4-2 SRQ 

   

SRQ is generated in the following cases when SRQ function is turned on with DIP 

switch (SW3). 

1)

 

When  the  amount  of  data  in  buffer  memory  is  exceeded  by  the  data  from 
RS-232C. 

2)

 

When the amount of data in buffer memory is exceeded by the data from GP-IB. 

3)

 

When RS-232C communication error occurs (parity error, framing error, overrun 
error). 

1

MSB

LSB

RQS

(1)が発生したとき'1'となります。

(2)が発生したとき'1'となります。

(3)が発生したとき'1'となります。

 

 
4-3

 

Flow control of RS-232C 

In  data  transfer  with  RS-232C,  it  is  possible  to  perform  flow  control  using  X 
parameter or control line to prevent loss of received data. 

1

Flow control by control line 

This  mode  is  effective  when  the  other  device  can  perform  flow  control  by  the 
control line. 
When data reception is possible, the RTS signal is turned ON, and RTS signal is 
turned OFF when the amount of data in buffer memory is exceeded. 
RTS is turned OFF, data is output to the GP-IB side. RTS is turned ON again 

when the amount of data buffer memory is less than 4 K bytes. 

2

Flow control by X parameter 

   

  This  mode  is  effective  when  the  other  device  can  perform  flow  control  by  X 

parameter. 

 

  It  transmits  an  X-OFF  code(13H)  and  requests  the  other  device  to  pause 
transmission when the amount of data buffer memory is exceeded by the data 
from the RS-232C interface device. 
ZS-6144AF transmits an X-ON(11H) code and requests transmission from the 
other device when the amount of data in buffer memory becomes 4 Kbytes or 
less after transmitting the X-OFF code. 

 

  Receiving an X-Off code from the RS-232C stops transmission and restarts 
transmission when receiving an X-ON code. 

 

4-4

 

Error message 

   

When  an  error  occurs,  operation  is  stopped  and  error  contents  are  notified  by 

blinking the LED on the front panel. 

   
        Note) Error will be cleared when power is turned on again. 

It becomes “1” when 1) occurs 

It becomes “1” when 2) occurs 

It becomes “1” when 3) occurs 

Summary of Contents for ZS-6144AF

Page 1: ...A F Table of contents 1 Outline 1 2 Features 1 3 Specifications 1 4 Operation 3 5 Connecting cable 5 6 Functions 6 7 Appearance 8 8 Warranty 8 Zenisu Keisoku Inc Zip code 183 0027 2 13 37 Honmachi Fu...

Page 2: ...compared with the conventional ZS 6144F 3 Specifications 3 1 GP IB 1 Compliant with IEEE Std 488 SHI AHI T5 L3 SR1 RL0 PP0 DC0 DT0 CO 2 Connecter 57LE 20240 77C0 D35G CA 3 2 RS 232C 1 Communication me...

Page 3: ...ion Transmission data can be controlled by this signal RTS 7 It is output signal indicating whether data input output is possible to the partner side GND 5 All signal becomes 0V 10 Connecter DE 9P NR...

Page 4: ...ivable state data in the buffer memory is output to the RS 232C side In this case it is necessary both CTS and RTS is ON GP IB handshake is stopped when the data reception buffer memory becomes full W...

Page 5: ...is turned OFF data is output to the GP IB side RTS is turned ON again when the amount of data buffer memory is less than 4 K bytes 2 Flow control by X parameter This mode is effective when the other d...

Page 6: ...d the baud rate switch S4 3 For the connection of the cable refer to 5 Connection of RS 232C cable 4 Turn on the power to the RS 232C device ZS 6144AF GP IB controller in this order 5 The configuratio...

Page 7: ...on status of GP IB and RS 232C Note There is a product with SW1 4 bit dip switch mounted on the left side of SW2 but please use this switch in its initial state 6 1 ADR switch SW3 Specify the GP IB ad...

Page 8: ...9 200 7 28 800 bps 8 38 400 9 57 600 A 115 200 B 230 400 C 460 800 D 921 600 E F 6 4 LED 1 LED Name Contents POWER Usable state TX Data sending to RS 232C RS 232C error when flashing simultaneously RX...

Page 9: ...in accordance with instruction manual 2 It will be charged for extra in the following case even during warranty period Incorrect usage or failure or damage caused by carelessness Failure or damage ca...

Reviews: