801910NZ - Sparkling HydroTap - Installation Instructions - Aug 2015 - V2.01
Page 41 of 44
Commissioning
Pull both levers
forward
Safety
sensor
7.5
-
Safety Sensor Calibration (Boiling models)
1.
Press the [MENU] button for main menu.
2.
Press the [Install] button.
3.
Press the [Booster] button.
4.
In the next screen, press YES to enable the Booster.
5.
Turn the Booster ON
6.
Water must be run through the Booster for a min of 30
seconds, before the heater will activate.
7.
Dispense boiling water for 30 secs and check the
Booster outlet hose is warm when the boiling water
tank is replenishing.
NOTE:
For any subsequent fi lter changes or any operational procedures, please refer to the HydroTap user
guide, located inside the fi lter housing access door.
To enabled when a Booster unit is installed.
1.
With the unit in Normal operating mode and with
the safety enabled
2.
Turn the power OFF
3.
Pull both tap levers to the forward position
4.
Turn ON the power
5.
The unit will calibrate the safety switch
6.
Return the levers to the neutral position.
7.
To check the calibration, dispense Boiling water,
in normal light conditions with the safety enabled.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration.
This can be achieved by closing any nearby curtains, blinds, or by shielding the HydroTap with a dark cloth.