background image

4.

 Set the distance ring to the test distance according to the tables in the appendix.  

This setting must not be changed during the adjustment process. 

5.

 Set the aperture of the lens to full speed.

6.

 Obtain maximum image sharpness on the live view by varying the distance bet ween 

the test chart and the camera. 

7. 

Now remeasure the distance between the image plane mark on the camera body 

and the test chart (= the actual distance). 

  

 

8. 

If the distance has changed, the flange focal distance of the lens must be adjusted 

by using the colored shims. 

You find a list of tables in the appendix for each focal length to calculate  
the resultant change of the flange focal distance. 

9. 

 Now remove the lens from the camera.

 

  
 

10.

 Remove the EF mount and EF adapter ring (cf. section C 2–4). 

D. Adjusting the lens to your camera

As the flange focal distance varies from camera type to camera type, it is necessary to adjust 
the CP.2 lens to the camera used when changing the mount or camera model (=shimming). 
In order to perform this adjustment, Carl Zeiss provides shims in different thicknesses that are 
color coded. 

When the mount has been unscrewed, these shims can be placed in a groove in the lens 
barrel. Any possible combination of shims can be used to achieve the required thickness and 
therefore the required flange focal distance. The lens already contains shims when delivered. 

Carl Zeiss recommends that the camera is set to the usual standard settings  
(cf. works settings). You can obtain further details from the instruction manual  
of the camera you use. 

 

Procedure

In the following chapter we explain how to adjust your Compact Prime CP.2 to a DSLR camera. 

1. 

Fasten the Carl Zeiss test chart on a wall at the appropriate test distance (see tables  

on page 12 – 16; the test distance is depending on the focal length) and ensure that the 
illumination is bright and uniform.

2.

 Mount the camera and lens on a tripod and level the camera, making sure that the centre 

of the image is aligned with the centre of the Siemens star. 

3. 

Activate the live view of your camera, select the maximum magnification.

 

8

9

Summary of Contents for Compact Prime CP.2

Page 1: ...Compact Prime CP 2 Mount Change Instructions...

Page 2: ...nge a lens mount and the subsequent matching of your lens to a DSLR camera Proceed in the same sequences to switch to any other CP 2 mount General instructions The use of a T6 torque wrench with a tor...

Page 3: ...of the lens see section D in combination with your camera screw of the lens barrel 1 Remove the rear lens cap 2 Remove the four torx screws of the silver EF mount with a T6 torque wrench and place th...

Page 4: ...EF adapter ring in such a way that the blue dot on the mount has the same orientation as the ZEISS logo and the support bracket points to the serial number on the lens barrel 3 Please note the correct...

Page 5: ...hanging the mount or camera model shimming In order to perform this adjustment Carl Zeiss provides shims in different thicknesses that are color coded When the mount has been unscrewed these shims can...

Page 6: ...etermine the total thickness of the shims that are already installed in the lens groove Increase or decrease the total shim thickness according to the tables in the appendix by using a flat bladed scr...

Page 7: ...0 01 1500 0 00 5ft 0 0 00 1510 0 01 5ft 1 2 0 01 1520 0 02 5ft 1 0 02 1530 0 03 5ft 1 1 2 0 03 1540 0 04 5ft 2 0 04 Tables for adjusting the flange focal distance of Compact Prime CP 2 lenses All Com...

Page 8: ...980 0 02 3ft 11 0 02 990 0 01 3ft 11 1 2 0 01 1000 0 00 4ft 0 0 00 1010 0 01 4ft 1 0 01 1020 0 02 4ft 1 1 2 0 02 1030 0 03 4ft 2 0 03 1040 0 04 4ft 2 1 2 0 03 Meter distance scale Feet distance scale...

Page 9: ...mm Change of total washer thickness mm Object distance at best focus ft Change of total washer thickness mm 1987 0 04 6ft 11 4 8 0 03 1990 0 03 6ft 11 5 8 0 02 1993 0 02 6ft 11 6 8 0 02 1997 0 01 6ft...

Page 10: ...eable Mount Set MFT for CP 2 15 T2 9 CP 2 35 T1 5 SuSp CP 2 50 T1 5 SuSp CP 2 50 T2 1 CP 2 85 T1 5 SuSp or CP 2 85 T 2 1 1889 231 Interchangeable Mount Set MFT for CP 2 50 T2 1 or CP 2 85 T2 1 1889 23...

Page 11: ...446 Oberkochen Germany Phone 49 7364 20 6175 Fax 49 7364 20 4045 www zeiss com cine EN_10_070_712III Printed in Germany AW CZ VII 2012 Poo Subject to change in design and scope of delivery and as a re...