7. Connector table 

Data connector (used connector FAP-5001-1202-0BF (Yamaichi)) 

DATA (CN1) 

I/O 

SIGNAL 

PIN 

SIGNAL 

I/O 

 

 

D0 

 

D0 

 

 

 

 

D1 

 

D1 

 

 

 

 

D2 

 

D2 

 

 

PORT 

D3 

 

D3 

PORT 

 

D4 

 

10 

D4 

 

 

 

D5 

11 

 

12 

D5 

 

 

 

 

D6 

13 

 

14 

D6 

 

 

 

 

D7 

15 

 

16 

D7 

 

 

 

 

D0 

17 

 

18 

D0 

 

 

 

 

D1 

19 

 

20 

D1 

 

 

 

 

D2 

21 

 

22 

D2 

 

 

PORT 

D3 

23 

 

24 

D3 

PORT 

 

D4 

25 

 

26 

D4 

 

 

 

D5 

27 

 

28 

D5 

 

 

 

 

D6 

29 

 

30 

D6 

 

 

 

 

D7 

31 

 

32 

D7 

 

 

IN 

LAH 

33 

 

34 

+5V 

 

 

OUT 

STB 

35 

 

36 

+5V 

 

 

OUT 

TRG 

37 

 

38 

+5V 

 

 

OUT 

CLR 

39 

 

40 

+5V 

 

 

 

 

(NC) 

41 

 

42 

GND 

 

 

 

 

(NC) 

43 

 

44 

GND 

 

 

 

 

(NC) 

45 

 

46 

GND 

 

 

 

 

(NC) 

47 

 

48 

GND 

 

 

 

 

(NC) 

49 

 

50 

GND 

 

 

 

Note) PIN 34, 36, 38, and 40 are (NC) in the former model ZS-6822 and +5V in the ZS-6822A. 

 

Note)  I/O  indicates  the  direction  between  signals  between  the  ZS-6822A  adapter  and  the 
digital I/O signal input/output device. 

IN   

: ZS-6822A ← External device 

OUT    : ZS-6822A → external device 
PORT    : Bi-directional data bus. 

You can switch IN/OUT by D command setting 

Summary of Contents for ZS-6822A Series

Page 1: ...1 ZS 6822A Series LAN DIO Adapter instruction manual 1st edition 2 13 37 Honmachi Fuchu City Tokyo 183 0027 Phone 81 42 368 2126 Fax 81 42 364 0067 URL https www zenisu co jp...

Page 2: ...ce Installer 6 5 How to install COM Port Redirector 9 5 1 Installation of COM Port Redirector 9 5 2 Virtual COM port setting 11 6 Operation 14 6 1 Transfer data method 14 6 2 Control Signals 15 6 3 In...

Page 3: ...on to data a control line is provided to synchronize with an external device 3 Specifications 3 1 Operating environment Equipment with LAN port 3 2 LAN Standard IEEE802 3 Media type 10BASE T or 100BAS...

Page 4: ...Small case low price Data connector 50 core flat cable 50 core flat cable Power supply DC4 75V to 5 25V 100mA or less DC4 75V to 5 25V 100mA or less Usage environment Temperature 0 C to 50 C Humidity...

Page 5: ...5 3 5 Appearance and dimensional drawing ZS 6822AP PC board type ZS 6822AS small case type Dimensional drawing ZS 6822AP ZS 6822AS...

Page 6: ...evice Installer If a warning message is displayed click OK ZS 6822A can be recognized the following screen will be displayed MAC address on the warranty card matches the displayed hardware address If...

Page 7: ...7 Enter the value of the address you wish to set in the IP Address section and click Next When the following screen appears click Assign...

Page 8: ...8 After a while the following screen is displayed and the setting is completed Click Finish It will be successful if the IP address has been changed correctly Quit Device Installer...

Page 9: ...s www lantronix com products com port redirector This chapter is not necessary when writing user application programs in TCP IP or UDP IP 5 1 Installation of COM Port Redirector Downloaded from our HP...

Page 10: ...tion and click the Next button Unless otherwise specified the installation destination can be left as is Click the Next button Installation will start Installation will start If the following screen a...

Page 11: ...11 Close button Click the OK button Installation is now complete 5 2 Virtual COM port setting From the start menu select Lantronix CPR Manager to start it A screen like the one below will appear...

Page 12: ...ill be added in Com Ports on the left side of the screen so select it and click Search For Devices the search is complete double click the item displayed in the Device List at the bottom of the screen...

Page 13: ...13 After completing the settings select Com Port Save Setting The following screen will be displayed so select Yes The settings are now complete Close and exit the application...

Page 14: ...de is used for data transfer and one character is converted to 4 bit binary code 4 bit binary LAN data 8 4 2 1 HEX 0 0 0 0 0 0 0 0 1 1 0 0 1 0 2 0 0 1 1 3 0 1 0 0 4 0 1 0 1 5 0 1 1 0 6 0 1 1 1 7 1 0 0...

Page 15: ...3 to D0 of port 4 6 2 Control Signals A control signal is provided to synchronize with the connected device Signal name signal direction explanation STB OUT The adapter completes receiving all data fr...

Page 16: ...data will remain in the missing area pulse output After receiving the data from the PC send the data to the port set for output Set data in 4 bit units in the order of high order and low order Output...

Page 17: ...ve logic of the port 6 4 1 R command function Data is read from all ports that are set as inputs For example if 4 input ports are set the R command will send 8 bytes of data from the ZS 6822A format R...

Page 18: ...at Dxxxx CR LF After D set port port port and port in this order x writes I for IN for input and O for OUT for output return value OK CR LF Setting complete NG CR LF Input output setting error setting...

Page 19: ...continuous output The pulse width at the time of pulse output is set by the P command format Ux CR LF x is a number 0 for continuous output and 1 for pulse output return value OK CR LF Setting comple...

Page 20: ...D6 29 30 D6 D7 31 32 D7 IN LAH 33 34 5V OUT STB 35 36 5V OUT TRG 37 38 5V OUT CLR 39 40 5V NC 41 42 GND NC 43 44 GND NC 45 46 GND NC 47 48 GND NC 49 50 GND Note PIN 34 36 38 and 40 are NC in the forme...

Page 21: ...nder normal conditions of use in accordance with the instruction manual and other notes In the following cases the product will be repaired for a fee even during the warranty period Malfunction or dam...