40
AH1001-001_v01
4
Gently clean the ultrasonic transducer, using the brush
supplied.
Regular cleaning reduces scaling.
PREVENTION AGAINST SCALE BUILD
Use cooled boiled water or distilled water. The water
●
temperature should not exceed 40°C.
At least once a week clean the water tank, humidifier
●
base and ultrasonic transducer.
Before using the humidifier, always pour fresh water into
●
the water tank.
If you do not use the humidifier for a long time, empty the
●
water tank and humidifier base, then wash all parts of the
humidifier, wipe and dry it.
The appliance is best stored in its original packaging.
●
DESCALING THE AIR HUMIDIFIER
1
Turn the appliance off by turning the control knob to
position
and disconnect the plug from the wall outlet.
2
Fill the container with 50 ml of vinegar (6% solution of
acetic acid) and 100 ml of water, and mix the whole. Pour
the resulting solution into the base of the humidifier for 30
minutes.
3
Empty the base of the humidifier (see section “DRAINING
THE BASE OF HUMIDIFIER”) and remove the scale with
a soft cloth.
4
Rinse the base of humidifier with clean water and dry it
with an absorbent cloth.
Be careful that no water gets into the fan outlet
(electrical components) because it may cause
serious damage to the humidifier.
If water gets into the fan outlet, contact your
service center.
DRAINING THE BASE OF HUMIDIFIER
1
Turn the appliance off by turning the control knob to
position
and disconnect the plug from the wall outlet.
2
Empty the base of the humidifier removing the
accumulated water (as shown in the photo).
Pouring water out in the wrong way may result
in water entering the outlet of the fan and
consequently cause serious damage to the
humidifier.
If water gets into the fan outlet, contact your
service center.
Cleaning and maintenance
The humidifier should be cleaned at least once
a week.
1
Before cleaning, turn the appliance off by turning the
control knob to position
and disconnect the plug from
the wall outlet.
2
Remove the water tank from the base of the humidifier,
lifting it up. Turn the water tank upside down.
3
Loosen the cap with the valve by turning it counter
clockwise and drain the water remaining in the tank.
Fill water tank with hot water and mild detergent
●
(dishwashing liquid), tightly screw the cap with the
valve and shake the tank several times. Empty the tank.
Repeat the operation several times by pouring water
into the tank without detergent until complete removal of
detergent residue.
Pay attention not to leave any cleaning solution
(detergent) in the water tank.
Empty the base of the humidifier removing the
●
accumulated water (see section “DRAINING THE BASE
OF HUMIDIFIER”).
C
E
Troubleshooting
Check the below listed comments and notices before requesting service.
PROBLEM
POSSIBLE CAUSE
REMEDY
The warning light does not work; there is no
haze and blowing.
The appliance is not plugged into a wall
outlet.
Plug the cord into an electrical outlet.
No power to the appliance.
Check electric circuit – fuses.
The appliance is turned on, the indicator light
is illuminated, no haze and blowing.
The water level in the tank for water has
fallen below the required.
Fill the water tank.
Too low humidification level is set.
Set a greater level of humidification.
Too much water in the base of humidifier.
Pour water from humidifier base, and then
tighten the cap with the valve tightly on the
water tank.
Summary of Contents for AH1001
Page 22: ...24 AH1001 001_v01 Zelmer 220 240 80 40 C RU...
Page 24: ...26 AH1001 001_v01 1 2 3 4 40 C E 1 2 3 LOW HIGH 4 a b 1 2 D C...
Page 25: ...27 AH1001 001_v01 12 1 2 50 6 100 30 3 4...
Page 26: ...28 AH1001 001_v01 PE...
Page 27: ...29 AH1001 001_v01 Zelmer C 220 240 80 40 BG...
Page 29: ...31 AH1001 001_v01 3 4 40 1 2 50 6 100 30 3 4 a b 1 2 1 2 C E...
Page 30: ...32 AH1001 001_v01 12...
Page 31: ...33 AH1001 001_v01 Zelmer 220 240 80 40 C UA...
Page 33: ...35 AH1001 001_v01 1 2 3 4 40 C 1 E 3 LOW HIGH 4 a b 1 2 C...