background image

2   

2.2  Using ComfoControl 

The ComfoControl is used for the following: 

Setting time and date. 

Setting the comfort temperature. 

Setting the ventilation volume. 

Switching the extractor hood on/off. 

Switching the supply and exhaust fan on/off. 

  If your ventilation system has a chimney cleaning 

function,  you  will  be  unable  to  switch  the  supply 
and exhaust fan on and off. 

Setting a personal ventilation programme. 

Setting a personal temperature programme. 

Setting  a  time  delay  for  a  number  of  ventilation  set-
tings. 

Setting a temperature correction. 

Setting the screen. 

Setting the language. 

A  concise  explanation  of  the  above  listing  is  given  in  the  para-
graphs below.

2.2.1  Time and date settings 

Use the ComfoControl to: 
•  Set the date and time. 

The procedure is as follows:  

1. 

Press

 "DAY AND TIME", here " 

 ". 

2. 

Press

 "   " or "

 

 

" to set the day. 

3. 

Press

left "

" or "

" to set the hour. 

4. 

Press

right "

" or "

" to set the minutes. 

5. 

Press

 "

 

 

" to confi rm the settings and return to the 

main screen. 

  After 30 seconds, the ComfoControl will return to 

the main menu automatically. Your settings have 
now been saved.

2.1   ComfoControl 

The ComfoControl regulates your ventilation and/or cooling system. 
•  The ComfoControl is mounted to the living room wall and communicates with your ventilation and/or cooling system. 

The list below briefl y explains what information the unit displays. 
The ComfoControl display is a touch screen. All settings can be accessed, adjusted and confi rmed simply by touching the screen.   

 

 

 

 

 

 

 

 

 

 

 

OPEN or CLOSE air supply

 

 

Current outside temperature

 

 

Automatic or manual 

ventilation activated

 

 

 

 

Actual temperature 

(programmable using 

MAN function)

 

 

OPEN or CLOSE 

air exhaust

 

 

Go to SYSTEM STATUS 

screen (for system data and 

error messages)

 

Time and date

 

Cooling system, 

reheater and/or 

extractor hood activated

 

 

 

Switch extractor hood 

ON or OFF

 

 

Go to SETTINGS screen 

(for ventilation and 

temperature settings)

 

 

Switch automatic 

or manual ventilation 

ON or OFF of 

 

 

 

System status 

and error messages  

Actual ventilation setting 

(programmable 

using MAN function)

 

 

Heat Recovery 

system activated

 

 

Bypass  

OPEN

 

[=       ] 

or 

bypass CLOSED [=      ]

 

       

Heat Recovery 

system active

 

 

 

If the function is not 

surrounded by a       ,

then it is not active

 

 

If the function is not 

surrounded by a       ,

then it is not active

 

English

Summary of Contents for ComfoControl Luxe

Page 1: ...ComfoControl Luxe Handleiding Manual Manuel Anleitung comfosystems...

Page 2: ...ramme settings 5 2 2 7 Temperature programme settings 6 2 2 8 Time delay settings 7 2 2 9 Temperature correction settings 7 2 2 10 Screen settings 8 2 2 11 Language settings 8 2 3 System data 9 2 3 1...

Page 3: ...ed by the manu facturer unauthorised alterations and or modifications have been made to the unit 1 2 3 Liability The ComfoControl has been designed and produced for use in ventilation and cooling syst...

Page 4: ...automatically Your settings have now been saved 2 1 ComfoControl The ComfoControl regulates your ventilation and or cooling system The ComfoControl is mounted to the living room wall and communicates...

Page 5: ...the sum mer the active cooling can be activated while this is not desirable under normal winter conditions All the same if you wish to use active cooling in the winter then set the temperature to COOL...

Page 6: ...nformation about time delay then the time delay symbol will appear on the ComfoCon trol display in place of the ventilation volume buttons The extractor hood will be switched off after the programmed...

Page 7: ...et as follows 1 Press 2 Press 3 Setting the ventilation programme Select day Mo Tu We Th Fr Sa or Su Select hour 00 00 to 23 00 using or If required press the hour for example and then select the minu...

Page 8: ...e temperature settings can be changed set as follows 1 Press 2 Press 3 Setting the temperature programme Select day Mo Tu We Th Fr Sa or Su Select hour 00 00 to 23 00 using or If required press the ho...

Page 9: ...Time delay settings Use the ComfoControl to Programme a time delay for certain ventilation set tings The procedure is as follows 1 Press 2 Press 3 Press 4 Press or to choose between Time delay for th...

Page 10: ...njunction with a heating system thermostat we recommended synchronizing the temperature for both units on the display Use the ComfoControl to Programme a temperature correction relative to the re cord...

Page 11: ...of a malfunction the ComfoControl will dis play the corresponding code The ComfoControl display will show an A or an E fol lowed by a number What to do in the event of a malfunction In the event of a...

Page 12: ...g the materials in an environmentally friendly manner 3 For the Fitter This chapter describes how to fit the ComfoControl 3 1 Installation conditions In order to determine whether the ComfoControl can...

Page 13: ...Jumpers Right Relay 2 Open Comm Power Relay Relay Temp Sens Therm RS 485 12V DC 1 2 A B The temperature sensor specification is NTC 10 K optional The external temperature sensor is optional The indoor...

Page 14: ...nnected the OK will not appear on the screen and the re lated P menus will not be available 7 Using or select the required P menu e g P5 OPTIONS 8 Press OK to confirm the P menu selected 9 Using or se...

Page 15: ...e main menu The procedure is as follows 15 Press to return to the INSTALLATION MENU 16 Press again to return to the main screen After five minutes the ComfoControl will return automatically to the mai...

Reviews: