6-2

 

MODE switch

SW2

 

       

Set the communication protocol of RS-232C. 

ON(1)

OFF(0)

D1 D2 D3 D4 D5 D6 D7 D8

 

バッファメモリON/OFF

0:OFF 1:ON

RS-232Cデリミタ設定

D6 0:CR 1:LF
D7 0:D6が有効 1:ETX

未使用

 

パリティビット
ストップビット長  0:1bit 1:2bit
キャラクタ長      0:7bit 1:8bit

※ ※ ※ ※

※ ※

 

 

Parity bit 

D3 

D4 

Contents 

None 

Odd parity 

Even parity 

 
 

 

6-3 Baud rate switch

S4

) 

Initial setting 9600bps 

 

   

スイッチ番号

ボーレート(bps)

0

1,200

1

2,400

2

4,800

3

7,200

4

9,600

5

14,400

6

19,200

7

28,800

スイッチ番号

ボーレート(bps)

8

38,400

9

57,600

A

115,200

B

230,400

C

460,800

D

921,600

E

未使用

F

未使用

 

 

 

6-4 LED 

1

LED 

Name

 

Contents

 

POWER

 

Usable state

 

TX

 

Data sending to RS-232C

 

RS-232C 

error 

when 

flashing simultaneously.

 

RX

 

Data receiving from RS-232C

 

TLK

 

Data sending to GP-IB

 

GP-IB 

error 

when 

flshing simultaneously.

 

LSN

 

Data receiving from GP-IB

 

Buffer memory On/Off 

Delimiter of RS-232C 

0: OFF    1:ON 

D6 0: CR    1: LF 

D7 0: D6 is enable    1: ETX 

Unused

Parity

Stop bit length 

Character bit length 

0: 1bit    1: 2bit 

0: 7bit    1: 8bit 

Switch # 

Switch # 

Baud rate (bps) 

Baud rate (bps) 

Unused 

Unused 

Summary of Contents for ZS-6144AF

Page 1: ...A F Table of contents 1 Outline 1 2 Features 1 3 Specifications 1 4 Operation 3 5 Connecting cable 5 6 Functions 6 7 Appearance 8 8 Warranty 8 Zenisu Keisoku Inc Zip code 183 0027 2 13 37 Honmachi Fu...

Page 2: ...compared with the conventional ZS 6144F 3 Specifications 3 1 GP IB 1 Compliant with IEEE Std 488 SHI AHI T5 L3 SR1 RL0 PP0 DC0 DT0 CO 2 Connecter 57LE 20240 77C0 D35G CA 3 2 RS 232C 1 Communication me...

Page 3: ...ion Transmission data can be controlled by this signal RTS 7 It is output signal indicating whether data input output is possible to the partner side GND 5 All signal becomes 0V 10 Connecter DE 9P NR...

Page 4: ...ivable state data in the buffer memory is output to the RS 232C side In this case it is necessary both CTS and RTS is ON GP IB handshake is stopped when the data reception buffer memory becomes full W...

Page 5: ...is turned OFF data is output to the GP IB side RTS is turned ON again when the amount of data buffer memory is less than 4 K bytes 2 Flow control by X parameter This mode is effective when the other d...

Page 6: ...d the baud rate switch S4 3 For the connection of the cable refer to 5 Connection of RS 232C cable 4 Turn on the power to the RS 232C device ZS 6144AF GP IB controller in this order 5 The configuratio...

Page 7: ...on status of GP IB and RS 232C Note There is a product with SW1 4 bit dip switch mounted on the left side of SW2 but please use this switch in its initial state 6 1 ADR switch SW3 Specify the GP IB ad...

Page 8: ...9 200 7 28 800 bps 8 38 400 9 57 600 A 115 200 B 230 400 C 460 800 D 921 600 E F 6 4 LED 1 LED Name Contents POWER Usable state TX Data sending to RS 232C RS 232C error when flashing simultaneously RX...

Page 9: ...in accordance with instruction manual 2 It will be charged for extra in the following case even during warranty period Incorrect usage or failure or damage caused by carelessness Failure or damage ca...

Reviews: