8
ICX-AlphaCom ITSV-2 Video Configuration
The video is streamed in H.264 format over RTSP protocol from the TCIV+ camera to the
ITSV-2. The TCIV+ camera must have a static IP address.
●
Select
Account 1
>
Call Settings
● Check the
box
for
Start Video Automatically
●
Select
Value-added Service
>
Add
●
Service Type
: Select
Door System
from the dropdown box
●
Door System Type
: Select
Vingtor Stentofon
from the dropdown box
●
Display Name
: Name of Camera List
●
System Ringtone
: This will be used for calls from any station in the camera list. It is
possible to add several camera lists and use a different ringtone for each list.
● Click
Configure
for
System Number
to open the camera list
● Enter the directory number and camera URL of the TCIV+ station
System Number:
Directory Number of TCIV+ station
System Address:
rtsp://<user:password>@<TCIV+ IP address>:<port no.>/media?encoder=H264
Example:
rtsp://admin:[email protected]:554/media?encoder=H264
Note
: For TCIV units, System Address =
rtsp://admin:[email protected]:554/1/RTSP/video