Operation & Maintenance

Operation

To dispense chilled, filtered water, rotate the lever on the right 
hand side of the carafe tap to a horizontal position. The lever will 
spring back when released.

ChillTap Extra: 

Chilled still filtered water is dispensed using the 

lever on the right hand side of the carafe tap (blue marking).
Ambient filtered water is dispensed using the lever on the left hand 
side of the carafe tap (white marking). 
The levers will spring back to the upright position and water flow 
will stop, when released.

Chilled filtered
water (blue)

(ChillTap Extra)
Ambient water
(white)

ROTATE

Water filter

For safe operation, the filter cartridge should be replaced every 
6-12 months, or earlier if you notice a persistent reduction in water 
pressure from the appliance or an unpleasant taste or odour in the 
water. To replace the water filter cartridge:
1.  Turn off the water and power supply to the unit.
2.  Turn on the chilled water lever (blue marking), to release the 

water pressure in the unit. Once water has stopped running 
from the tap, turn off the lever.

3.  Turn the filter clockwise and gently pull the cartridge down. 

The cartridge should release from the filter head. Dispose of 
the filter cartridge responsibly. Clean any water that has pooled 
below the filter head.

4.  Fit a new filter by turning filter anti-clockwise and gently 

pushing up. The filter will click or lock into place.

5.  Turn on the water supply to the unit. 
6.  Turn on the chilled water tap and dispense at least 7.5 litres.
7.  Turn off the chilled water tap.
8.  Turn on the power supply to the unit.

1. ROTATE

2. PULL DOWN

1. INSERT

2. ROTATE

REMOVE FILTER

INSERT FILTER

Warning: 

Not changing filtration cartridges when required 

may cause the water to become biologically unsafe. 
If the Zenith ChillTap is switched off for a long period of time 
(e.g. more than 2-3 days), run water through the chilled 

water outlet for at least 5 minutes before consumption.
Use only a Zenith filter to match that used with this ChillTap (if 
fitted). Replacement filter cartridges can be obtained through 
plumbing suppliers or directly from Zenith.

Air inlet screen

The Zenith ChillTap air inlet screen is located on the side of 
the under sink unit. The screen needs to be inspected at least 
quarterly, cleaned and replaced if damaged.
Remove the screen for cleaning by sliding it forward. Rinse off any 
particles with tap water, then gently dry with a cloth or towel. Slide 
the screen back into place.

Note:

 For best performance the unit should only be operated with 

a clean air inlet screen, correctly fitted in place. Maintain at least 
a 50 mm air gap in front of the screen at all times. Take care not 
to allow cloths or other soft materials to accidentally block the air 
inlet.

Slide to remove

Summary of Contents for ChillTap 140 glass

Page 1: ...1 806143NZv1 0607 19CWChillTapUCCT Installation instructions user manual Zenith ChillTap Filtered chilled water on tap AFFIXPRODUCTLABELHERE ...

Page 2: ...hnical specification 04 Before installation 04 Installation instructions 05 Tap installation 05 Ventilation 06 Command centre installation 08 Commissioning 09 Operation Maintenance 10 Operation 10 Water filter 10 Air inlet screen 10 Troubleshooting 11 Cleaning 11 End of life disposal 11 ...

Page 3: ...s designed for indoor use and must not be installed outdoors or exposed to the elements of nature 9 This unit must not be positioned in an area that may be cleaned by a water jet 10 This unit must not be cleaned by a water jet 11 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they ...

Page 4: ...tra filtration will be required Check the appliance rating plate and ensure correct power is available for the appliance Check the underbench cupboard supporting the appliance is adequate for the total weight and size of the appliance Power supply 220 240V AC 50Hz for connection via a 10 amp electrical power outlet Operating temperatures 5ºC 35ºC External water pressure 150kPa 700kPa 1 5 bar 7 bar...

Page 5: ...e a neat hole without burrs Remove the large nut from the base of the tap leaving the rubber sealing ring O ring in place Fit the tap and O ring to the sink top oriented so the operating lever is easily accessible From under the sink slide the nut over the tubes Tighten the nut to secure the tap firmly into place ChillTap Extra Fig 2 Use a 35mm sheet metal punch or hole saw to create a neat hole w...

Page 6: ...ChillTap must be installed in the cupboard The vent kit ensures heat dissipation through forced convection Air is drawn in through the front vent and expelled from the command centre Residential models are supplied with a 2 piece vent kit See Fig 4 cut out B The second grille may be installed in the cupboard door side wall if required Commercial models are supplied with a 4 piece vent kit See Fig ...

Page 7: ...igsaw and Keyhole or Wall Board saw 60 00 B C 12 00 45 00 284 Additional ventilation The following instructions are critical if the vent kit as supplied cannot be fitted If the vent kit cannot be used or for high use applications where the cupboard space temperature is 35 C or higher an optional Vent Tray Kit or Exhaust Fan kit may be fitted Contact your local service centre for more information V...

Page 8: ...pplied in the water supply line before the connection to the product Connect the braided hose to the isolation valve installed in the mains water supply line For best results the recommended minimum static pressure is 250 kPa 2 5 bar Connect the braided hose from the isolation valve to the top of the command centre marked MAINS IN see Fig 5 On Off Switch If caps are removed to allow lifting handle...

Page 9: ...rd and ChillTap Heavy Duty and Fig 7 for ChillTap Extra Push each hose into the quick release connector as far as it will go approx 15 mm to ensure a tight connection ChillTap Extra BLUE WHITE RED ChillTap Extra WHITE Ambient BLUE Chilled RED Vent Fig 7 ChillTap Standard Heavy Duty WHITE Chilled BLUE Tee piece side RED Tee piece top BLUE WHITE RED Tee piece ChillTap Standard ChillTap Heavy Duty Fi...

Page 10: ...d below the filter head 4 Fit a new filter by turning filter anti clockwise and gently pushing up The filter will click or lock into place 5 Turn on the water supply to the unit 6 Turn on the chilled water tap and dispense at least 7 5 litres 7 Turn off the chilled water tap 8 Turn on the power supply to the unit 1 ROTATE 2 PULL DOWN 1 INSERT 2 ROTATE REMOVE FILTER INSERT FILTER Warning Not changi...

Page 11: ...ith Service Provider Internal water leak Contact local Zenith Service Provider Water not chilled No power Restore power to the unit Thermostat faulty or out of calibration Contact local Zenith Service Provider Insufficient cooling air flow through the refrigeration system Check and clean air inlet screen Refrigeration failure Contact local Zenith Service Provider Rated chilled water capacity has b...

Page 12: ...8 8612 Free Call 0800 558 055 Products described in this publication are manufactured under one or more patents and further patent applications are pending As Zenith s policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods 2019 Zenith Heaters Ltd ...

Reviews: