.

5.  Unpack the replacement cartridge, remove the sanitary cap and write today’s date where 

shown on the label. 

6.  Avoid touching the filter “O” rings and filter opening as this may cause bacterial 

contamination of the cartridge.

7.  Align the filter cartridge marker IN/OUT with the marker on the left side of the filter head.

8.  Slide the cartridge upward into the head and rotate from left to right until the LOCK 

marker aligns with the filter head marker. 

9.  Re-open the main water supply isolation valve at the wall.

10. To activate the cartridge, if connected to a filter tap, run water by opening the tap until 

approximately 10 litres of water has passed through the filter. (for other combined 
products see warning below)

11. Wipe up any spills and dispose of the spent filter cartridge and packaging thoughtfully.

Warning:

 

If the filter is external to a boiling water, chilled water or combined boiling and 

chilled water dispensing product, the hose that enters the dispensing product should be 
disconnected from the product and the filter activation/flush needs to be directed through this 
hose into a bucket to avoid flushed particles from entering into the storage tanks.  

1

2

REMOVE FILTER

INSERT FILTER

FILTER CARTRIDGE REPLACEMENT

How to Replace the Internal Filter Cartridge

2

1

This instruction is for the replacement of the filter in the Zenith       HydroTap product where 
the filter is mounted internally. In preparation for your filter flushing, ensure you have a 10 litre 
container available. 

Some water may drip from the filter head (socket) during replacement. Keep a towel handy to 
dry up any drips.

Summary of Contents for GlobalPlus 800955NZ

Page 1: ...Zenith GlobalPlus Water Filters Installation Instructions 800955NZ Sept 2014 v1 00 Affix Model Number Label Here 800955NZ GP...

Page 2: ...This page intentionally left blank...

Page 3: ...ition to mount the system bracket CAUTION To reduce the risk associated with property damage due to water leakage Read and follow Use Instructions before installation and use of this system Installati...

Page 4: ...abel 6 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 7 Align the filter cartridge marker IN OUT with the marker on the left side of th...

Page 5: ...on with the front label facing forward 10 Locate the filter flush hose situated behind the filter cartridge and direct the hose into a container ready for flushing Open the filter flush stop cock On t...

Page 6: ...r is fitted to an appliance please refer to the appliance owner s guide for more product specific information and advice on how to avoid contamination from improper handling and installation Warranty...

Page 7: ...ents NSF Test Report Chlorine Taste and Odor 2 0 mg L 2 0 mg L 10 97 3 0 05 mg L N A 5 0 mg L 50 J 00109688 Cyst 140 000 cysts L Minimum 50 000 cysts L 99 99 3 cyst L N A 1 cyst 100 L 99 95 J 00109693...

Page 8: ...L 2 0 mg L 10 97 3 0 05 mg L N A 5 0 mg L 50 J 00109688 Benzene 0 015 mg L 0 015 MG L L 10 95 3 0 0007 mg L 0 005 mg L 0 01 mg L N A J 00113270 Cyst 140 000 cysts L Minimum 50 000 cysts L 99 99 3 cys...

Page 9: ...tandard 3497 Max Permissible Prod uct Water Concentration NSF Reduction Require ments NSF Test Report Chlorine Taste and Odor 2 0 mg L 2 0 mg L 10 91 4 0 17 mg L N A 5 0 mg L 50 J 00109690 Cyst 98 750...

Page 10: ...d AS NZS Standard 3497 Max Permissible Prod uct Water Concentration NSF Reduction Require ments NSF Test Report Chlorine Taste and Odor 2 0 mg L 2 0 mg L 10 97 3 0 05 mg L N A 5 0 mg L 50 J 00109688 B...

Page 11: ...NOTES Page 11...

Page 12: ...klet have been modified and may not be true representations of the finished Goods The standard cup referred to in this publication is 167 ml 6 fl oz The standard glass is 200 ml 7 fl oz The terms Zeni...

Reviews: