background image

Configuration Manual

SIP Master Stations

A100K11211

TECHNICAL MANUAL

Summary of Contents for Vingtor Stentofon 1008015000

Page 1: ...Configuration Manual SIP Master Stations A100K11211 TECHNICAL MANUAL...

Page 2: ...Author Status 1 0 19 1 2012 HKL published 1 1 9 6 2017 HKL VS format SIP server Related Documentation For further information refer to the following documentation Doc no Documentation A100K10788 IP M...

Page 3: ...Program 20 3 2 Manual Software Upgrade 20 3 3 Automatic Software Upgrade 21 4 Station Board Connections 23 5 Station Indication LEDs 26 5 1 Station LED 26 5 2 Status LED 26 5 3 Power LED 26 5 4 LAN L...

Page 4: ...set The IP Desktop Master is a general purpose intercom station featuring a large high contrast display with backlight showing crystal clear information Ten direct access keys DAK provide single touch...

Page 5: ...to the user according to priority and time of arrival The user can select which call to answer by scrolling through the queue Four direct access keys DAK provide single touch access to stations group...

Page 6: ...tup menu 1 Press the Setup button on the left 2 Enter the password 1851 3 Press the Ok button Station mode If SIP settings is not listed as a main menu option select Station mode to set the station to...

Page 7: ...Display Station Figure 4 RJ45 Ports on IP Flush OR Master Stations The factory default IP address of the station is 169 254 1 100 In order for your PC to communicate with the station it is necessary t...

Page 8: ...button IP Settings DHCP Use this option if the SIP Station shall receive IP Settings from a DHCP server Static IP Use this option if the SIP Station shall use a static IP address Enter the IP address...

Page 9: ...is the tertiary backup domain Authentication User Name This is the authentication user name used to register the station to the SIP server This is required only if the SIP server requires authenticat...

Page 10: ...on event When enabled the station will activate the relay when receiving the specified DTMF character in the RTP stream Select from the dropdown menu Options are OFF 1 9 In call or Ringing The defaul...

Page 11: ...se reduction of 36 3 dB Microphone Sensitivity Select the sensitivity level in the range 0 to 7 from the dropdown menu The default setting is 5 Remote Controlled Volume Override Mode This acts as simp...

Page 12: ...ster stations have 10 Direct Access Keys and do not have the 3 Input Buttons described below Input Button 1 This is the SIP ID for the extension to be called when call button no 1 is pressed i e the S...

Page 13: ...ion 4 Station Board Connections for more information 2 7 SNMP Settings SNMP Simple Network Management Protocol is a protocol for centralizing the management of devices in IP networks Click Advanced Co...

Page 14: ...application is started Registration Successfull If enabled the station will send an SNMP trap when successfully registered in the SIP domain Registration Failed If enabled the station will send an SNM...

Page 15: ...tation may be set up to automatically poll configuration settings for SIP Call and SNMP from a TFTP server The IP address of this TFTP server can be obtained using DHCP procedures or be manually confi...

Page 16: ...uration procedure according to the set time interval 2 9 Advanced Configuration Options L L The configuration settings described in this section are not mandatory 2 9 1 VLAN VLAN Tagging or IEEE 802 1...

Page 17: ...ackets or all packets The option ONLY TAGGED should only be used against VLAN aware devices which tag packets Select ONLY TAGGED or ALL from the dropdown menu VLAN priority tag to switch priority Here...

Page 18: ...an authentication mechanism to devices wishing to attach to a LAN either establishing a point to point connection or preventing it if authentication fails L L STENTOFON SIP Stations support 802 1X as...

Page 19: ...ted If TTLS with PAP or PEAP with MSCHAPV2 is chosen a certificate must be uploaded to the station by clicking Browse The certificate must either be in Privacy Enhanced Mail PEM or Distinguished Encod...

Page 20: ...program must already be installed on your PC server with a defined IP address A free TFTP Server program can be downloaded from http tftpd32 jounin net Before starting the IP station upgrade procedur...

Page 21: ...rer may be set to hide known file extensions so the file may appear without the bin extension The name of the software image file has to be entered with the extension bin 3 3 Automatic Software Upgrad...

Page 22: ...enter the interval in minutes for checking updates The value must be between 1 and 999 and the default setting is 60 9 Click Save configuration for Updates The station will now contact the TFTP server...

Page 23: ...ide RJ45 connector for auxiliary equipment like IP camera PC or a second IP sta tion This port does not have an individual IP address It does not carry power for AUX equipment P3 6 pin plug on screw t...

Page 24: ...3 3 V The DAK keys and the DAK LEDs are programmed using IND commands in the Event Handler DAKs 1 to 4 and Soft keys 1 to 4 are used in current master stations Privacy on off is accomplished by pressi...

Page 25: ...nced 0dBm 600 ohm Pin 1 13 V max 500 mA to amplifier Pin 2 LSN negative line Pin 3 LSP positive line Pin 4 GND Pin 5 AMP_EN enable signal to amplifier Pin 6 AMP_ERR error signal from amplifier J10 Int...

Page 26: ...ossible reasons Station connected and registered to the SIP server Station not powered up if no other LEDs are active 5 2 Status LED LED3 Bicolor SMD LED on board component side Flashing 2 red 1 green...

Page 27: ...5 4 LAN LEDs These LEDs are on the LAN P1 and AUX P2 RJ45 ports Left LED Steady light Ethernet connection OK Flashing Ethernet traffic No light No Ethernet connection Right LED Light 100 Mbit Ethernet...

Page 28: ...ssword 1851 and press the Ok button 4 Navigate to Load defaults and press the Sel button 5 Press the Sel button again to load factory defaults The station will now restart with factory settings Statio...

Page 29: ...interval Required No If this parameter is not set in the file the function will be disabled Description This parameter enables the station to automatically look for software updates on the TFTP server...

Page 30: ...or fallback domain The IP address for the SIP domain server e g Asterisk or Cisco Call Manager should be defined in this section Values IP address given in regular dot notation e g 10 5 2 100 sip_doma...

Page 31: ...ired No Description If desired an IP address can be configured as a backup for speeddial_1 If the station has no connection to any of the configured SIP domains it can call directly to this IP address...

Page 32: ...value 0 9999 seconds 0 RTP timeout disabled remote_controlled_volume_override_mode Required No Description Acts as a simplex mode after first DTMF or is received from remote station Send DTMF to talk...

Page 33: ...lues IP address given in regular dot notation e g 10 5 2 100 For example with an allowed network of 10 5 2 0 and a network mask of 24 anyone with IP address 10 5 2 0 to 10 5 2 255 can access the MIB n...

Page 34: ...ription If enabled the station will send an SNMP trap if registration to the SIP domain failed Values 0 disabled 1 enabled enable_callConnect Required No Defaults to 1 Description If enabled the stati...

Page 35: ...ster_interval 600 call speeddial_1 1000 speeddial_1_ip 10 5 2 200 speeddial_2 1004 speeddial_2_ip 10 5 2 201 speeddial_3 1005 speeddial_3_ip 10 5 2 202 speaker_volume 4 mic_sensitivity 5 rtp_timeout 6...

Page 36: ...File The global configuration file has the same parameters as the device specific file except that the four parameters below will be ignored Hence it is recommended that the following parameters not b...

Page 37: ...37 SIP Master Stations Configuration A100K11211...

Page 38: ...g with Zenitel Any authorized reproduction in part or in whole must include this legend Zenitel All rights reserved The WEEE Directive does not legislate that Zenitel as a producer shall collect end o...