Document:
DOK11018en02
Author:
PM/CF
Date:
2020-09-24
Page:
12
of
21
WESTERSTRAND
Analogue
NTP
Clock
NTP
server
Select NTP servers, e.g.
192.168.1.237
or as an URL
ntp.se
. Also see
NTP
mode
=DHCP above Up
to five different NTP servers can be entered. If the first one fails it will automatically go to the next
one and so on.
Set
local
Time
Used for manual time setting.
Interval
Interval in seconds between NTP requests.
Reset
hands
at
time
out
This function is used to define how the clock should behave during a NTP synchronization alarm. See Alarm
timeout below. If the checkbox is checked the clock hands will go to 12 in case of synchronization alarm. If the box
is not checked, the clock continues to show time and uses its own built-in quartz oscillator as time reference.
Alarm
timeout.
Time in minutes before the NTP synchronization alarm is activated.
Timezone
Select country/time zone. A NTP server sends UTC time. The clock will correct this to local time. If Daylight
Saving Time (see below) is checked it will also and adjust for DST (Daylight Saving Time) automatically.
Daylight
Saving
Time
If checked then this timezone uses DST (Daylight Saving Time).
WESTERSTRAND
URFABRIK
AB
P.O. Box 133
Tel. +46 506 48000
Internet: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail: