09
806143NZ v1.06 07.19 CW ChillTap UCCT
Installation instructions
Hose connections
Note: To avoid water leaks, be careful not to damage the
tubes. The tube must not be kinked around a bend, as the
tube may contain water under pressure. If shortening the
hoses, ensure ends are cut clean and square.
1. Remove plugs from the outlet fittings on the top of
the command centre by depressing the collet and
simultaneously pulling out the plug.
2. Measure and trim the three 1/4” coloured hoses from the
carafe tap to the outlet fittings on the top of the command
centre. See Fig.6 and Fig.7.
3. Before making the connections, insulate the hoses with the
loose length of foam insulation. Trim the insulation to about
5-10mm shorter than the tube.
4. For correct hose connection, refer to Fig.6 for ChillTap
Standard and ChillTap Heavy Duty, and Fig.7 for ChillTap
Extra. Push each hose into the quick-release connector as
far as it will go (approx. 15 mm) to ensure a tight connection.
ChillTap Extra
BLUE
WHITE RED
ChillTap Extra
WHITE: Ambient
BLUE: Chilled
RED: Vent
Fig.7
ChillTap Standard / Heavy Duty
WHITE: Chilled
BLUE: Tee piece, side
RED: Tee piece, top
BLUE
WHITE
RED
Tee piece
ChillTap Standard
ChillTap Heavy Duty
Fig.6
Commissioning
Turn on the water supply to the unit, then rotate and hold the
chilled water or ambient water lever (ChillTap Extra). First air,
then water will flow from the tap. Allow the water to continue
to flow for about 10 litres, which is required to activate the filter.
Once this has been done release the lever to turn off the water.
The lever will spring back to the upright position.
Connect the unit to the mains power supply and turn ON.
Switch ON the switch at the side of the command centre.
The compressor and fan will start, and will continue to run until
temperature is reached.