background image

6   

main screen. 

  The  programmed  ventilation  level  only  works  in 

the AUTO setting. 

  After 30 seconds, the ComfoControl will return to 

the main menu automatically. Your settings have 
now been saved. 

2.2.7 Temperature programme settings 

Use the ComfoControl to: 

•  Set a personal temperature programme. 

The  ComfoControl  comes  with  default  temperature  set-
tings.  If  so  required,  you  can  change  the  standard  tem-
perature  programme  to  meet  your  personal  temperature 
requirements.  Examples  include  weekday  and  weekend 
programmes. The temperature settings can be changed/
set as follows:  

1. 

Press

 “ 

 ”. 

2. 

Press

 “ 

 ”. 

3. 

Setting

 the temperature programme. 

–  

Select

 day: “Mo”, “Tu”, “We”, “Th”, “Fr”, “Sa” 

 

 or “Su”. 

–  

Select

 hour, 00:00 to 23:00, using “ ” or “ ”. 

–   If required, 

press

 the hour, for example: “

”, 

and then 

select

 the minutes using “

” or “

”, for 

example: “

”. 

–  

Select

  the  temperature  setting  (12  to  28  ˚C)  for 

each hour using “

” or “

”. 

If you wish to copy the programmed temperature setting 
to  the  following  (or  any  other)  day,  then  use  the  “ 

  ” 

function. This goes as follows: 
–  

Select

 the day, for example: “Mo”. 

–  

Press

 “ 

 ”; which changes to “ 

 ”. 

–  

Select

 the day to which the temperature setting is to 

be copied, for example: “Tu”. “Tu” now has the same 
temperature setting as “Mo”. 

4. 

Press

 “ 

 “ to confi rm the settings and return to the 

main screen. 

English

Summary of Contents for ComfoControl Luxe

Page 1: ...ComfoControl Luxe Handleiding Manual Manuel Anleitung comfosystems...

Page 2: ...ramme settings 5 2 2 7 Temperature programme settings 6 2 2 8 Time delay settings 7 2 2 9 Temperature correction settings 7 2 2 10 Screen settings 8 2 2 11 Language settings 8 2 3 System data 9 2 3 1...

Page 3: ...ed by the manu facturer unauthorised alterations and or modifications have been made to the unit 1 2 3 Liability The ComfoControl has been designed and produced for use in ventilation and cooling syst...

Page 4: ...automatically Your settings have now been saved 2 1 ComfoControl The ComfoControl regulates your ventilation and or cooling system The ComfoControl is mounted to the living room wall and communicates...

Page 5: ...the sum mer the active cooling can be activated while this is not desirable under normal winter conditions All the same if you wish to use active cooling in the winter then set the temperature to COOL...

Page 6: ...nformation about time delay then the time delay symbol will appear on the ComfoCon trol display in place of the ventilation volume buttons The extractor hood will be switched off after the programmed...

Page 7: ...et as follows 1 Press 2 Press 3 Setting the ventilation programme Select day Mo Tu We Th Fr Sa or Su Select hour 00 00 to 23 00 using or If required press the hour for example and then select the minu...

Page 8: ...e temperature settings can be changed set as follows 1 Press 2 Press 3 Setting the temperature programme Select day Mo Tu We Th Fr Sa or Su Select hour 00 00 to 23 00 using or If required press the ho...

Page 9: ...Time delay settings Use the ComfoControl to Programme a time delay for certain ventilation set tings The procedure is as follows 1 Press 2 Press 3 Press 4 Press or to choose between Time delay for th...

Page 10: ...njunction with a heating system thermostat we recommended synchronizing the temperature for both units on the display Use the ComfoControl to Programme a temperature correction relative to the re cord...

Page 11: ...of a malfunction the ComfoControl will dis play the corresponding code The ComfoControl display will show an A or an E fol lowed by a number What to do in the event of a malfunction In the event of a...

Page 12: ...g the materials in an environmentally friendly manner 3 For the Fitter This chapter describes how to fit the ComfoControl 3 1 Installation conditions In order to determine whether the ComfoControl can...

Page 13: ...Jumpers Right Relay 2 Open Comm Power Relay Relay Temp Sens Therm RS 485 12V DC 1 2 A B The temperature sensor specification is NTC 10 K optional The external temperature sensor is optional The indoor...

Page 14: ...nnected the OK will not appear on the screen and the re lated P menus will not be available 7 Using or select the required P menu e g P5 OPTIONS 8 Press OK to confirm the P menu selected 9 Using or se...

Page 15: ...e main menu The procedure is as follows 15 Press to return to the INSTALLATION MENU 16 Press again to return to the main screen After five minutes the ComfoControl will return automatically to the mai...

Reviews: