background image

                                                                                                                                  High Performance Output Filter – IP00 Series 

 

 

IM00168 

 

 

Installation Considerations 

 

 

CAUTION 

 

 

 

The High Performance Output Filter must be mounted on a vibration free surface, away from heat radiating 
sources. Do not mount the High Performance Output Filter in direct sunlight or on a hot surface. 
 

 

In selecting an enclosure for the High Performance Output Filter and any associated equipment, the total 
heat dissipation and resulting temperature rise in the enclosure must be considered. 

 

 

Attention is drawn to the potential for condensation in vulnerable environments. Additional precautions may 
be required for all enclosure types. 

 

 

The installation location and environment should provide for safe access and working conditions for service 
personnel. Do not mount the High Performance Output Filter in “confined spaces” 

2

 

 

 

Do not drill holes in the High Performance Output Filter. 

 

 

Do not allow metal shavings or any other conductive material to enter the enclosure or damage may result. 

 

 

Operating Considerations 

 

 

Zener recommends that the associated ZENER 8000 inverter be set for an audible switching frequency of 
2kHz.

 

 

                                                           

2

 Confined spaces are generally defined in Workplace Health and Safety (WH&S) regulations to mean spaces where 

special precautions are necessary to ensure a safe breathing atmosphere, or there is limited access for escape/rescue 
in case of emergency. 

Summary of Contents for IP00 Series

Page 1: ...ZENER VARIDRIVE SOLUTIONS ZENER 8000 High Performance Output Filter IP00 Series Instruction Manual Document IM00168 Printed 18 March 2019...

Page 2: ...rated in a safe manner It is the responsibility of the user to ensure compliance with all regulations and practices covering the installation and wiring of your ZENER 8000 The instruction manual shoul...

Page 3: ...s Explanation of Symbols 1 Receiving 1 Warnings 2 Performance 3 Mechanical Installation Information 4 Dimensions 4 Installation Considerations 5 Operating Considerations 5 Wiring Diagram 6 B Terminal...

Page 4: ......

Page 5: ...a common error in installation commissioning or operation Receiving Inspect the High Performance Output Filter for any shipping damage If any damage is found report it to the carrier immediately Acces...

Page 6: ...ment electrically mechanically or otherwise Modification may create safety hazards The High Performance Output Filter is designed to operate in series with an appropriately rated and otherwise suitabl...

Page 7: ...igh efficiency greater than 99 Eliminate the need for installing screened motor cables The permissible cable length1 between filter and motor is 500m Categories as defined in AS61800 3 are C1 limits a...

Page 8: ...x B X C Weight Mounting holes AHP0070 200 x 280 x 150 10 kg AHP2200 650 x 335 x 410 14mm Diameter 600mm x 250mm centres AHP3150 AHP3900 AHP4900 130 kg C A B Allow sufficient clearance for all cable t...

Page 9: ...ions may be required for all enclosure types The installation location and environment should provide for safe access and working conditions for service personnel Do not mount the High Performance Out...

Page 10: ...rnal trip input of the ZENER 8000 i If the High Performance Output Filter is not mounted adjacent to the inverter on the same mounting panel inside a metal enclosure screened power cable may be requir...

Page 11: ...for the protective earth conductor in the inverter installation Chassis A B models or 30A for models Chassis C D fitted with a fused terminal For supply protection cable size and electrical isolation...

Page 12: ...AHP3900 390A 429A AHP4900 490A 539A 630W Operation at higher Audible Frequency or at speeds 50Hz may require derating The filter is matched to the ZENER 8000 to allow for operation at temperatures ab...

Page 13: ......

Page 14: ...IMITED ACN 001 595 428 366 Horsley Rd Milperra NSW 2214 Australia PO Box 347 Milperra NSW 2144 Australia T 61 2 97953600 E sales zener net http www zener com au Zener Electric Pty Limited 2019 IM00168...