Autoboil - Installation & Operating Instructions - 81355 - May 2012 v1.01 

Page 7 of 12 

Problem Solving

Operating procedures

Tap Operation

Autoboil is fitted with a two-way safety tap.

The tap assembly has two positions, one is the “cup fill” quick return mode. 
This operation is achieved by having the handle with the curved cam at the 
base of the tap handle facing you. When the handle is released this mode 
allows instant water cutoff.

The second mode is “pot fill”, to use this position rotate the handle 180º 
from the “cup fill” side so a flat face cam is showing at the handle base. This 
operation allows a vessel to be filled without holding your hand where it may 
be affected by steam. 

“Pot fill” position

“Cup fill” position

Symptom

Possible Cause

Solution

Fails to dispense water.

Water isolating valve turned off.

Blocked filter, blocked meter tube, 

blocked strainer, jammed ball valve 

assembly, airlock in transfer tube. 

Check water supply valve.

Contact The Zenith Heaters Limited 

service dept.

Water not boiling.

No power.

Faulty thermostat, faulty element,  

faulty cutout, faulty contactor.

Check power supply.

Contact The Zenith Heaters Limited 

service dept.

Runs out of boiling water and fails to 

refill.

Outlet tap drips.

Overflow from vent.

Excessive steam from vent.

Power “on” but no heat.

Overload repeatedly tripping with 

excessive steam.

Overload repeatedly tripping without 

excessive steam.

Internal adjustment.

Contact The Zenith Heaters Limited 

service dept.

Summary of Contents for 04652 Autoboil

Page 1: ...n Operating Instructions 81355 May 2012 v1 01 Page 1 of 12 Installation and Operating Instructions Autoboil Instant boiling water 11652 Autoboil 15 Litre White 12652 Autoboil 25 Litre White 04652 Auto...

Page 2: ...g 5 a Plumbing 5 b Venting 5 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Problem Solving 7 Operating Procedures 7 Wiring Diagram 8 Mounting Template 9 Thermostat Settings 10 Connecting J...

Page 3: ...osive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use do not turn off t...

Page 4: ...then insert the flow restrictor into the outlet pipe before securing tap assembly Step 1 Positioning Position the heater so the tap will drain onto the draining board or drip tray Position the base o...

Page 5: ...g Water pressure requirements Minimum 100 kPa Maximum 700 kPa Warning If pressure is likely to exceed 700 kPa a pressure limiting valve must be installed in the cold water supply line We recommend a v...

Page 6: ...tube using PTFE tape Screw the tap clockwise until the tap assembly touches the fascia without pressure Continue to turn the tap a further one full turn until the tap lever is upright Step 5 Commissi...

Page 7: ...out holding your hand where it may be affected by steam Pot fill position Cup fill position Symptom Possible Cause Solution Fails to dispense water Water isolating valve turned off Blocked filter bloc...

Page 8: ...amp is illuminated this indicates that the power is connected and turned on and that the heater is operating normally Cleaning Case Do not use strong corrosive spray or abrasive cleaners Clean the cas...

Page 9: ...rating Instructions 81355 May 2012 v1 01 Page 9 of 12 Mounting Template Wall template for 15 litre 25 litre 40 litre models 374 15L 25L 499 40L 295 15L 25L 420 40L 591 15L 25L 771 25L 831 40L 188 15L...

Page 10: ...2NZ Cistern Float S Nut Kit 10 90495NZ Banjo Screw Kit 11 90110NZ Fascia Light Kit 12 90501NZ Tap Top Kit 13 90499NZ Fascia Lens Kit 14 90494NZ Metering Tube Kit 2400 w 90527NZ Metering Tube Kit 3600...

Page 11: ...Autoboil Installation Operating Instructions 81355 May 2012 v1 01 Page 11 of 12 Exploded View...

Page 12: ...ng Warranty As Zenith Heaters Limited policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not b...

Reviews: