2.1 Usage

1.

Store product in a cool and dry place.

2.

Do not dispose of the product in heat or fire.

3.

Do not expose to moisture or submerge it in liquid.

4.

Do not use around strong static electricity or magnetic fields.

5.

Do not disassemble the product. Consult official Zendure channels when 
service or repair is required. Incorrect disassembly or reassembly may result 
in a risk of fire or injury to persons.

6.

When using the product, please strictly follow the operating environment 
temperature range specified in th

e

 user manual. If the temperature is too 

high, it may result in a fire or explosion; if the temperature is too low, the 
product performance may be severely reduced, or the product may cease to 
work.

7.

Do not block or obstruct the fan during use or place the product in an 
unventilated or dusty area.

8.

Ensure the product is not hit, dropped, or heavily vibrated. Securely fasten 
the product when transporting to avoid damage. If severely damaged, turn 
off the power source immediately and discontinue using the product.

9.

If you accidentally drop the product into water during use, please place it in 

a safe open area, and stay away from it until it is completely dry. The dried 
product should not be used again and should be properly disposed of 
according to the Disposal Guide section of this manual. 

10.

Only clean the ports with a dry cloth.

11.

Place on a flat surface to keep the product from falling over. If the product is 

overturned and severely damaged, turn it off immediately, place the battery 
in an open area, keep it away from people and combustibles, and dispose of 
it in

 

accordance with local laws and regulations.

12.

Keep out of reach of children and pets.

Temperature

Optimal Operating Temperature

Discharge Temperature

Charge Temperature

-

4°F to 1

40

°F

 (-20

°

C to 60

°

C)

3

2

°F to 11

0

°F

 (0

°

C to 45

°

C)

Storage Temperature

   

3

2

°F to 11

0

°F

 (0

°

C to 45

°

C)

59

°F to 

95

°F

 (15

°

C to 35

°

C)

2. Safety 

Guidelines

3

Summary of Contents for SuperBase Pro 2000

Page 1: ...SuperBase Pro 2000 User Manual...

Page 2: ...esponsible for being aware of all relevant regulations and using Zendure products in a way that is compliant Keep this manual for future reference Speci cations Safety Guidelines Getting Started 3 1 I...

Page 3: ...rted Supported Pure Sine Wave rated 2 000W surge 4 000W 100 120V 50 60Hz US JP version or 220 240V 50 60Hz Other versions USB C1 2 5 20V 100W Max Each USB C3 4 5 12V 20W Max Total 13 6V 10A 136W Max 1...

Page 4: ...eavily vibrated Securely fasten the product when transporting to avoid damage If severely damaged turn off the power source immediately and discontinue using the product 9 If you accidentally drop the...

Page 5: ...d due to product failure contact a professional battery recycling company for further processing 3 When disposing of secondary cells or batteries keep cells or batteries of different electrochemical s...

Page 6: ...echarging Time AC Frequency Power Ring AmpUp Mode PVMax GridFlow Cell Network Current Input Current Output AC On 3 2 Display Power Button Display ON OFF Power Ring Indicator The ring lls up as the bat...

Page 7: ...rn off after 1 minute of idle operation You can change this through the Zendure App When the product senses any load change or other changes to its operations the Display will automatically light up T...

Page 8: ...oad for 1 hour the AC Power will automatically turn o Please turn o AC Output power when not in use to reduce energy consumption DC Output Port With the device powered on brie y press the DC Power But...

Page 9: ...ces of product misuse including but not limited to charging with an unsuitable wall outlet circuit or power cable Zendure s GridFlow fast charge technology is speci cally for AC recharging offering 1...

Page 10: ...0W Solar Panels sold separately to charge the product please follow the instructions that come with the solar panels Before connecting a solar panel please ensure that the solar panel s output voltage...

Page 11: ...he cell network connection press and hold the DC Power Button for 3 seconds This will also activate GPS services You can manually turn off the cell network or GPS services in the Zendure App The signa...

Page 12: ...all sounds You can turn on Sleep Mode in the Zendure App Any changes to input power setting light sound or standby time of the display will deactivate Sleep Mode 3 11 Of ine UPS This product supports...

Page 13: ...the product Please gently wipe it with a dry soft clean cloth or paper towel 6 How should I store the product Before storing please turn off the product then store it in a dry ventilated place at room...

Page 14: ...arge for a long period shortens its lifespan SuperBase Pro mitigates the damage by putting the battery into hibernation mode To get the most out of the battery make sure it is about 60 charged before...

Reviews: