background image

Technical Services

Installation Instructions

CONTURA G2

Measuring Center

Summary of Contents for CONTURA G2

Page 1: ...Technical Services Installation Instructions CONTURA G2 Measuring Center ...

Page 2: ...ermissible air humidity 40 60 without condensation Sound level at installation site 90dB Max altitude above sea level for 100 125 V 3000 m for 220 240 V 2000 m Temperature Conditions for Operation of CMM The measuring uncertainty specified for your CMM can be guaranteed if 1 you use a measurement correction program and enter the workpiece and CMM temperatures as well as the temperature expansion c...

Page 3: ...erted by the CMM see the pertaining information in this bro chure 0 1 1 10 100 1000 0 10 20 30 40 50 X axis horizontal Y axis horizontal Z axis vertical Permissible foundation acceleration for Contura G2 w trigger probe and standard damping Acceleration values above the curve require an additional foundation Acceleration mm ss Frequency Hz ...

Page 4: ...0 10 20 30 40 50 X axis horizontal Y axis horizontal Z axis vertical Permissible foundation acceleration for Contura G2 measuring with standard damping Acceleration values above the curve require an additional foundation Acceleration mm ss Frequency Hz ...

Page 5: ... per taining national regulations also must be observed 2 3 Electric Power Supply Parameters To ensure trouble free data transmission between the CMM and the data station the line power supply must comply with the following specifications Line power supply Line voltage 1 N PE 100 110 115 120 125 230 240 VAC Max voltage fluctuations 10 Frequency 50 or 60 Hz Max frequency fluctuations 3 5 Max power ...

Page 6: ...e not obstructed by the base of the CMM 2 9 Transport Vehicles Please provide a forklift with sufficient carrying capacity and fork length to unload the packaged units and trans port them to the storage or installation site The loading capacities required of these vehicles are specified on the following pages All transport lanes and approaches should be kept open during the entire installation and...

Page 7: ...407 407 545 545 540 1986 2236 3176 4016 5997 1692 1951 2851 3358 5625 CONTURA G2 opt granite U profile Upper part X 1000 Y 1200 Z 600 Upper part X 1000 Y 1600 Z 600 Upper part X 1000 Y 2100 Z 600 2870 2845 3330 2265 2110 2110 2515 2515 2515 16 4 15 1 17 7 852 958 987 555 727 761 3092 3602 6084 2795 3372 5857 CONTURA G2 opt granite U profile Base X 1000 Y 1200 Z 600 Base X 1000 Y 1600 Z 600 Base X ...

Page 8: ... connection g CMM control connecting cable t Transport height without base X Y Z measuring range Length a Length b Length c Length t 700 700 600 1430 1525 920 1603 700 1000 600 1430 1830 1000 1200 600 1743 2030 1225 1000 1600 600 1743 2430 1000 2100 600 1743 2945 1756 4 CMM Installation Dimensions and Arrangement of Steel Plates 4 1 Installation Dimensions for CONTURA G2 all dimensions in mm scale...

Page 9: ... A to be installed by the customer e Telephone connection ISDN f CMM compressed air supply connection g CMM control connecting cable t Transport height without base CONTURA G2 with optional U profile X Y Z Measuring range Length a Length b Length c Length t 1000 1200 600 1743 2030 1200 1806 1000 1600 600 1743 2430 1000 2100 600 1743 2945 1959 Height of secured CMM assembly without pallet and witho...

Page 10: ...ding Admittance only for authorized personnel and may be entered only by persons who have received proper training operators min 1000 min 1000 min 1000 min 600 min 200 min 700 min 100 min 100 min 200 Floor marking or chain black and yellow d Controller c c The back door of the controller cabinet must be located at least 200mm away from the wall Moreover the air exchange with the surround ing envir...

Page 11: ...700 Y 1000 43 1 N cm2 CONTURA G2 X 1000 Y 1200 65 4 N cm2 X 1000 Y 1600 81 5 N cm2 X 1000 Y 2100 132 1 N cm2 CONTURA G2 w granite U table option X 1000 Y 1200 70 6 N cm2 X 1000 Y 1600 88 2 N cm2 X 1000 Y 2100 143 1 N cm2 Support A Cast iron plate Ø 150 included in delivery 4 4 Arrangement of the Steel Plates for Contura G2 The relative unevenness of the bearing surfaces must not exceed max 25mm 1 ...

Page 12: ... 4 700 237 700 127 89 1041 1 1 2 3 4 2 3 4 1321 1189 M12 16x Y X 256 456 656 856 Y grid position Bridge running surface Bridge drive X grid position 5 Dimensions of Granite Table and Fastening Hole Matrix 5 1 Measuring Table for Measuring Range of X 700 Y 700 Meas range ...

Page 13: ...8 744 8 944 8 1144 8 100 152 58 4 700 237 1000 127 89 1346 1 1 2 3 4 2 3 4 5 6 1626 1189 M12 24x Y X 256 456 656 856 Y grid position Bridge running surface Bridge drive X grid position 5 2 Measuring Table for Measuring Range of X 700 Y 1000 Meas range ...

Page 14: ...8 1144 8 1344 8 100 152 58 4 1000 237 1200 127 89 1545 1 1 2 3 4 5 6 2 3 4 5 6 7 1825 1492 M12 42x Y X 256 456 656 1056 856 1256 Y grid position Bridge running surface Bridge drive X grid position 5 3 Measuring Table for Measuring Range of X 1000 Y 1200 Meas range ...

Page 15: ...1344 8 1544 8 1744 8 100 152 58 4 1000 237 1600 127 89 1945 1 1 2 3 4 5 6 2 3 4 5 6 7 8 9 2225 1492 M12 54x Y X 256 456 656 1056 856 1256 Y grid position Bridge running surface Bridge drive X grid position 5 4 Measuring Table for Measuring Range of X 1000 Y 1600 Meas range ...

Page 16: ...4 8 1744 8 1944 8 2144 8 100 152 58 4 1000 237 2100 127 89 2464 1 1 2 3 4 5 6 2 3 4 5 6 7 8 9 2743 1494 M12 66x Y X 256 456 656 1056 856 1256 10 11 Y grid position Bridge running surface Bridge drive X grid position 5 5 Measuring Table for Measuring Range of X 1000 Y 2100 Meas range ...

Page 17: ... 1344 8 125 152 58 4 1000 237 1200 127 89 1545 1 1 2 3 4 5 6 2 3 4 5 6 7 1825 1492 M12 42x Y X 256 456 656 1056 856 1256 Y grid position Bridge running surface Bridge drive X grid position 5 6 Measuring Table with U Profile for Measuring Range of X 1000 Y 1200 Meas range ...

Page 18: ...544 8 1744 8 125 152 58 4 1000 237 1600 127 89 1945 1 1 2 3 4 5 6 2 3 4 5 6 7 8 9 2225 1492 M12 54x Y X 256 456 656 1056 856 1256 Y grid position Bridge running surface Bridge drive X grid position 5 7 Measuring Table with U Profile for Measuring Range of X 1000 Y 1600 Meas range ...

Page 19: ... 8 1944 8 2144 8 125 152 58 4 1000 237 2100 127 89 2464 1 1 2 3 4 5 6 2 3 4 5 6 7 8 9 2743 1494 M12 66x Y X 256 456 656 1056 856 1256 10 11 Y grid position Bridge running surface Bridge drive X grid position 5 8 Measuring Table with U Profile for Measuring Range of X 1000 Y 2100 Meas range ...

Page 20: ...Page 21 CONTURA G2 X 700 Y 1000 CONTURA G2 X 700 Y 700 CONTURA G2 X 1000 Y 1200 CONTURA G2 X 1000 Y 1600 CONTURA G2 X 1000 Y 2100 6 Cutout Patterns for Customer Floor Plan 6 1 Cutout Patterns for Contura G2 Scale 1 30 Controller ...

Reviews: