1. General 

 

1.1 Application 

 

This operating instruction is valid for the waste water lifting unit type E-ZW. 
Non-compliance with the operating instructions - in particular with the safety instructions - as well as non-manufacturer modification or use 
of non-original spare parts will result in loss of guarantee coverage. The manufacturer accepts no liability for damage or injury resulting from 
incorrect use of the equipment. 
These dewatering pumps are designed for delivering of well contaminated water with particulate materials from private household, industry 
and agriculture. The particle size must not exceed the mentioned size at ch. 1.3. 
This product may also pass as any other electrical equipment in cause of lacking electrical supply. If you may get any damages thereby, 
please calculate in accordance to the use an emergency power generator, a second pump and/ or a network independent alarm system. As the 
manufacturer we will be at your disposal after the buying for near information. In cause of defects or damages please contact your retail 
trader. 

 
Manufacturer

ZEHNDER Pumpen GmbH 

 

 

Zwönitzer Straße 19 

 

 

08344 Grünhain-Beierfeld 

 
Instruction last modified

: 03/2017 

 
 

1.2 Queries and Ordering 

 
For queries and orders please contact your authorised retail trader. 

 
 

1.3 Technical data 

 

Typ: 

E-ZW 50 A-2 

E-ZW 65 A 

E-ZW 80 A 

Input power P

1

 

380 W 

850 W 

850 W 

Motor power P

2

 

210 W 

430 W 

430 W 

Voltage / frequency 

230 V / 50 Hz 

Nominal current 

1.8 A 

3.7 A 

3.7 A 

Nominal speed 

2800 U/min 

Power cable 

10 m, 3 x 1 mm² 

max. capacity 

7,500 l/h 

9,500 l/h 

10,000 l/h 

max. head 

7,5 m 

14 m 

9 m 

max. particle size 

10 mm 

10 mm 

30 mm 

Pressure size 

G 1 1/4“ IG 

Weight 

6,5 kg 

8,0 kg 

9,0 kg 

Height over all 

340 mm 

358 mm 

372 mm 

Diameter 

175 mm 

max. liquid temperature 

40 °C (temporary

 

90 °C) 

max. dive in depth 

5 m 

Float switch 

yes 

 

Materials 

 
Pump body 

 

PP 

 

 

Impeller   

 

PA 6 

Outer housing 

 

Stainless steel 

 

Float switch 

 

PP 

Strainer   

 

Stainless steel 

 

Screws   

 

Stainless steel 

Motor housing 

 

Stainless steel 

 

Seals 

 

 

Carbon/ Ceramics 

Motor shaft 

 

Stainless steel 

 

Characteristics

 

 
 
 
 
 
 
 
 
 
 
 
 

GB

Summary of Contents for E-ZW 50 A-2

Page 1: ...Edelstahl Tauchpumpe Submersible pump stainless steel Pompe submersible E ZW EZW A EZW KS Betriebsanleitung Operating Instructions Manuel d utilisation GB F D ...

Page 2: ...lärung Hersteller ZEHNDER Pumpen GmbH Zwönitzer Straße 19 08344 Grünhain Beierfeld Produktbezeichnung Tauchmotorpumpe Typenkennzeichnung E ZW 50 A 2 E ZW 65 E ZW 80 Technische Daten Nennspannung 230 V 50 Hz Nennleistung 210 W 430 W 430 W Schutzklasse I Schutzgrad IP 68 Das die oben bezeichnete Produkt en entspricht den Anforderungen folgender Richtlinien 2014 35 EU Niederspannungsrichtlinie 2006 4...

Page 3: ...R Pumpen GmbH Zwönitzer Straße 19 08344 Grünhain Beierfeld Stand der Betriebsanleitung 03 2017 1 2 Anfragen und Bestellungen Anfragen und Bestellungen richten Sie bitte an Ihren Fach bzw Einzelhandel 1 3 Technische Daten Typ E ZW 50 A 2 E ZW 65 A E ZW 80 A Motorleistung P1 380 W 850 W 850 W Motorleistung P2 210 W 430 W 430 W Spannungsversorgung 230 V 50 Hz Nennstromaufnahme 1 8 A 3 7 A 3 7 A Nennd...

Page 4: ...tung Inspektion und Montage muß die entsprechende Qualifikation für diese Arbeiten aufweisen Verantwortungsbereich Zuständigkeit und die Überwachung des Personals müssen durch den Betreiber genau geregelt sein Liegen bei dem Personal nicht die notwendigen Kenntnisse vor so ist dieses zu schulen und zu unterweisen Dies kann falls erforderlich im Auftrag des Betreibers der Pumpe durch den Hersteller...

Page 5: ...eferten Anlage ist nur bei bestimmungsmäßiger Verwendung entsprechend Abschnitt 1 Allgemeines der Betriebsanleitung gewährleistet Die im Datenblatt angegebenen Grenzwerte dürfen auf keinen Fall überschritten werden Die unsachgemäße Verwendung der Unterwasserpumpe wie z B Förderung von Luft und explosiven Medien ist strengstens untersagt Auch ein automatisch arbeitendes Gerät wie z B eine Tauchpump...

Page 6: ...n frostfreien und dunklen Ort Die Motorwelle ist bei längerem Stillstand der Pumpe aller 2 Monate z B durch kurzes Einschalten der Pumpe zu drehen um ein Verkleben der Gleitringdichtung zu vermeiden Ersatzteile und Zubehör sind von Zehnder lieferbar Die Pumpen können in einer Zehnder Kundendienstwerkstatt überprüft werden Eine aktuelle Auflistung unserer Kundendienststellen finden Sie im Internet ...

Page 7: ...d verstopft oder verschlissen Reinigen Austauschen Druckleitung verstopft Schlauch geknickt Reinigen Knickstellen entfernen Bodensieb verstopft Reinigen 3 Fördermenge zu gering Pumpe ist nicht richtig entlüftet Luftblase im Gehäuse Bei Erstinbetriebnahme der Pumpe Druckleitung entlüften damit Wasser in das Pumpengehäuse gelangt 4 Fördermenge zu gering Druckleitung zu klein dimensioniert min Durchm...

Page 8: ...50 032 150 032 150 032 290 2 Kabelverschraubung PG 11 Ms 200 124 200 124 200 124 300 4 Ejot Schraube PT KA 40x10 WN 1412 800 030 800 030 800 030 301 4 Flachdichtung 8 5x3 3x1 0 100 911 100 911 100 911 305 1 Knickschutztülle 270014 270014 270014 310 1 O Ring 55x4 0 NBR 50 150 014 150 014 150 014 330 1 Schwimmerschalter L 0 5 m 270016 1 270016 1 270016 1 340 1 Anschlusskabel mit Stecker 270015 27001...

Page 9: ...t 14 Appendix Spare parts drawing 21 ______________________________________________________________________________________________________ EU Declaration of Conformity Manufacturer ZEHNDER Pumpen GmbH Zwönitzer Straße 19 08344 Grünhain Beierfeld Product name submersible motor pump Type designation E ZW 50 2 E ZW 65 E ZW 80 Technical specifications Rated voltage 230 V 50 Hz Power rating 210W 430W ...

Page 10: ...anufacturer we will be at your disposal after the buying for near information In cause of defects or damages please contact your retail trader Manufacturer ZEHNDER Pumpen GmbH Zwönitzer Straße 19 08344 Grünhain Beierfeld Instruction last modified 03 2017 1 2 Queries and Ordering For queries and orders please contact your authorised retail trader 1 3 Technical data Typ E ZW 50 A 2 E ZW 65 A E ZW 80...

Page 11: ... contents of the operating instructions are fully understood by the personnel This equipment may be used by children over 8 years of age and over as well as by persons with reduced physical sensory or mental abilities or lack of experience and knowledge when supervised or instructed regarding the safe use of the equipment and the resulting dangers Children must not play with the appliance Cleaning...

Page 12: ...units have a 10m power supply cable with plug for 230V 50Hz single phase Other voltages are possible on demand Please note the data printed on the type plate This pump must be connected to an earthed outlet Do not lower or lift the pump by means of the power cable A damaged power cable must be replaced immediately by a qualified electrician Danger of personal injury by electrical shock if operated...

Page 13: ...erson 6 Warranty This pump carries a 24 month manufacturer warranty The warranty period begins with the date of purchase by the end user Proof of purchase should be retained Within this period we will remove all kind of shortcoming due to failures of material or assembling It is up to us either to repair or to replace the pump This warranty does not cover damage cause by improper use or wear and t...

Page 14: ...asket 150 032 150 032 150 032 290 2 Screwed cable gland PG 11 Ms 200 124 200 124 200 124 300 4 Ejot Scew PT KA 40x10 WN 1412 800 030 800 030 800 030 301 4 Seal 8 5x3 3x1 0 100 911 100 911 100 911 305 1 Tension relief 270014 270014 270014 310 1 O Ring 55x4 0 NBR 50 150 014 150 014 150 014 330 1 Float switch 0 5 m 270016 1 270016 1 270016 1 340 1 Power cable with plug 270015 270015 270015 350 4 Cord...

Page 15: ...ments cause et élimination 19 10 Liste de pièces de rechange 20 Annexe Dessin des pièces de rechange 21 _________________________________________________________________________________________________________________ EU Déclaration de conformité fabricant ZEHNDER Pumpen GmbH Zwönitzer Straße 19 08344 Grünhain Beierfeld Nom du produit pompe submersible Type de marquage E ZW 50 2 E ZW 65 E ZW 80 Sp...

Page 16: ... On peut conclure la date de production du numéro de série tat du manuel d utilisation 03 2017 1 2 Demandes et commandes Veuillez adresser vos demandes et commandes à votre marchand spécialisé ou votre détaillant 1 3 Données techniques E ZW 50 A 2 E ZW 65 A E ZW 80 A Puissance d entrée P1 380 W 850 W 850 W Puissance d moteur P2 210 W 430 W 430 W Courant absorbé 1 6 A 3 7 A 3 7 A Voltage Fréquence ...

Page 17: ... de personnel et formation Le personnel pour le fonctionnement l entretien l inspection et de montage doit avoir les qualifications requises pour ce travail Les responsabilités la compétence et la supervision doivent être clairement définis par l opérateur Si le personnel ne disposent pas des connaissances nécessaires ils doivent être formés et instruits Cela peut le cas échéant agissant pour le c...

Page 18: ...arge des conséquences 2 8 Modes de fonctionnement inadmissibles La sécurité de travail de l unité livrée n est garantie que lors d une utilisation conformément à la section 1 Généralités du manuel d utilisation Les valeurs limites indiquées dans la fiche signalétique ne peuvent en aucun cas être dépassées Un appareil travaillant automatiquement comme p ex une pompe submersible ne peut également pa...

Page 19: ... choix avec le dépannage ou l échange de l unité Dommages en résultant de l usage inapproprié l usure roue et joint d étanchéité rotatif ou les contaminations sont exemptés de la garantie En outre le droit de garantie s annule en cas de travaux sauf les travaux mentionnés dans point 5 conduits à la pompe Dommages indirects à cause de la défaillance de la pompe ne sont pas acceptés 7 Enlèvement des...

Page 20: ...0 200 061 230 1 Condensateur 900134 279911 279911 240 1 Bornier 270027 270027 270027 250 1 Poignée 100 303 100 303 100 303 270 2 Vis pour poignée M5x8 A2 800 087 800 087 800 087 280 2 Joint d étanchéité en caoutchouc 150 032 150 032 150 032 290 2 Presse étoupe PG 11 Ms 200 124 200 124 200 124 300 4 Vis Ejot PT KA 40x10 WN 1412 800 030 800 030 800 030 301 4 Joint 8 5x3 3x1 0 100 911 100 911 100 911...

Page 21: ...21 Anhang Appendix Annexe Ersatzteilzeichnung Spare parts drawing Dessin des pièces de rechange E ZW 50 A 2 ...

Page 22: ...22 Ersatzteilzeichnung Spare parts drawing Dessin des pièces de rechange E ZW 65 A ...

Page 23: ...23 Ersatzteilzeichnung Spare parts drawing Dessin des pièces de rechange E ZW 80 A ...

Page 24: ...24 ______________________________________________________________________________________________________ 2017 ZEHNDER Pumpen GmbH ...

Reviews: